Electrochemical determination of eugenol using a poly-γ-aminobutyric acid modified glassy carbon electrode

被引:2
|
作者
Yin, Mingjing [1 ]
Liu, Shanshan [1 ]
Ma, Xinying [1 ]
Meng, Xiangyan [1 ]
Chao, Mingyong [1 ]
机构
[1] Heze Univ, Coll Chem & Chem Engn, Heze 274015, Peoples R China
来源
关键词
Eugenol; gamma-aminobutyric acid; Electrochemical sensor; Cyclic voltammetry; ASCORBIC-ACID; URIC-ACID; MECHANISM; DOPAMINE; OXIDATION; EXTRACT;
D O I
10.1016/j.ijoes.2023.100380
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Eugenol, an active substance widely used in the medical, food, and cosmetic industries, has garnered increasing attention due to its potential adverse effects on human health resulting from excessive use. In this study, a sensitive sensor for the determination of eugenol was developed by electropolymerizing gamma-aminobutyric acid (gABA) onto the surface of a glassy carbon electrode (GCE). Experiments showed that the poly gamma-aminobutyric acid (pgABA) membrane exhibited excellent electrocatalytic activity for the oxidation of eugenol, and its oxidation peak current was greatly increased. Under optimized conditions, the oxidation peak current of eugenol was linearly proportional to its concentration in a range of 0.6-100 mu mol/L, with a correlation coefficient of 0.9985 and a detection limit of 0.2 mu mol/L. The sensor's ability to detect eugenol in various authentic samples, with recovery rates ranging from 98.0 % to 101.3 %, attests to its great potential for practical application.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Poly-(Alizarin Red S)-Modified Glassy Carbon Electrode for Simultaneous Electrochemical Determination of Levodopa, Homovanillic Acid and Ascorbic Acid
    Hatefi-Mehrjardi, Abdolhamid
    Ghaemi, Nasrin
    Karimi, Mohammad Ali
    Ghasemi, Masoumeh
    Islami-Ramchahi, Somaieh
    ELECTROANALYSIS, 2014, 26 (11) : 2491 - 2500
  • [2] Electrochemical determination of dopamine using a poly(2-picolinic acid) modified glassy carbon electrode
    Zhao, H
    Zhang, YZ
    Yuan, ZB
    ANALYST, 2001, 126 (03) : 358 - 360
  • [3] Electrochemical Determination of Bisphenol A Based on Poly(Chromotropic Acid) Modified Glassy Carbon Electrode
    Filik, Hayati
    Avan, Asiye Aslihan
    CURRENT ANALYTICAL CHEMISTRY, 2017, 13 (06) : 464 - 473
  • [4] Simultaneous determination of ascorbic acid, dopamine and uric acid using poly(4-aminobutyric acid) modified glassy carbon electrode
    Zheng, Xinyu
    Zhou, Xuechou
    Ji, Xiaoyan
    Lin, Ruiyu
    Lin, Wenxiong
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 : 359 - 365
  • [5] Electrochemical Determination of Levofloxacin Using Poly(Pyrogallol Red) Modified Glassy Carbon Electrode
    Kocak, Cagri Ceylan
    Aslisen, Burak
    Karabiberoglu, Sukriye
    Ozdokur, Kemal Volkan
    Aslan, Avni
    Kocak, Suleyman
    CHEMISTRYSELECT, 2022, 7 (41):
  • [6] Electrochemical determination of ascorbic acid using Cu sulfide modified glassy carbon electrode
    Pei L.Z.
    Lin N.
    Wei T.
    Liu H.D.
    Cai Z.Y.
    Surface Engineering and Applied Electrochemistry, 2016, 52 (6) : 565 - 571
  • [7] Electrochemical Determination of Amoxicillin on a Poly(Acridine Orange) Modified Glassy Carbon Electrode
    Agin, Fatma
    ANALYTICAL LETTERS, 2016, 49 (09) : 1366 - 1378
  • [8] Electrochemical determination of dopamine in the presence of ascorbic acid using a poly( 3-acetylthiophene) modified glassy carbon electrode
    Aslanoglu, Mehmet
    Abbasoglu, Sultan
    Karabulut, Serpil
    Kutluay, Aysegul
    ACTA CHIMICA SLOVENICA, 2007, 54 (04) : 834 - 839
  • [9] Sensitive electrochemical determination of Sudan II in food samples using a poly(aminosulfonic acid) modified glassy carbon electrode
    Xinying Ma
    Mingyong Chao
    Russian Journal of Electrochemistry, 2013, 49 : 1057 - 1064
  • [10] Sensitive electrochemical determination of Sudan II in food samples using a poly(aminosulfonic acid) modified glassy carbon electrode
    Ma, Xinying
    Chao, Mingyong
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2013, 49 (11) : 1057 - 1064