Full-Scale Fire Resistance Testing and Two-Scale Simulations of Sandwich Panels with Connections

被引:6
|
作者
Xu, Qingfeng [1 ]
Hofmeyer, Herm [1 ]
Maljaars, Johan [1 ,2 ]
van Herpen, Ruud A. P. [1 ,3 ]
机构
[1] Eindhoven Univ Technol, Eindhoven, Netherlands
[2] TNO, The Hague, Netherlands
[3] Peutz, Eindhoven, Netherlands
关键词
Sandwich panel; Connection; Fire resistance test; Fire dynamics simulation; Finite element model; Two-scale model; Heat transfer analysis; Structural response analysis; THERMOMECHANICAL FE ANALYSES; THIN SHEET STEELS; SCREWED CONNECTIONS; ELEVATED-TEMPERATURES; CFD FIRE;
D O I
10.1007/s10694-023-01463-y
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
To understand sandwich panel behaviour under fire, expensive full-scale tests, or potentially more efficient fire-structure simulations can be carried out. However, these simulations have only been demonstrated to work for specific applications, either on the global scale (a fire on a simple panel) or on the small scale (a temperature load on a single screw connection), often loaded by a standard fire curve. In this paper, the quality of simulations for combined situations is investigated, i.e. a furnace fire on a set of panels including details and connections. First two existing tests are introduced, a sandwich panel facade test and a studs bolt test, followed by the presentation of their basic fire-structure simulations. In general, the heat transfer analyses agree well with the tests, whereas the structural response analyses need investigation: For the first test, out-of-plane deflections are overestimated at the beginning of the test. A parameter study indicates that this is most likely due to adhesive decomposition, resulting in face delamination and related instabilities. For the second test, the basic simulation does not show any failure, whereas the test failed by vertical bearing. However, with a two-scale model the ultimate load is estimated, and increasing vertical displacements and the onset of vertical bearing are predicted. It is concluded that future tests should include more simulation-relevant measurements. Also, global-scale models need to include features specific to the structure to be simulated, only known after tests and basic simulations, and connections may be decisive for global-scale behaviour, which can be incorporated by a two-scale model. Finally, the tests exhibited complex behaviour across different scales, and modifications and improvements of the simulations increased their fidelity. Therefore fire-structure simulations should always be verified with tests and compared with basic simulations, and modifications in the simulation models should be anticipated.
引用
收藏
页码:2461 / 2488
页数:28
相关论文
共 50 条
  • [1] Full-scale testing of fuselage panels
    Bakuckas, JG
    Bigelow, CA
    Tan, PW
    Awerbuch, J
    Lau, AC
    Tan, TM
    IEEE SYSTEMS READINESS TECHNOLOGY CONFERENCE: 2001 IEEE AUTOTESTCON PROCEEDINGS, 2001, : 827 - 846
  • [2] Full scale testing of precast concrete sandwich panels
    Salmon, DC
    Einea, A
    Tadros, MK
    Culp, TD
    ACI STRUCTURAL JOURNAL, 1997, 94 (04) : 354 - 362
  • [3] Full-scale fire testing of battery electric vehicles
    Kang, Sungwook
    Kwon, Minjae
    Choi, Joung Yoon
    Choi, Sengkwan
    APPLIED ENERGY, 2023, 332
  • [4] Precast TRC sandwich panels for energy retrofitting of existing residential buildings: full-scale testing and modelling
    Colombo, Isabella G.
    Colombo, Matteo
    di Prisco, Marco
    MATERIALS AND STRUCTURES, 2019, 52 (05)
  • [5] Precast TRC sandwich panels for energy retrofitting of existing residential buildings: full-scale testing and modelling
    Isabella G. Colombo
    Matteo Colombo
    Marco di Prisco
    Materials and Structures, 2019, 52
  • [6] FULL-SCALE FIRE RESISTANCE TESTING OF CONCRETE BEAMS REINFORCED WITH VARIOUS FRP REINFORCEMENT
    Protchenko, K.
    Urbanski, M.
    ARCHIVES OF CIVIL ENGINEERING, 2020, 66 (04) : 119 - 136
  • [7] Full-scale testing of a damaged reinforced concrete frame in fire
    Sharma, Umesh Kumar
    Usmani, Asif
    Bhargava, Pradeep
    Torero, Jose
    Singh, Bhupinder
    Gillie, Martin
    Singh, Yogendra
    Pankaj, Pankaj
    Kumar, Virendra
    May, Ian
    Kamath, Praveen
    Zhang, Jian
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2012, 165 (07) : 335 - 346
  • [8] Comparative full-scale fire performance testing of ETICS systems
    Bjegovic, Dubravka
    Pecur, Ivana Banjad
    Milovanovic, Bojan
    Rukavina, Marija Jelcic
    Bagaric, Marina
    GRADEVINAR, 2016, 68 (05): : 357 - 369
  • [9] Full scale testing of precast concrete sandwich panels. Discussion
    LaBelle, J
    ACI STRUCTURAL JOURNAL, 1998, 95 (06) : 768 - 768
  • [10] Two-scale micropolar plate model for web-core sandwich panels
    Karttunen, Anssi T.
    Reddy, J. N.
    Romanoff, Jani
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2019, 170 : 82 - 94