Impact mechanism of rhombus module on plume abatement and water saving of mechanical draft wet cooling tower

被引:4
|
作者
Deng, Weipeng [1 ]
Sun, Fengzhong [1 ]
Chen, Kun [1 ]
Zhang, Xiaoyu [1 ]
机构
[1] Shandong Univ, Sch Energy & Power Engn, Jinan 250061, Peoples R China
关键词
Plume abatement; Water saving; Thermal performance; Rhombus module; Mechanical draft wet cooling tower; THERMAL PERFORMANCE; REDUCE WATER; RETROFIT;
D O I
10.1016/j.applthermaleng.2022.119818
中图分类号
O414.1 [热力学];
学科分类号
摘要
The wet cooling tower usually causes a large amount of water resource waste and generates visible plumes. To solve this problem, a new mechanical draft wet cooling tower with air channels and rhombus modules is proposed. The dry channel and wet channel are staggered in the rhombus module. A hot experiment of the cooling tower is constructed to analyze plume, water saving, and cooling performance. The main experiment variables include the dry bulb temperature, relative humidity, circulating water flow rate, circulating water temperature, crosswind velocity, and crosswind angle. Results show that the cooling tower with the rhombus module does not produce plume under studied conditions. With the increase of the dry bulb temperature, relative humidity, circulating water flow rate, and circulating water temperature, the water saving amount and rate are increased with the maximum value of 0.073 L/min and 24.2 %. As crosswind velocity rises, the water saving amount and rate are increased under the crosswind angle of 0 degrees, and those are decreased under 90 degrees and 180 degrees. The water saving amount and rate can maximum reach 0.060 L/min and 21.2 % under crosswind. Meanwhile, the water temperature drop is decreased by 1.3 degrees C under windless and 1.2 degrees C under crosswind on average.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Water Consumption Comparison Between a Natural Draft Wet Cooling Tower and a Natural Draft Hybrid Cooling TowerAn Annual Simulation for Luoyang Conditions
    Xia, Lin
    Li, Jishun
    Ma, Wei
    Gurgenci, Hal
    Guan, Zhiqiang
    Wang, Pei
    HEAT TRANSFER ENGINEERING, 2017, 38 (11-12) : 1034 - 1043
  • [42] The influence and analysis of natural crosswind on cooling characteristics of the high level water collecting natural draft wet cooling tower
    Ma, Libin
    Ren, Jianxing
    2017 3RD INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION (ESMA2017), VOLS 1-4, 2018, 108
  • [43] VIABILITY STUDY OF RETRIEVING THE EVAPORATED WATER IN A MECHANICAL DRAFT CROSS FLOW COOLING TOWER
    Zimmermann, Rafael
    Mantelli, Marcia B. H.
    Borges, Thomaz P. F.
    Costa, Camilo A. S.
    PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 4: HEAT TRANSFER MEASUREMENT TECHNIQUES, HEAT TRANSFER EQUIPMENT, THERMOELECTRICS, 2010, : 751 - 760
  • [44] Effect mechanism of wind shields on the thermal performance for mechanical draft wet cooling towers
    Chen, Xuehong
    Sun, Fengzhong
    Yang, Shasha
    Xia, Lijiang
    Zhang, Xiaoyu
    APPLIED THERMAL ENGINEERING, 2023, 219
  • [45] Optimization of mechanical draft counter flow wet-cooling tower using artificial bee colony algorithm
    Rao, R. V.
    Patel, V. K.
    ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (07) : 2611 - 2622
  • [46] Thermodynamic Studies of Natural Draft Wet Cooling Tower C of the Neurath Power Plant and Models for the Operational Behavior and the Plume Propagation.
    Baer, Edmund
    Bartels, Helene
    Brandes, Hans Hermann
    Buchholz, Friedhelm
    Caudron, Lionel
    Dewagenaere, Philippe
    Dibelius, Guenther
    Dittrich, Hans
    Ederhof, Alfried
    Egler, Walter
    Ernst, Guenter
    Roegener, Heinz
    Roller, Wilhelm
    Viollet, Pierre Louis
    Wurz, Dieter
    Fortschritt-Berichte der VDI-Zeitschriften, Reihe 4: Bauingenieurwesen, 1979, (7 pt 15):
  • [47] Field test study on water droplet diameter distribution in the rain zone of a natural draft wet cooling tower
    Chen, Xuehong
    Sun, Fengzhong
    Lyu, Dongqiang
    APPLIED THERMAL ENGINEERING, 2019, 162
  • [48] New method to decrease the air recirculation of mechanical draft wet cooling tower group by increasing height of fan duct
    Deng, Weipeng
    Sun, Fengzhong
    Chen, Kun
    Zhang, Xiaoyu
    APPLIED THERMAL ENGINEERING, 2023, 219
  • [49] Research on Gravity Energy Saving Reconstruction Technology of Circulating Cooling Water in Mechanical Ventilation Cooling Tower of a Steel Plant
    Tang, Chuan
    Zhang, Chenghua
    He, Dan
    Zhang, Feng
    Wei, Yu
    Yang, Zhongqing
    Yan, Yunfei
    ENERGIES, 2023, 16 (17)
  • [50] INVESTIGATING THE EFFECTS OF FLUE GAS INJECTION AND HOT WATER DISTRIBUTION AND THEIR INTERACTION ON NATURAL DRAFT WET COOLING TOWER PERFORMANCE
    Eldredge, Tom V.
    Stapleton, John M.
    PROCEEDINGS OF THE ASME POWER CONFERENCE, 2019, 2019,