Estimation of a Machine Learning-Based Decision Rule to Reduce Hypoglycemia Among Older Adults With Type 1 Diabetes: A Post Hoc Analysis of Continuous Glucose Monitoring in the WISDM Study

被引:0
|
作者
Kahkoska, Anna R. [1 ,2 ]
Shah, Kushal S. [3 ]
Kosorok, Michael R. [3 ]
Miller, Kellee M. [4 ]
Rickels, Michael [5 ]
Weinstock, Ruth S. [6 ]
Young, Laura A. [7 ]
Pratley, Richard E. [8 ]
机构
[1] Univ N Carolina, Dept Nutr, 2205A McGavran Greenberg Hall, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, UNC Ctr Aging & Hlth, Chapel Hill, NC 27599 USA
[3] Univ N Carolina, Dept Biostat, Chapel Hill, NC 27599 USA
[4] Jaeb Ctr Hlth Res, Tampa, FL USA
[5] Univ Penn, Rodebaugh Diabet Ctr, Perelman Sch Med, Philadelphia, PA 19104 USA
[6] SUNY Upstate Med Univ, Div Endocrinol Diabet & Metab, Syracuse, NY 13210 USA
[7] Univ N Carolina, Div Endocrinol & Metab, Chapel Hill, NC 27599 USA
[8] AdventHlth Translat Res Inst, Orlando, FL USA
来源
基金
美国国家卫生研究院;
关键词
type; 1; diabetes; older adults; continuous glucose monitoring; hypoglycemia; heterogeneous treatment effects; precision medicine; CONSENSUS; MEDICINE; METRICS;
D O I
10.1177/19322968221149040
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The Wireless Innovation for Seniors with Diabetes Mellitus (WISDM) study demonstrated continuous glucose monitoring (CGM) reduced hypoglycemia over 6 months among older adults with type 1 diabetes (T1D) compared with blood glucose monitoring (BGM). We explored heterogeneous treatment effects of CGM on hypoglycemia by formulating a data-driven decision rule that selects an intervention (ie, CGM vs BGM) to minimize percentage of time Method: The precision medicine analyses used data from participants with complete data (n = 194 older adults, including those who received CGM [n = 100] and BGM [n = 94] in the trial). Policy tree and decision list algorithms were fit with 14 baseline demographic, clinical, and laboratory measures. The primary outcome was CGM-measured percentage of time spent in hypoglycemic range (<70 mg/dL), and the decision rule assigned participants to a subgroup reflecting the treatment estimated to minimize this outcome across all follow-up visits. Results: The optimal decision rule was found to be a decision list with 3 steps. The first step moved WISDM participants with baseline time-below range >1.35% and no detectable C-peptide levels to the CGM subgroup (n = 139), and the second step moved WISDM participants with a baseline time-below range of >6.45% to the CGM subgroup (n = 18). The remaining participants (n = 37) were left in the BGM subgroup. Compared with the BGM subgroup (n = 37; 19%), the group for whom CGM minimized hypoglycemia (n = 157; 81%) had more baseline hypoglycemia, a lower proportion of detectable C-peptide, higher glycemic variability, longer disease duration, and higher proportion of insulin pump use. Conclusions: The decision rule underscores the benefits of CGM for older adults to reduce hypoglycemia. Diagnostic CGM and laboratory markers may inform decision-making surrounding therapeutic CGM and identify older adults for whom CGM may be a critical intervention to reduce hypoglycemia.
引用
收藏
页码:1079 / 1086
页数:8
相关论文
共 48 条
  • [31] Recovery of hypoglycemic confidence using intermittently scanned continuous glucose monitoring among adults with type 1 diabetes with level 3 hypoglycemia: A prospective, single-center, single-arm study
    Takaike, Hiroko
    Miura, Junnosuke
    Hoshina, Sari
    Takagi, Satoshi
    Takita, Mikako
    Mochizuki, Shota
    Babazono, Tetsuya
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2023, 204
  • [32] Hypoglycaemia measured by continuous glucose monitoring in people with insulin-treated type 2 diabetes and chronic kidney disease: post hoc analysis from the HypoMETRICS study
    Brosen, J. M. B.
    Divilly, P.
    Martine-Edith, G.
    Zaremba, N.
    Ali, N.
    Evans, M.
    McCrimmon, R.
    Heller, S.
    de Galan, B.
    Mader, J.
    Renard, E.
    Vaag, A. A.
    Choudhary, P.
    Bjergaard, U. P.
    DIABETOLOGIA, 2024, 67 : S390 - S391
  • [33] Continuous glucose monitoring versus blood glucose monitoring for risk of severe hypoglycaemia and diabetic ketoacidosis in children, adolescents, and young adults with type 1 diabetes: a population-based study
    Karges, Beate
    Tittel, Sascha R.
    Bey, Alexander
    Freiberg, Clemens
    Klinkert, Christof
    Kordonouri, Olga
    Thiele-Schmitz, Susanne
    Schroeder, Carmen
    Steigleder-Schweiger, Claudia
    Holl, Reinhard W.
    LANCET DIABETES & ENDOCRINOLOGY, 2023, 11 (05): : 314 - 323
  • [34] Impact of continuous glucose monitoring on improving emotional well-being among adults with type 1 diabetes mellitus: a systematic review and meta-analysis
    Klak, Anna
    Manczak, Malgorzata
    Owoc, Jakub
    Olszewski, Robert
    POLISH ARCHIVES OF INTERNAL MEDICINE-POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ, 2021, 131 (09): : 808 - 818
  • [35] Longitudinal association of continuous glucose monitoring-derived metrics with cognitive decline in older adults with type 2 diabetes: A 1-year prospective observational study
    Sugimoto, Taiki
    Tokuda, Haruhiko
    Miura, Hisayuki
    Kawashima, Shuji
    Omura, Takuya
    Ando, Takafumi
    Kuroda, Yujiro
    Matsumoto, Nanae
    Fujita, Kosuke
    Uchida, Kazuaki
    Kishino, Yoshinobu
    Sakurai, Takashi
    DIABETES OBESITY & METABOLISM, 2023, 25 (12): : 3831 - 3836
  • [36] Study of MiniMed 640G Insulin Pump with SmartGuard in Prevention of Low Glucose Events in Adults with Type 1 Diabetes (SMILE): Design of a Hypoglycemia Prevention Trial with Continuous Glucose Monitoring Data as Outcomes
    De Valk, Harold W.
    Lablanche, Sandrine
    Bosi, Emanuele
    Choudhary, Pratik
    Da Silva, Julien
    Castaneda, Javier
    Vorrink, Linda
    De Portu, Simona
    Cohen, Ohad
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 (11) : 758 - 766
  • [37] Deterioration in Glycemic Control on School Days among School-Aged Children with Type 1 Diabetes: A Continuous Glucose Monitoring-Based Study
    Wu, Xiumei
    Zhang, Wen Hao
    Ding, Yu
    Zheng, Xueying
    Weng, Jianping
    Luo, Sihui
    DIABETES, 2022, 71
  • [38] What difference does sleep make? Continuous glucose monitoring metrics during fixed-overnight time versus sleep periods among older adults with type 1 diabetes
    Trawley, Steven
    Kubilay, Erin
    Colman, Peter G.
    Lee, Melissa H.
    O'Neal, David N.
    Sundararajan, Vijaya
    Vogrin, Sara
    Mcauley, Sybil A.
    JOURNAL OF SLEEP RESEARCH, 2024, 33 (04)
  • [39] Real-World Use of Continuous Glucose Monitoring Systems Among Adolescents and Young Adults With Type 1 Diabetes: Reduced Burden, but Little Interest in Data Analysis
    Huhn, Friederike
    Lange, Karin
    Joerdening, Mia
    Ernst, Gundula
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (04): : 943 - 950
  • [40] Reply to Letter by Seibold regarding Monika Reddy, Narvada Jugnee, Sinthuka Anantharaja, and Nick Oliver, Switching from Flash Glucose Monitoring to Continuous Glucose Monitoring on Hypoglycemia in Adults with Type 1 Diabetes at High Hypoglycemia Risk: The Extension Phase of the I HART CGM Study
    Reddy, Monika
    Oliver, Nick
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (02) : 99 - 100