Tuning Hydrophobicity of Paper Substrates for Effective Colorimetric detection of Glucose and Nucleic acids

被引:9
|
作者
Sudarsan, Sujesh [1 ]
Shetty, Prashil [1 ]
Chinnappan, Raja [2 ]
Mani, Naresh Kumar [1 ]
机构
[1] Manipal Acad Higher Educ, Manipal Inst Technol, Ctr Microfluid Biomarkers Photoceut & Sensors MBi, Dept Biotechnol,Microfluid Sensors & Diagnost MSe, Manipal 576104, Karnataka, India
[2] Alfaisal Univ, Coll Med, Riyadh 11533, Saudi Arabia
关键词
Paper-based analytical device; LAMP amplicon; Serum glucose; Hydrophobicity; Colorimetric enhancement; WETTABILITY;
D O I
10.1007/s00216-023-04921-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study investigated the colorimetric response of standard glucose, serum glucose, and nucleic acid assays on various paper surfaces with different wettability, including hydrophilic, hydrophobic, and nearly superhydrophobic surfaces. Water contact angles (WCA) formed by water droplets on each surface were measured using ImageJ software. The hydrophilic surface showed no contact angle, while the hydrophobic and nearly superhydrophobic surfaces exhibited contact angles of 115.667 degrees and 133.933 degrees, respectively. The colorimetric sensitivity of the standard glucose assay was analyzed on these surfaces, revealing enhanced sensitivity on the nearly superhydrophobic surface due to the high molecular crowding effect owing to its non-wetting behavior and eventually confined reaction product at the sample loading zone. The hydrophobic nature of the surface restricts the spreading and diffusion of the reaction product, leading to a controlled and localized concentration of the assay product leading to moderate colorimetric intensity. On the other hand, the hydrophilic surface showed the least enhancement in colorimetric sensitivity; this is attributed to the high wettability of the hydrophilic surface causing the reaction product to spread extensively, resulting in a larger area of dispersion and consequently a lower colorimetric intensity. The measured limit of detection (LOD) for nucleic acid on nearly superhydrophobic surfaces was found to be 16.15 ng/mu L, which was almost four-fold lower than on hydrophilic surfaces (60.08 ng/mu L). Additionally, the LODs of standard glucose and clinical serum samples were two-fold lower on nearly superhydrophobic surfaces compared to hydrophilic surfaces. Our findings clearly highlight the promising potential of utilizing superhydrophobic surfaces to significantly enhance colorimetric sensitivity in paper-based diagnostic applications. This innovative approach holds promise for advancing point-of-care diagnostics and improving disease detection in resource-limited settings.
引用
收藏
页码:6449 / 6460
页数:12
相关论文
共 50 条
  • [41] Inkjet printed microfluidic paper-based analytical device (μPAD) for glucose colorimetric detection in artificial urine
    Han Zhang
    Ethan Smith
    Wei Zhang
    Anhong Zhou
    Biomedical Microdevices, 2019, 21
  • [42] Portable real-time colorimetric LAMP-device for rapid quantitative detection of nucleic acids in crude samples
    G. Papadakis
    A. K. Pantazis
    N. Fikas
    S. Chatziioannidou
    V. Tsiakalou
    K. Michaelidou
    V. Pogka
    M. Megariti
    M. Vardaki
    K. Giarentis
    J. Heaney
    E. Nastouli
    T. Karamitros
    A. Mentis
    A. Zafiropoulos
    G. Sourvinos
    S. Agelaki
    E. Gizeli
    Scientific Reports, 12
  • [43] Rapid and colorimetric detection of nucleic acids based on entropy-driven circuit and DNAzyme-mediated autocatalytic reactions
    Shi, Hongli
    Dai, Jianyuan
    Wang, Fang
    Xia, Yushun
    Xiao, Dan
    Zhou, Cuisong
    ANALYTICAL METHODS, 2020, 12 (21) : 2779 - 2784
  • [44] Portable real-time colorimetric LAMP-device for rapid quantitative detection of nucleic acids in crude samples
    Papadakis, G.
    Pantazis, A. K.
    Fikas, N.
    Chatziioannidou, S.
    Tsiakalou, V
    Michaelidou, K.
    Pogka, V
    Megariti, M.
    Vardaki, M.
    Giarentis, K.
    Heaney, J.
    Nastouli, E.
    Karamitros, T.
    Mentis, A.
    Zafiropoulos, A.
    Sourvinos, G.
    Agelaki, S.
    Gizeli, E.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [45] Carbon nanotube-based labels for highly sensitive colorimetric and aggregation-based visual detection of nucleic acids
    Lee, Ai Cheng
    Ye, Jian-Shan
    Tan, Swee Ngin
    Poenar, Daniel P.
    Sheu, Fwu-Shan
    Heng, Chew Kiat
    Lim, Tit Meng
    NANOTECHNOLOGY, 2007, 18 (45)
  • [46] Inkjet printed microfluidic paper-based analytical device (PAD) for glucose colorimetric detection in artificial urine
    Zhang, Han
    Smith, Ethan
    Zhang, Wei
    Zhou, Anhong
    BIOMEDICAL MICRODEVICES, 2019, 21 (03)
  • [47] Nanohybrids consisting of magnetic nanoparticles and gold nanoclusters as effective peroxidase mimics and their application for colorimetric detection of glucose
    Cho, Seongyeon
    Shin, Ho Yun
    Kim, Moon Il
    BIOINTERPHASES, 2017, 12 (01)
  • [48] Gold Nanorods as Colorful Chromogenic Substrates for Semiquantitative Detection of Nucleic Acids, Proteins, and Small Molecules with the Naked Eye
    Ma, Xiaoming
    Chen, Zhitao
    Kannan, Palanisamy
    Lin, Zhenyu
    Qiu, Bin
    Guo, Longhua
    ANALYTICAL CHEMISTRY, 2016, 88 (06) : 3227 - 3234
  • [49] Fast and Effective Turn-on Paper-based Phosphorescence Biosensor for Detection of Glucose in Serum
    Chen, Yi-An
    Tsai, Fu-Ju
    Zeng, Yu-Ting
    Wang, Jing-Chang
    Hong, Chia Ping
    Huang, Pin-Hsuan
    Chuang, Hsiang-Ling
    Lin, Shih-Yao
    Chan, Chu-Ting
    Ko, Yu-Chien
    Chou, Yi-Chieh
    Lin, Tien-Li
    Lee, Gene-Hsiang
    Ho, Mei-Lin
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2016, 63 (05) : 424 - 431
  • [50] Cyclohexanyl peptide nucleic acids (chPNAs) for preferential RNA binding:: Effective tuning of dihedral angle β in PNAs for DNA/RNA discrimination
    Govindaraju, T
    Madhuri, V
    Kumar, VA
    Ganesh, KN