Preparation of matrix-matched standards for the analysis of teeth via laser ablation-inductively coupled plasma-mass spectrometry

被引:3
|
作者
Westerhausen, Mika T. [1 ]
Bernard, Martin [1 ]
Choi, Gina [1 ]
Jeffries-Stokes, Christine [2 ]
Chandrajith, Rohana [3 ]
Banati, Richard [4 ,5 ]
Bishop, David P. [1 ]
机构
[1] Univ Technol Sydney, Fac Sci, Sch Math & Phys Sci, Hyphenated Mass Spectrometry Lab HyMaS, POB 123, Broadway, NSW 2007, Australia
[2] Rural Clin Sch Western Australia, Kalgoorlie, WA 6433, Australia
[3] Univ Peradeniya, Fac Sci, Dept Geol, Peradeniya, Sri Lanka
[4] Australian Nucl Sci & Technol Org, New Illawarra Rd, Lucas Heights, NSW 2234, Australia
[5] Univ Sydney, Fac Med & Hlth, 94 Mallett St, Camperdown, NSW 2050, Australia
关键词
LA-ICP-MS; HUMAN TOOTH ENAMEL; DENTIN; DISTRIBUTIONS; CHEMISTRY; THICKNESS; EXPOSURE; LEAD;
D O I
10.1039/d2ay02015g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mineralised tissue such as teeth can serve as a retrospective, chronological bioindicator of past exposure to toxic metals. Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) can be used to determine the presence and spatial distribution of toxic metals in teeth, giving a record of when an exposure occurred. Concentrations of these metals are often determined by a one-point calibration against NIST glass using an equation that requires an internal standard factor that accounts for differences in ablation behaviour between the glass and the tooth. However, an ideal external calibration would contain multiple matrix-matched standards to obtain a calibration curve. Here, we investigated optimal procedures for preparing synthetic hydroxyapatite (HA) doped with elements of interest as a calibration material. The materials were examined for homogeneity of metal incorporation, matrix-matched ablation characteristics, linearity, and limits of detection. A homogenised and pelleted HA was the most suitable material, providing improved ablation characteristics over previous HA materials and NIST glass for the analysis of teeth. An ablation yield of 1.1 showed its suitability to analyse teeth, the metals were homogeneously incorporated, and it produced excellent linearity with limits of detection ranging from 0.1-2 mu g kg(-1) for magnesium, aluminium, nickel, copper, zinc, cadmium, barium and lead. A juvenile incisor from a remote indigenous community in Australia and an adult molar from Sri Lanka were assessed for toxic metal exposure. The molar showed evidence of exposure to cadmium and lead. The synthetic HA material was straightforward to prepare, and will improve confidence in the analysis of teeth and other biomineralised material when assessing toxic metal exposure.
引用
收藏
页码:797 / 806
页数:10
相关论文
共 50 条
  • [21] Development of a Matrix-Matched Sphalerite Reference Material (MUL-ZnS-1) for Calibration of In Situ Trace Element Measurements by Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry
    Onuk, Peter
    Melcher, Frank
    Mertz-Kraus, Regina
    Gaebler, Hans-Eike
    Goldmann, Simon
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2017, 41 (02) : 263 - 272
  • [22] ANALYSIS OF DIAMONDS AND INDICATOR MINERALS FOR DIAMOND EXPLORATION BY LASER ABLATION-INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY
    WATLING, RJ
    HERBERT, HK
    BARROW, IS
    THOMAS, AG
    ANALYST, 1995, 120 (05) : 1357 - 1364
  • [23] Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry Analysis Applied to the Characterization of Peruvian Wari Ceramics
    Dussubieux, Laure
    Golitko, Mark
    Williams, Patrick Ryan
    Speakman, Robert J.
    ARCHAEOLOGICAL CHEMISTRY: ANALYTICAL TECHNIQUES AND ARCHAEOLOGICAL INTERPRETATION, 2007, 968 : 349 - 363
  • [24] ANALYSIS OF ROCKS, SOILS AND SEDIMENTS FOR THE CHALCOPHILE ELEMENTS BY LASER ABLATION-INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY
    GUO, X
    LICHTE, FE
    ANALYST, 1995, 120 (11) : 2707 - 2711
  • [25] Elemental bio-imaging of trace elements in teeth using laser ablation-inductively coupled plasma-mass spectrometry
    Hare, Dominic
    Austin, Christine
    Doble, Philip
    Arora, Manish
    JOURNAL OF DENTISTRY, 2011, 39 (05) : 397 - 403
  • [26] Role of laser ablation-inductively coupled plasma-mass spectrometry in cultural heritage research: A review
    Giussani, Barbara
    Monticelli, Damiano
    Rampazzi, Laura
    ANALYTICA CHIMICA ACTA, 2009, 635 (01) : 6 - 21
  • [27] Development and Validation of a Matrix-Matched Assay to Measure Iodine in Serum by Inductively Coupled Plasma-Mass Spectrometry
    Haglock, C. J.
    Strathmann, F. G.
    THERAPEUTIC DRUG MONITORING, 2013, 35 (05) : 720 - 721
  • [28] Elemental Bioimaging by Means of Fast Scanning Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry
    Karst, Uwe (uk@uni-muenster.de), 1600, Springer Science and Business Media, LLC (26):
  • [29] An open, non-contact cell for laser ablation-inductively coupled plasma-mass spectrometry
    Asogan, Dhinesh
    Sharp, Barry L.
    O'Connor, Ciaran J. P.
    Green, Damon A.
    Hutchinson, Robert W.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (07) : 917 - 923
  • [30] Elemental Bioimaging by Means of Fast Scanning Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry
    Wehe, Christoph A.
    Thyssen, Georgina M.
    Herdering, Christina
    Raj, Indra
    Ciarimboli, Giuliano
    Sperling, Michael
    Karst, Uwe
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2015, 26 (08) : 1274 - 1282