Performance of steel beam with welded top-seat angle connections at elevated temperatures

被引:2
|
作者
Rezaeian, Abbas [1 ]
Mansoori, Mona [1 ]
Khajehdezfuly, Amin [1 ]
机构
[1] Shahid Chamran Univ Ahvaz, Dept Civil Engn, Ahvaz, Iran
关键词
Fire resistance; Steel beam; Welded connection; Top-seat angle; Finite element modeling; Elevated temperature; END-PLATE CONNECTIONS; COLUMN CONNECTIONS; FIRE RESPONSE; BEHAVIOR; ASSEMBLIES; SURVIVABILITY; STRATEGIES; RESISTANCE; INCREASE; FRAMES;
D O I
10.1108/JSFE-07-2022-0026
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
PurposeTop-seat angle connection is known as one of the usual uncomplicated beam-to-column joints used in steel structures. This article investigates the fire performance of welded top-seat angle connections.Design/methodology/approachA finite element (FE) model, including nonlinear contact interactions, high-temperature properties of steel, and material and geometric nonlinearities was created for accomplishing the fire performance analysis. The FE model was verified by comparing its simulation results with test data. Using the verified model, 24 steel-framed top-seat angle connection assemblies are modeled. Parametric studies were performed employing the verified FE model to study the influence of critical factors on the performance of steel beams and their welded angle joints.FindingsThe results obtained from the parametric studies illustrate that decreasing the gap size and the top angle size and increasing the top angles thickness affect fire behavior of top-seat angle joints and decrease the beam deflection by about 16% at temperatures beyond 570 degrees C. Also, the fire-resistance rating of the beam with seat angle stiffener increases about 15%, compared to those with and without the web stiffener. The failure of the beam happens when the deflections become more than span/30 at temperatures beyond 576 degrees C. Results also show that load type, load ratio and axial stiffness levels significantly control the fire performance of the beam with top-seat angle connections in semi-rigid steel frames.Originality/valueDevelopment of design methodologies for these joints and connected beam in fire conditions is delayed by current building codes due to the lack of adequate understanding of fire behavior of steel beams with welded top-seat angle connections.
引用
收藏
页码:113 / 146
页数:34
相关论文
共 50 条
  • [41] FIRE RESISTANCE PERFORMANCE OF CELLULAR STEEL BEAM (CSB) AT ELEVATED TEMPERATURES
    Zakwan, Fariz Aswan Ahmad
    Krishnamoorthy, Renga Rao
    Ibrahim, Azmi
    Ismail, Abdul Manaff
    JURNAL TEKNOLOGI, 2015, 76 (09): : 97 - 101
  • [42] Performance analysis of novel-top-seat angle and web double-bending-angle connections against progressive collapse
    Meng, Bao
    Li, Chenzhou
    Zhong, Weihui
    Wen, Junlong
    Du, Qiangqiang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 220
  • [43] Design tables for top- and seat-angle with double web-angle connections
    Kim, Y
    Chen, WF
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 1998, 35 (02): : 50 - 75
  • [44] Design tables for top- and seat-angle with double web-angle connections
    Kim, Yosuk
    Chen, Wai-Fah
    Engineering Journal, 35 (02): : 50 - 75
  • [45] Top-and-seat and web angle connections: prediction via mechanical model
    Pucinotti, R
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2001, 57 (06) : 661 - 694
  • [46] Seismic Performance of Welded Steel Beam-to-Column Connections with Initial Weld Defects
    Jiaming Li
    Haoran Yu
    Weibin Li
    Weijia Cheng
    International Journal of Steel Structures, 2022, 22 : 566 - 584
  • [47] Seismic Performance of Welded Steel Beam-to-Column Connections with Initial Weld Defects
    Li, Jiaming
    Yu, Haoran
    Li, Weibin
    Cheng, Weijia
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2022, 22 (02) : 566 - 584
  • [48] Cyclic mechanical model of semirigid top and seat and double web angle connections
    Pucinotti, R
    STEEL AND COMPOSITE STRUCTURES, 2006, 6 (02): : 139 - 157
  • [49] Cyclic load tests and analysis of bolted top-and-seat angle connections
    Garlock, MM
    Ricles, JM
    Sause, R
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2003, 129 (12): : 1615 - 1625
  • [50] SINGLE-ANGLE WELDED-BOLTED BEAM CONNECTIONS
    LIPSON, SL