Tuning Hydrophobicity of Paper Substrates for Effective Colorimetric detection of Glucose and Nucleic acids

被引:9
|
作者
Sudarsan, Sujesh [1 ]
Shetty, Prashil [1 ]
Chinnappan, Raja [2 ]
Mani, Naresh Kumar [1 ]
机构
[1] Manipal Acad Higher Educ, Manipal Inst Technol, Ctr Microfluid Biomarkers Photoceut & Sensors MBi, Dept Biotechnol,Microfluid Sensors & Diagnost MSe, Manipal 576104, Karnataka, India
[2] Alfaisal Univ, Coll Med, Riyadh 11533, Saudi Arabia
关键词
Paper-based analytical device; LAMP amplicon; Serum glucose; Hydrophobicity; Colorimetric enhancement; WETTABILITY;
D O I
10.1007/s00216-023-04921-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study investigated the colorimetric response of standard glucose, serum glucose, and nucleic acid assays on various paper surfaces with different wettability, including hydrophilic, hydrophobic, and nearly superhydrophobic surfaces. Water contact angles (WCA) formed by water droplets on each surface were measured using ImageJ software. The hydrophilic surface showed no contact angle, while the hydrophobic and nearly superhydrophobic surfaces exhibited contact angles of 115.667 degrees and 133.933 degrees, respectively. The colorimetric sensitivity of the standard glucose assay was analyzed on these surfaces, revealing enhanced sensitivity on the nearly superhydrophobic surface due to the high molecular crowding effect owing to its non-wetting behavior and eventually confined reaction product at the sample loading zone. The hydrophobic nature of the surface restricts the spreading and diffusion of the reaction product, leading to a controlled and localized concentration of the assay product leading to moderate colorimetric intensity. On the other hand, the hydrophilic surface showed the least enhancement in colorimetric sensitivity; this is attributed to the high wettability of the hydrophilic surface causing the reaction product to spread extensively, resulting in a larger area of dispersion and consequently a lower colorimetric intensity. The measured limit of detection (LOD) for nucleic acid on nearly superhydrophobic surfaces was found to be 16.15 ng/mu L, which was almost four-fold lower than on hydrophilic surfaces (60.08 ng/mu L). Additionally, the LODs of standard glucose and clinical serum samples were two-fold lower on nearly superhydrophobic surfaces compared to hydrophilic surfaces. Our findings clearly highlight the promising potential of utilizing superhydrophobic surfaces to significantly enhance colorimetric sensitivity in paper-based diagnostic applications. This innovative approach holds promise for advancing point-of-care diagnostics and improving disease detection in resource-limited settings.
引用
收藏
页码:6449 / 6460
页数:12
相关论文
共 50 条
  • [1] Tuning Hydrophobicity of Paper Substrates for Effective Colorimetric detection of Glucose and Nucleic acids
    Sujesh Sudarsan
    Prashil Shetty
    Raja Chinnappan
    Naresh Kumar Mani
    Analytical and Bioanalytical Chemistry, 2023, 415 : 6449 - 6460
  • [2] A NOVEL COLORIMETRIC DETECTION SYSTEM FOR NUCLEIC-ACIDS
    VERMEULEN, NMJ
    GAMPER, H
    VANNESS, J
    FASEB JOURNAL, 1991, 5 (06): : A1625 - A1625
  • [3] Highly effective colorimetric and visual detection of nucleic acids using an asymmetrically split peroxidase DNAzyme
    Deng, Minggang
    Zhang, Dan
    Zhou, Yangyang
    Zhou, Xiang
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (39) : 13095 - 13102
  • [4] Dicationic styryl dyes for colorimetric and fluorescent detection of nucleic acids
    Supabowornsathit, Kotchakorn
    Faikhruea, Kriangsak
    Ditmangklo, Boonsong
    Jaroenchuensiri, Theeranuch
    Wongsuwan, Sutthida
    Junpra-ob, Sirikarn
    Choopara, Ilada
    Palaga, Tanapat
    Aonbangkhen, Chanat
    Somboonna, Naraporn
    Taechalertpaisarn, Jaru
    Vilaivan, Tirayut
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [5] Intelligent DNA machine for the ultrasensitive colorimetric detection of nucleic acids
    Xu, Jianguo
    Qian, Jun
    Li, Hongling
    Wu, Zai-Sheng
    Shen, Weiyu
    Jia, Lee
    BIOSENSORS & BIOELECTRONICS, 2016, 75 : 41 - 47
  • [6] Dicationic styryl dyes for colorimetric and fluorescent detection of nucleic acids
    Kotchakorn Supabowornsathit
    Kriangsak Faikhruea
    Boonsong Ditmangklo
    Theeranuch Jaroenchuensiri
    Sutthida Wongsuwan
    Sirikarn Junpra-ob
    Ilada Choopara
    Tanapat Palaga
    Chanat Aonbangkhen
    Naraporn Somboonna
    Jaru Taechalertpaisarn
    Tirayut Vilaivan
    Scientific Reports, 12
  • [7] Paper integrated microfluidic contact lens for colorimetric glucose detection
    Isgor, Pelin Kubra
    Abbasiasl, Taher
    Das, Ritu
    Istif, Emin
    Yener, Umut Can
    Beker, Levent
    SENSORS & DIAGNOSTICS, 2024, 3 (10): : 1743 - 1748
  • [8] Universal colorimetric detection of nucleic acids based on polydiacetylene (PDA) liposomes
    Jung, Yun Kyung
    Kim, Tae Won
    Kim, Jumi
    Kim, Jong-Man
    Park, Hyun Gyu
    ADVANCED FUNCTIONAL MATERIALS, 2008, 18 (05) : 701 - 708
  • [9] Flow-through colorimetric assay for detection of nucleic acids in plasma
    Ammanath, Gopal
    Yeasmi, Sanjida
    Srinivasulu, Yuvasri
    Vats, Mukti
    Cheema, Jamal Ahmed
    Nabilah, Fairuz
    Srivastava, Rohit
    Yildiz, Umit Hakan
    Alagappan, Palaniappan
    Liedberg, Bo
    ANALYTICA CHIMICA ACTA, 2019, 1066 : 102 - 111
  • [10] A nuclease protection ELISA assay for colorimetric and electrochemical detection of nucleic acids
    Filer, Jessica E.
    Channon, Robert B.
    Henry, Charles S.
    Geiss, Brian J.
    ANALYTICAL METHODS, 2019, 11 (08) : 1027 - 1034