Sub-shot-Noise Circular Dichroism Spectroscopy for the Accelerated Characterization of Molecular Chirality

被引:1
|
作者
Matsuzaki, Korenobu [1 ,2 ]
Tahara, Tahei [1 ,2 ]
机构
[1] RIKEN, Mol Spect Lab, Wako 3510198, Japan
[2] RIKEN, RIKEN Ctr Adv Photon RAP, Ultrafast Spect Res Team, Wako 3510198, Japan
基金
日本学术振兴会;
关键词
entangled photon pairs; shot-noise limit; circulardichroism spectroscopy; molecular chirality; tris(bipyridine)rutheniumion; OPTICAL-ROTATORY DISPERSION;
D O I
10.1021/acsphotonics.4c00182
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Circular dichroism (CD), which detects differential absorption with left- and right-circularly polarized light, is widely used for characterizing molecular chirality. Despite its similarity to absorption spectroscopy, CD spectroscopy typically requires a significantly longer time to acquire a spectrum due to the low intensity of the CD signal. The CD measurements can be accelerated if the noise level in the spectra can be reduced, which facilitates the detection of the weak CD signal. Here we show that such noise suppression is indeed possible using entangled photon pairs as the light source. By taking advantage of the photon number correlation of entangled photon pairs, we suppressed the noise contained in the CD spectra by 30% below the shot-noise limit which is a fundamental limit in conventional CD measurements. As a consequence, sub-shot-noise CD spectroscopy developed in this study is capable of characterizing the molecular chirality twice as fast as conventional CD spectroscopy.
引用
收藏
页码:1376 / 1381
页数:6
相关论文
共 50 条
  • [31] SUB-SHOT-NOISE INTENSITY FLUCTUATIONS IN 4-WAVE MIXING
    ZHANG, WP
    WALLS, DF
    PHYSICAL REVIEW A, 1990, 41 (11): : 6385 - 6392
  • [32] Measurement of Sub-Shot-Noise Spatial Correlations without Background Subtraction
    Brida, Giorgio
    Caspani, Lucia
    Gatti, Alessandra
    Genovese, Marco
    Meda, Alice
    Berchera, Ivano Ruo
    PHYSICAL REVIEW LETTERS, 2009, 102 (21)
  • [33] Sub-shot-noise interferometric timing measurement with a squeezed frequency comb
    Wang, Shaofeng
    Xiang, Xiao
    Treps, Nicolas
    Fabre, Claude
    Liu, Tao
    Zhang, Shougang
    Dong, Ruifang
    PHYSICAL REVIEW A, 2018, 98 (05)
  • [34] Sub-shot-noise interferometric measurements with two-photon states
    Univ of Rochester, Rochester, United States
    Quant Semiclassical Opt J Eur Opt Soc Pt 2, 3 (493-500):
  • [35] Not all pure entangled states are useful for sub-shot-noise interferometry
    Hyllus, Philipp
    Guehne, Otfried
    Smerzi, Augusto
    PHYSICAL REVIEW A, 2010, 82 (01):
  • [36] SUB-SHOT-NOISE MANIPULATION OF LIGHT USING SEMICONDUCTOR EMITTERS AND RECEIVERS
    ROCH, JF
    POIZAT, JP
    GRANGIER, P
    PHYSICAL REVIEW LETTERS, 1993, 71 (13) : 2006 - 2009
  • [37] Sub-shot-noise interferometry from measurements of the one-body density
    Chwedenczuk, J.
    Hyllus, P.
    Piazza, F.
    Smerzi, A.
    NEW JOURNAL OF PHYSICS, 2012, 14
  • [38] SUB-SHOT-NOISE INTENSITY FLUCTUATIONS IN A 4-WAVE-MIXING OSCILLATOR
    ZHANG, WP
    WALLS, DF
    OPTICS COMMUNICATIONS, 1990, 79 (06) : 497 - 508
  • [39] Measurements of liquid surface fluctuations at sub-shot-noise levels with Michelson interferometry
    Mitsui, Takahisa
    Aoki, Kenichiro
    PHYSICAL REVIEW E, 2013, 87 (04):
  • [40] Twin-beam sub-shot-noise raster-scanning microscope
    Sabines-Chesterking, J.
    McMillan, A. R.
    Moreau, P. A.
    Joshi, S. K.
    Knauer, S.
    Johnston, E.
    Rarity, J. G.
    Matthews, J. C. F.
    OPTICS EXPRESS, 2019, 27 (21) : 30810 - 30818