Predictors of ventricular tachyarrhythmia in patients with implantable cardioverter-defibrillator and non-ischemic systolic heart failure

被引:0
|
作者
Jedrzejczyk-Patej, Ewa [1 ,6 ]
Mazurek, Michal [1 ]
Lazar, Monika [1 ]
Pruszkowska-Skrzep, Patrycja [1 ]
Sokal, Adam [1 ,2 ,3 ]
Kowalczyk, Jacek [4 ,5 ]
Kowalski, Oskar [1 ,2 ,3 ]
Kalarus, Zbigniew [4 ,5 ]
Lenarczyk, Radoslaw [4 ,5 ]
机构
[1] Silesian Ctr Heart Dis, Dept Cardiol Congenital Heart Dis & Electrotherapy, Zabrze, Poland
[2] Fac Hlth Sci, Dept Human Nutr, Dept Dietet, Bytom, Poland
[3] Med Univ Silesia, Katowice, Poland
[4] Med Univ Silesia, Div Med Sci Zabrze, Katowice, Poland
[5] Silesian Ctr Heart Dis, Dept Cardiol, Zabrze, Poland
[6] Silesian Ctr Heart Dis, Dept Cardiol Congenital Heart Dis & Electrotherapy, Sklodowskiej Curie 9, PL-41800 Zabrze, Poland
关键词
appropriate therapy; heart failure; implantable cardioverter-defibrillator; predictors; ventricular arrhythmia; ATRIAL-FIBRILLATION; PRIMARY PREVENTION; CARDIOMYOPATHY; THERAPY; BENEFIT; DEATH; RISK;
D O I
10.33963/v.kp.97000
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background:The benefit derived from implantable cardioverter-defibrillators (ICD) in subjects with non-ischemic systolic HF (NICM) is less well-established. Aim: The study aimed to determine the incidence, predictors, and prognostic impact of ventricular arrhythmias in patients with ICD and NICM. Methods: The study sample included 377 consecutive patients with ICD or cardiac resynchronization cardioverter-defibrillators (CRT-D, 74% of patients) and NICM implanted and monitored remotely in a university hospital. Results: During the median (interquartile range [IQR]) follow-up of 1645 (960-2675) days, sus-tained ventricular arrhythmia occurred in 92 patients (24.4%). Of those, ventricular fibrillation (VF), ventricular tachycardia (VT), and both VT and VF occurred in 10 (10.9%), 72 (78.3%), and 10 (10.9%) patients, respectively. Patients with vs. those without ventricular arrhythmia differed concerning sex, left ventricular end-diastolic diameter (LVEDD), left ventricular end-systolic diameter (LVESD), left ventricular ejection fraction (LVEF), post-inflammatory etiology, atrial fibrillation/flutter occur-rence, and supraventricular arrhythmia (SVT) other than AF/AFL during follow-up. In multivariable Cox regression, LVEDD (hazard ratio [HR], 1.05; 95% confidence interval [CI], 1.003-1.09; P = 0.03), AF/AFL (HR, 1.86; 95% CI, 1.21-2.85; P = 0.004), and SVT (HR, 1.77; 95% CI, 1.10-2.87; P = 0.02) were independent predictors of sustained VT, while AF/AFL (HR, 1.65; 95% CI, 1.07-2.56; P = 0.02) was independent predictor of VF. All-cause mortality in patients with VT/VF was significantly higher than in subjects without sustained ventricular arrhythmias (35.9% vs. 22.4%; P = 0.01). Conclusions: Ventricular arrhythmia occurred in every fourth patient with NICM and ICD during 4.5 years of observation and was associated with significantly worse prognosis than in subjects free of VT/VF. Higher LVEDD, atrial fibrillation/atrial flutter, and supraventricular tachycardia flag patients at risk of ventricular arrhythmia.
引用
收藏
页码:998 / 1005
页数:8
相关论文
共 50 条
  • [21] Duration of heart failure and effect of defibrillator implantation in patients with non-ischemic systolic heart failure
    Elming, M. B.
    Thoegersen, A. M.
    Videbaek, L.
    Bruun, N. E.
    Eiskjaer, H.
    Haarbo, J.
    Egstrup, K.
    Gustafsson, F.
    Svendsen, J. H.
    Hoefsten, D. E.
    Pehrson, S.
    Nielsen, J. C.
    Koeber, L. V.
    Thune, J. J.
    EUROPEAN HEART JOURNAL, 2019, 40 : 2753 - 2753
  • [22] The effect of implantable cardioverter-defibrillator in patients with diabetes and non-ischaemic systolic heart failure: Author's reply
    Rorth, Rasmus
    EUROPACE, 2020, 22 (02): : 331 - 332
  • [23] IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR THERAPY IN PATIENTS AGED OVER 75 YEARS WITH ISCHEMIC SYSTOLIC HEART FAILURE AS COMPARED WITH MEDICAL THERAPY
    Cortes, Marcelino
    Martinez Milla, Juan
    Ana, Devesa
    Rivero Monteagudo, Ana Lucia
    Taibo Urquia, Mikel
    Lopez-Castillo, Marta
    Martin-Mariscal, Maria
    Briongos-Figuero, Sem
    Franco Pelaez, Juan Antonio
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 697 - 697
  • [24] Implantable cardioverter-defibrillator treatment and resynchronisation in heart failure
    Linde, C
    HEART, 2004, 90 (02) : 231 - 234
  • [25] Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure
    Bardy, GH
    Lee, KL
    Mark, DB
    Poole, JE
    Packer, DL
    Boineau, R
    Domanski, M
    Troutman, C
    Anderson, J
    Johnson, G
    McNulty, SE
    Clapp-Channing, N
    Davidson-Ray, LD
    Fraulo, ES
    Fishbein, DP
    Luceri, RM
    Ip, JH
    NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03): : 225 - 237
  • [26] Prognostic value of a restrictive mitral filling pattern in patients with systolic heart failure and an implantable cardioverter-defibrillator
    Bruch, C
    Gotzmann, M
    Sindermann, E
    Breithardt, G
    Wichter, T
    Böcker, D
    Gradaus, R
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (05): : 676 - 680
  • [27] ASSOCIATION OF DEVICE DETECTED ATRIAL AND VENTRICULAR TACHYARRHYTHMIA WITH ADVERSE EVENTS IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    Abbas, Hassan
    Younis, Arwa
    Goldenberg, Ilan
    McNitt, Scott
    Aktas, Mehmet K.
    Ojo, Amole
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 454 - 454
  • [28] Incidence of and predictors for appropriate implantable cardioverter-defibrillator therapy in patients with a secondary preventive implantable cardioverter-defibrillator indication
    Schaer, Beat
    Kuehne, Michael
    Reichlin, Tobias
    Osswald, Stefan
    Sticherling, Christian
    EUROPACE, 2016, 18 (02): : 227 - 231
  • [29] Association of device detected atrial and ventricular tachyarrhythmia with adverse events in patients with an implantable cardioverter-defibrillator
    Abbas, Hassan
    Younis, Arwa
    Goldenberg, Ilan
    McNitt, Scott
    Aktas, Mehmet K.
    Tabaja, Chadi
    Ojo, Amole
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (06) : 1203 - 1211
  • [30] Exercise Training and Implantable Cardioverter-Defibrillator Shocks in Patients With Heart Failure
    Piccini, Jonathan P.
    Hellkamp, Anne S.
    Whellan, David J.
    Ellis, Stephen J.
    Keteyian, Steven J.
    Kraus, William E.
    Hernandez, Adrian F.
    Daubert, James P.
    Piña, Ileana L.
    O'Connor, Christopher M.
    JACC-HEART FAILURE, 2013, 1 (02) : 142 - 148