Refractive Results after Implantation of Toric Intraocular Lenses Using the Zeiss Callisto System

被引:0
|
作者
Raemy, Kenji [1 ,3 ]
Scherrer, Mark [2 ]
Sturmer, Jorg Peter Egon [2 ]
机构
[1] Univ Zurich, Med Fak, Zurich, Switzerland
[2] Kantonsspital Winterthur, Augenklin, Winterthur, Switzerland
[3] Ifang 3, CH-8307 Effretikon, Switzerland
关键词
cataract; astigmatism; toric IOL; Zeiss Callisto; IMAGE-GUIDED SYSTEM; ALIGNMENT ACCURACY; ASTIGMATISM; OUTCOMES; SURGERY; MARKING;
D O I
10.1055/a-2013-2466
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background For cataract patients with astigmatism, the insertion of a toric intraocular lens is a safe and effective method to achieve emmetropia. The exact alignment of the lens along the calculated axis is essential for effective correction of astigmatism. The purpose of this study is to evaluate our own data using descriptive statistics. The primary focus is on the refractive outcome and thus the verification of the alignment accuracy of toric IOLs with the Zeiss Callisto system. Patients and Methods The study evaluated a total of 106 eyes of 72 patients who underwent cataract surgery with implantation of a toric intraocular lens at our hospital between January 2019 and December 2020. Preoperative biometry and intraoperative marking of the implantation axis was performed using the Zeiss Callisto system. Postoperative controls were performed after one day, one week and 4 weeks, either at our hospital or by the referring ophthalmologist. For the analysis, only the data of the 4-week control were used. Results In 64 eyes (60%), a Zeiss AT Torbi 709M or MP and in 42 eyes (40%) a PhysIOL Ankoris toric yellow IOL were implanted. In 46 eyes, postoperative uncorrected visual acuity was not recorded. Of the remaining 60 eyes, the mean postoperative uncorrected visual acuity was 0.07 +/- 0.12 logMAR. Postoperative uncorrected visual acuity >= 1.0 (decimal) was achieved in 48% of the eyes and visual acuity >= 0.6 (decimal) in 92%. The postoperative cylinder averaged - 0.65 +/- 0.53 D. The cylinder of the target refraction was - 0.45 +/- 0.39 D on average. The mean of the absolute value of the postoperative cylinder minus the cylinder of the target refraction was 0.42 +/- 0.32 D. Conclusions The Zeiss Callisto system is an effective tool to align toric intraocular lenses.
引用
收藏
页码:421 / 425
页数:5
相关论文
共 50 条
  • [41] Prediction of postoperative refractive astigmatism before toric intraocular lens implantation
    Kawahara, Atsushi
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [42] Results of higher power toric intraocular lens implantation
    Hoffmann, Peter C.
    Auel, Sebastian
    Huetz, Werner W.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (08): : 1411 - 1418
  • [43] Outcome of toric intraocular lenses implanted in eyes with previous corneal refractive surgery
    Cao, Danmin
    Wang, Li
    Koch, Douglas D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (04): : 534 - 539
  • [44] Comparing the Zeiss Callisto Eye and the Alcon Verion Image Guided System Toric Lens Alignment Technologies
    Hura, Arjan S.
    Osher, Robert H.
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (07) : 482 - +
  • [45] Comparison of Refractive Stability After Non-toric Versus Toric Intraocular Lens Implantation During Cataract Surgery REPLY
    Jeon, Jei Hun
    Rim, Hyung Taek Tyler
    Seo, Kyoung Yul
    Kim, Eung Kweon
    Kim, Tae-Im
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (04) : 919 - 919
  • [47] Visual acuity improvements after implantation of toric intraocular lenses in cataract patients with astigmatism: a systematic review
    Agresta, Blaise
    Knorz, Michael C.
    Donatti, Christina
    Jackson, Daniel
    BMC OPHTHALMOLOGY, 2012, 12
  • [48] Visual acuity improvements after implantation of toric intraocular lenses in cataract patients with astigmatism: a systematic review
    Blaise Agresta
    Michael C Knorz
    Christina Donatti
    Daniel Jackson
    BMC Ophthalmology, 12
  • [49] Bilateral acute severe intraocular pressure elevation requiring filtration surgery after implantation of toric Artisan phakic intraocular lenses
    Toh, Tze'Yo
    Nguyen, Dan Q.
    Ruddle, Jonathan B.
    Crowston, Jonathan G.
    Coote, Michael A.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 (02): : 212 - 213
  • [50] Comparison of the Astigmatic Power of Toric Intraocular Lenses Using Three Toric Calculators
    Park, Hyun Ju
    Lee, Hun
    Woo, Young Jae
    Kim, Eung Kweon
    Soo, Kyoung Yul
    Kim, Ha Yan
    Kim, Tae-im
    YONSEI MEDICAL JOURNAL, 2015, 56 (04) : 1097 - 1105