Overt speech decoding from cortical activity: a comparison of different linear methods

被引:1
|
作者
Le Godais, Gael [1 ]
Roussel, Philemon [1 ]
Bocquelet, Florent [1 ]
Aubert, Marc [1 ]
Kahane, Philippe [1 ,2 ]
Chabardes, Stephan [1 ,3 ]
Yvert, Blaise [1 ]
机构
[1] Univ Grenoble Alpes, Grenoble Inst Neurosci, INSERM, U1216, Grenoble, France
[2] CHU Grenoble Alpes, Dept Neurol, Grenoble, France
[3] Univ Grenoble Alpes, CHU Grenoble Alpes, Clinatec, Grenoble, France
来源
基金
欧盟地平线“2020”;
关键词
decoding; ECoG; brain-computer interface; linear methods; speech prostheses; intracranial recordings; articulatory synthesis; HUMAN SENSORIMOTOR CORTEX; ORGANIZATION;
D O I
10.3389/fnhum.2023.1124065
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
IntroductionSpeech BCIs aim at reconstructing speech in real time from ongoing cortical activity. Ideal BCIs would need to reconstruct speech audio signal frame by frame on a millisecond-timescale. Such approaches require fast computation. In this respect, linear decoder are good candidates and have been widely used in motor BCIs. Yet, they have been very seldomly studied for speech reconstruction, and never for reconstruction of articulatory movements from intracranial activity. Here, we compared vanilla linear regression, ridge-regularized linear regressions, and partial least squares regressions for offline decoding of overt speech from cortical activity. MethodsTwo decoding paradigms were investigated: (1) direct decoding of acoustic vocoder features of speech, and (2) indirect decoding of vocoder features through an intermediate articulatory representation chained with a real-time-compatible DNN-based articulatory-to-acoustic synthesizer. Participant's articulatory trajectories were estimated from an electromagnetic-articulography dataset using dynamic time warping. The accuracy of the decoders was evaluated by computing correlations between original and reconstructed features. ResultsWe found that similar performance was achieved by all linear methods well above chance levels, albeit without reaching intelligibility. Direct and indirect methods achieved comparable performance, with an advantage for direct decoding. DiscussionFuture work will address the development of an improved neural speech decoder compatible with fast frame-by-frame speech reconstruction from ongoing activity at a millisecond timescale.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Comparison of classification methods for detecting emotion from Mandarin speech
    Pao, Tsang-Long
    Chen, Yu-Te
    Yeh, Jun-Heng
    IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2008, E91D (04): : 1074 - 1081
  • [42] Comparison of different non-linear evaluation methods in thermal analysis
    Anderson, H. L.
    Kemmler, A.
    Strey, R.
    Thermochimica Acta, 271
  • [43] Comparison of different methods for non-linear diffusive shock acceleration
    Caprioli, D.
    Kang, Hyesung
    Vladimirov, A. E.
    Jones, T. W.
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2010, 407 (03) : 1773 - 1783
  • [44] Comparison of different non-linear evaluation methods in thermal analysis
    Anderson, HL
    Kemmler, A
    Strey, R
    THERMOCHIMICA ACTA, 1996, 271 : 23 - 29
  • [45] COMPARISON OF DIFFERENT ASSAY-METHODS FOR DETERMINATION OF ELASTASE ACTIVITY
    MANIKASAIZONOU, B
    BOSTANCIOGLU, K
    MEALET, C
    FAVREBONVIN, G
    WALLACH, JM
    ANALYTICAL LETTERS PART B-CLINICAL AND BIOCHEMICAL ANALYSIS, 1985, 18 (07): : 901 - 913
  • [46] Comparison of different methods for evaluation of the proliferative activity in breast cancer
    Mink, D
    VillenaHeinsen, C
    Tossounidis, I
    Schmidt, W
    GYNAKOLOGISCH-GEBURTSHILFLICHE RUNDSCHAU, 1995, 35 : 53 - 56
  • [47] A comparison of different methylene blue methods for assessing surface activity
    Brennan, MJ
    Kilmartin, T
    Lawless, A
    Mulry, B
    MECHANICAL TESTS FOR BITUMINOUS MATERIALS: RECENT IMPROVEMENTS AND FUTURE PROSPECTS, 1997, : 517 - 523
  • [48] A comparison of different methods to assess the hemorrhagic activity of Bothrops venoms
    de Roodt, AR
    Dolab, JA
    Dokmetjian, JC
    Litwin, S
    Segre, L
    Vidal, JC
    TOXICON, 2000, 38 (06) : 865 - 873
  • [49] COMPARISON OF DIFFERENT METHODS OF DETERMINING PROTEOLYTIC ACTIVITY OF GASTRIC JUICE
    SABSAI, BI
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE,USSR, 1962, 52 (09): : 1092 - &
  • [50] COMPARISON OF DIFFERENT METHODS FOR TESTING THE POZZOLANIC ACTIVITY OF FLY ASHES
    SYBERTZ, F
    FLY ASH, SILICA FUME, SLAG, AND NATURAL POZZOLANS IN CONCRETE, VOL 1-2, 1989, 114 : 477 - 497