The longitudinal energy spread of ion beams extracted from an electron cyclotron resonance ion source

被引:2
|
作者
Angot, J. [1 ]
Tarvainen, O. [2 ]
Chauveau, P. [3 ]
Kosonen, S. T. [4 ]
Kalvas, T. [4 ]
Thuillier, T. [1 ]
Migliore, M. [1 ]
Maunoury, L. [3 ]
机构
[1] Univ Grenoble Alpes, CNRS, Grenoble INP, LPSC IN2P3, F-38000 Grenoble, France
[2] Rutherford Appleton Lab, STFC ISIS Pulsed Spallat Neutron & Muon Facil, Harwell OX11 0QX, England
[3] Grand Accelerateur Natl Ions Lourds GANIL, F-14076 Caen 5, France
[4] Univ Jyvdskyld, Accelerator Lab, Dept Phys, Survontie 9, FIZ-40500 Jyvdskyld, Finland
关键词
Ion sources (positive ions; negative ions; electron cyclotron resonance (ECR); electron beam (EBIS)); Instrumentation for particle accelerators and storage rings-low energy (linear accelerators; cyclotrons; electrostatic accelerators);
D O I
10.1088/1748-0221/18/04/P04018
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present a study of factors affecting the energy spread of ion beams extracted from a Charge Breeder Electron Cyclotron Resonance Ion Source (CB-ECRIS). The comprehensive simulations, supported by experiments with a Retarding Field Analyser (RFA), reveal that the longitudinal and transverse energy spread of the extracted beams are strongly affected by the electrostatic focusing effects, namely the extraction geometry and plasma beam boundary, to the extent that the electrostatic effects dominate over the magnetic field induced rotation of the beam or the effect of plasma potential and ion temperature. The dominance of the electrostatic focusing effect over the magnetic field induced rotation complicates parametric studies of the transverse emittance as a function of the magnetic field strength, and comparison of emittance values obtained with different ion sources having different extraction designs. Our results demonstrate that the full ion beam energy spread, relevant for the downstream accelerator, can be measured with the RFA only when all ions are collected. On the contrary, studying the effect of plasma properties (plasma potential and ion temperature) on the longitudinal energy spread requires heavy collimation of the beam accepting only ions near the symmetry axis of the beam for which the electrostatic and magnetic effects are suppressed. As the extraction system of the CB-ECRIS is similar to a conventional ECRIS, the conclusions of the study can be generalised to apply for all high charge state ECR ion sources. Finally, we present the results of systematic plasma potential measurements of the Phoenix-type CB-ECRIS at LPSC, varying the source potential, the microwave power and the axial magnetic field srength. It was observed that the plasma potential increases with the extraction magnetic field and the microwave power.
引用
收藏
页数:42
相关论文
共 50 条
  • [41] Ion concentration ratio measurements of ion beams generated by a commercial microwave electron cyclotron resonance plasma source
    Abe, Shota
    Koel, Bruce E.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (11):
  • [42] Electron Cyclotron Resonance Ion Sources for Highly-Charged Ion Beams
    Koivisto, H.
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2009, 1099 : 25 - 30
  • [43] Study of the extracted beam and the radial magnetic field of electron cyclotron resonance ion source at HIMAC
    Kitagawa, A
    Muramatsu, M
    Sasaki, M
    Yamada, S
    Biri, S
    Jincho, K
    Okada, T
    Sakuma, T
    Takasugi, W
    Yamamoto, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (02): : 604 - 606
  • [44] Effect of Electron-Cyclotron Resonance Conditions in a Microwave Discharge of an Ion Source on the Extracted Current
    Stepanov, D. S.
    Shkol'nikov, E. Ya.
    HIGH TEMPERATURE, 2022, 60 (02) : 159 - 164
  • [45] Effect of magnetic-field configuration on the beam intensity from electron cyclotron resonance ion source and RIKEN superconducting electron cyclotron resonance ion source
    Nakagawa, T.
    Higurashi, Y.
    Kidera, M.
    Aihara, T.
    Kase, M.
    Goto, A.
    Yano, Y.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (03):
  • [46] Effect of Electron-Cyclotron Resonance Conditions in a Microwave Discharge of an Ion Source on the Extracted Current
    D. S. Stepanov
    E. Ya. Shkol’nikov
    High Temperature, 2022, 60 : 159 - 164
  • [47] Numerical model of electron cyclotron resonance ion source
    Mironov, V.
    Bogomolov, S.
    Bondarchenko, A.
    Efremov, A.
    Loginov, V.
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2015, 18 (12):
  • [48] Compact electron cyclotron resonance proton ion source
    Boukari, F.
    Wartski, L.
    Roy, V.
    Schwebel, C.
    Coste, Ph.
    Aubert, J.
    Review of Scientific Instruments, 1996, 67 (3 pt 2):
  • [49] Measurement of the energy distribution of electrons escaping confinement from an electron cyclotron resonance ion source
    Isherwood, Bryan
    Machicoane, Guillaume
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (02):