摘要
Due to an increasing demand for electric power and changes in the typology of loads, stability has become a major concern in power systems. As the system stability is directly related to the response of the connected generator, recent research has focused on enhancing generators' stability and improving their response to load variations. This study focuses on adding another excitation winding on to the q-axis, perpendicular to the conventional excitation winding on the d-axis, to control both active and reactive power. This paper studies and compares the performance of the dual excitation synchronous generator (DESG) to conventional synchronous generators. The mathematical equations are derived, and a mathematical model is then developed. The experimental tests have been conducted using a laboratory model consisting of a two-phase synchronous generator driven by a DC motor with different loads. The obtained results and radial diagrams for the different loading types are presented and evaluated. Therefore, a new approach has been designed to connect the DESG directly to the power grid without any electronic components using a special coupling that works in one direction. Two perpendicular excitation coils, d and q, were formed from the existing coils, and the tests were carried out on all loads, ensuring that the revolving angle (i.e., the stability angle phi) was fixed. The results show that the proposed method offers significant cost savings, potentially amounting to 15-20% of the unit price. The experimental results confirm that the DESG significantly improves the generator stability by maintaining a constant rotor angle delta, which requires using an automatic angle regulator (AAR) in addition to the conventional automatic voltage regulator (AVR).
引用
收藏
页数:24
相关论文
共 50 条
  • [31] The synchronous generator digital excitation regulator
    Ma Linlin
    Wang Bing
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [32] The Connection to the Electrical Grid of the Synchronous Generator
    Michailidis, P.
    Ondrusek, C.
    12TH INTERNATIONAL CONFERENCE ON LOW VOLTAGE ELECTRICAL MACHINES, 2012, : 71 - 74
  • [33] Application of new POSICAST control method to synchronous generator excitation system
    Ghorbani, Hamidreza
    Monadi, Mehdi
    Ghorbani, Amir
    JOURNAL OF POWER TECHNOLOGIES, 2018, 98 (04): : 336 - 344
  • [34] The Development of a New Full-Wave Induced Excitation Synchronous Generator
    Wei, Bei
    Wang, Xiuhe
    Zhong, Hui
    ADVANCES IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 614-615 : 1240 - 1243
  • [35] The Design And The Control Principle Analysis Of A New Hybrid Excitation Synchronous Generator
    Guo Zhen
    Tian Yanbing
    Fu Xinhe
    2012 INTERNATIONAL CONFERENCE ON INDUSTRIAL CONTROL AND ELECTRONICS ENGINEERING (ICICEE), 2012, : 1914 - 1916
  • [36] Discriminating Between Loss of Excitation and Power Swings in Synchronous Generator Based on ANN
    Barakat, Zeina A.
    Hajjar, Ammar A.
    Kherbek, Tarek
    Alhelou, Hassan Haes
    JOURNAL OF CONTROL AUTOMATION AND ELECTRICAL SYSTEMS, 2019, 30 (04) : 545 - 556
  • [37] Discriminating Between Loss of Excitation and Power Swings in Synchronous Generator Based on ANN
    Zeina A. Barakat
    Ammar A. Hajjar
    Tarek Kherbek
    Hassan Haes Alhelou
    Journal of Control, Automation and Electrical Systems, 2019, 30 : 545 - 556
  • [38] The Control Strategy of a Hybrid Excitation Synchronous Generator in Wind Power Generation Systems
    Yang, Yong
    Yuan, Yi
    ADVANCED SCIENCE LETTERS, 2011, 4 (4-5) : 1381 - 1386
  • [39] Adjustment of Active and Reactive Power of Synchronous Generator in Grid-connected Operation
    Sun, Huiqiang
    2019 5TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION, 2020, 440
  • [40] Analysis of Wind Driven Permanent Magnet Synchronous Generator for Power Grid System
    Raj, R. Essaki
    Vasudevan, N.
    Srinivasan, S.
    Abirami, T.
    Pandian, R.
    Gnanavel, C.
    Parkunam, N.
    Srinivasan, R.
    Hurissa, Dejene
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2025, 2025 (01):