An Improved Design of the MultiCal On-Site Calibration Device for Industrial Robots

被引:4
|
作者
Wan, Ziwei [1 ,2 ]
Zhou, Chunlin [1 ]
Lin, Zhaohui [3 ]
Yan, Huapeng [4 ]
Tang, Weixi [1 ]
Wang, Zhen [5 ]
Wu, Jun [1 ]
机构
[1] Zhejiang Univ, Coll Control Sci & Engn, Hangzhou 310063, Peoples R China
[2] Zhejiang Univ, Huzhou Inst, Lab Med Robots, Huzhou 313098, Peoples R China
[3] Zhejiang Univ, Sch Mech Engn, Hangzhou 310030, Peoples R China
[4] Univ Elect Sci & Technol China, Sch Automation Engn, Chengdu 611731, Peoples R China
[5] Huzhou Univ, Sch Engn, Huzhou 313000, Peoples R China
基金
中国国家自然科学基金;
关键词
calibration device; kinematic calibration; on-site calibration; industrial robot; accuracy measurement; KINEMATIC CALIBRATION;
D O I
10.3390/s23125717
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
MultiCal is an affordable, high-precision measuring device designed for the on-site calibration of industrial robots. Its design features a long measuring rod with a spherical tip that is attached to the robot. By restricting the rod's tip to multiple fixed points under different rod orientations, the relative positions of these points are accurately measured beforehand. A common issue with MultiCal is the gravity deformation of the long measuring rod, which introduces measurement errors into the system. This problem becomes especially serious when calibrating large robots, as the length of the measuring rod needs to be increased to enable the robot to move in a sufficient space. To address this issue, we propose two improvements in this paper. Firstly, we suggest the use of a new design of the measuring rod that is lightweight yet has high rigidity. Secondly, we propose a deformation compensation algorithm. Experimental results have shown that the new measuring rod improves calibration accuracy by 20% to 39%, while by using the deformation compensation algorithm, the accuracy increases by 6% to 16%. In the best configuration, the calibration accuracy is similar to that of a measuring arm with a laser scanner, producing an average positioning error of 0.274 mm and a maximum positioning error of 0.838 mm. The improved design is cost-affordable, robust, and has sufficient accuracy, making MultiCal a more reliable tool for industrial robot calibration.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Static calibration of industrial manipulators: Design of an optical instrumentation and application to SCARA robots
    Legnani, G
    Mina, C
    Trevelyan, J
    JOURNAL OF ROBOTIC SYSTEMS, 1996, 13 (07): : 445 - 460
  • [22] Static calibration of industrial manipulators: design of an optical instrumentation and application to SCARA robots
    Univ of Brescia, Brescia, Italy
    J Rob Syst, 7 (445-460):
  • [23] A DEVICE FOR AUTOMATIC ROBOT TOOL CENTER POINT (TCP) CALIBRATION ADJUSTMENT FOR THE ABB INDUSTRIAL ROBOTS
    Zwierzchowski, J.
    ENGINEERING MECHANICS 2017, 2017, : 1138 - +
  • [24] ON-SITE CALIBRATION SYSTEM FOR ISOLATION CURRENT TRANSFORMERS
    Mohns, E.
    2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 139 - 140
  • [25] Design of piezoelectric device compatible with pavement considering traffic: Simulation, laboratory and on-site
    Yuan, Huazhi
    Wang, Shuai
    Wang, Chaohui
    Song, Zhi
    Li, Yanwei
    APPLIED ENERGY, 2022, 306
  • [26] On-site calibration system for trace humidity sensors
    Huebert, Thomas
    Tiebe, Carlo
    Detjens, Marc
    Majewski, Jacek
    MEASUREMENT, 2016, 91 : 251 - 257
  • [27] Measurement equipment for on-site calibration of energy meters
    Delle Femine, Antonio
    Gallo, Daniele
    Landi, Carmine
    Luiso, Mario
    2007 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2007, : 975 - 980
  • [28] PORTABLE INSTRUMENTS TO PORTABLE WORKSHOPS FOR ON-SITE CALIBRATION
    BOND, A
    CONTROL AND INSTRUMENTATION, 1978, 10 (06): : 31 - &
  • [29] On-site surrogates for large-scale calibration
    Huang, Jiangeng
    Gramacy, Robert B.
    Binois, Mickael
    Libraschi, Mirko
    APPLIED STOCHASTIC MODELS IN BUSINESS AND INDUSTRY, 2020, 36 (02) : 283 - 304
  • [30] On-site calibration evaluation procedures for WIM systems
    Washington State Univ, Pullman, United States
    Transp Res Rec, 1536 (1-11):