Full-scale fire testing of battery electric vehicles

被引:36
|
作者
Kang, Sungwook [1 ]
Kwon, Minjae [1 ,2 ]
Choi, Joung Yoon [1 ]
Choi, Sengkwan [3 ,4 ]
机构
[1] Fire Testing & Res Ctr, Fire & Disaster Management Div, Korea Conform Labs, Seoul, South Korea
[2] Dongkuk Univ, Dept Chem, Adv Funct Nanohybrid Mat Lab, Seoul, South Korea
[3] Ulster Univ, Sch Built Environm, Belfast, North Ireland
[4] Ulster Univ, Belfast Sch Architecture & Built Environm, 2-24 York St, Belfast BT15 1AF, North Ireland
关键词
Battery electric vehicle; Thermal runaway; Lithium -ion battery; Full-scale fire testing; Thermal behaviour; BEHAVIOR;
D O I
10.1016/j.apenergy.2022.120497
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The market share of electric vehicles, powered by lithium-ion batteries (LIB), has been expanding worldwide with the global momentum towards green technology and improving the driving range on one full-charge. Studies are, however, still required on the fire safety of the latest but unmatured technology due to a distinc-tive phenomenon called thermal runaway. In this study, a series of full-scale fire experiments were conducted, focusing on the understanding of thermal behaviours of battery electric vehicle (BEV) fires. To provide up-to-date information on BEV fires, the latest BEV model with a high electric-energy capacity (64 kWh) was selected. For comparative analysis purposes, a LIB pack and a BEV body were tested individually after being physically dis-assembled. An internal combustion engine vehicle and a hydrogen fuel cell electric vehicle were also tested. During testing, the combustion of the BEV fires continued for approximately 70 min, resulting in critical mea-sures of burning being determined; peak heat release rate (pHRR), total heat released (THR), fire growth parameter, and the average effective heat of combustion were measured to be 6.51-7.25 MW, 8.45-9.03 GJ, 0.0085-0.020, and 29.8-30.5 MJ/kg, respectively. It was also observed that the pHRR and THR were governed by the combustion characteristics of typical combustible materials in the passenger cabin, rather than by that of particular contents in the LIB pack with thermal runaway. Instead, a jet fire intensively discharging from the LIB pack led to a rapid flame spreading to adjacent combustible components of the BEV, thereby accelerating the fire growth. The findings could contribute to the activities of the first responders to BEV fire accidents, fire safety engineers, and structural member designers. This study also makes public the measured thermal quantities for further studies on the fire safety of existing or designing car-parking related structures.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Full-Scale Fire Testing to Assess the Risk of Battery Electric Vehicle Fires in Underground Car Parks
    Kang, Sungwook
    Kwon, Minjae
    Choi, Joung Yoon
    Choi, Sengkwan
    FIRE TECHNOLOGY, 2025,
  • [2] Full-scale Fire Tests of Electric Drive Vehicle Batteries
    Blum, Andrew
    Long, Richard Thomas
    SAE INTERNATIONAL JOURNAL OF PASSENGER CARS-MECHANICAL SYSTEMS, 2015, 8 (02): : 565 - 572
  • [3] Full-scale testing of stability curves for vehicles in flood waters
    Smith, Grantley P.
    Modra, Benjamin D.
    Felder, Stefan
    JOURNAL OF FLOOD RISK MANAGEMENT, 2019, 12
  • [4] Full-scale testing of a damaged reinforced concrete frame in fire
    Sharma, Umesh Kumar
    Usmani, Asif
    Bhargava, Pradeep
    Torero, Jose
    Singh, Bhupinder
    Gillie, Martin
    Singh, Yogendra
    Pankaj, Pankaj
    Kumar, Virendra
    May, Ian
    Kamath, Praveen
    Zhang, Jian
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2012, 165 (07) : 335 - 346
  • [5] Comparative full-scale fire performance testing of ETICS systems
    Bjegovic, Dubravka
    Pecur, Ivana Banjad
    Milovanovic, Bojan
    Rukavina, Marija Jelcic
    Bagaric, Marina
    GRADEVINAR, 2016, 68 (05): : 357 - 369
  • [6] Full-scale experimental study on suppressing lithium-ion battery pack fires from electric vehicles
    Cui, Yan
    Liu, Jianghong
    Han, Xin
    Sun, Shaohua
    Cong, Beihua
    FIRE SAFETY JOURNAL, 2022, 129
  • [7] Field and full-scale laboratory testing of prototype wildland fire shelters
    Roise, Joseph
    Williams, John
    Barker, Roger
    Morton-Aslanis, John
    INTERNATIONAL JOURNAL OF WILDLAND FIRE, 2022, 31 (05) : 518 - 528
  • [8] FULL-SCALE FIRE TESTING OF UPHOLSTERED FURNITURE AND THE USE OF TEST DATA
    SUNDSTROM, B
    CELLULAR POLYMERS, 1987, 6 (05) : 28 - 38
  • [9] Full Scale Fire Tests with Batterie Electric Vehicles in Road Tunnels
    Sturm, Peter
    Fössleitner, Patrik
    Fruhwirt, Daniel
    Schirmer, Andrea
    Reinwald, Bernhard
    Kühbacher, Manuel
    Wenighofer, Robert
    Heindl, Simon
    Nöst, Thomas
    Leonhardt, Philip
    Hödl, Alexander
    Krausbar, Stefan
    BHM Berg- und Huttenmannische Monatshefte, 2020, 165 (12): : 651 - 657
  • [10] FULL-SCALE FIRE TEST PROGRAM
    ALPERT, RL
    FIRELINE, 1978, 5 (01): : 7 - 7