Calculation method of external fault short-circuit current for variable-speed pumped storage units based on time-domain dynamic circuit

被引:0
|
作者
He, Rufei [1 ]
Lu, Qinghui [2 ]
Ma, Yiming [1 ]
Qiao, Jian [2 ]
Li, Yongqi [1 ]
Peng, Yumin [1 ]
Yin, Xianggen [2 ]
Li, Yao [1 ]
机构
[1] CSG PGC Power Storage Res Inst, Guangzhou, Peoples R China
[2] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Technol, Wuhan, Peoples R China
关键词
variable-speed pumped storage units; external faults; short-circuit current; jumper; dynamic circuit; dynamic characteristics; DFIG; CONVERTERS; TURBINE; PLANTS;
D O I
10.3389/fenrg.2023.1331512
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The calculation method of the external fault short-circuit current of large units with clear mechanisms and practicality is of great value in engineering practice. Due to the special AC excitation structure and control mode, the external fault short-circuit characteristics of variable-speed pumped storage units (VSPSUs) are very different from those of conventional units. Therefore, this paper proposes a calculation method for external fault short-circuit current based on a time-domain dynamic circuit. According to the excitation and control characteristics of VSPSUs under external fault, the VSPSU under external fault is divided into two cases: continuous excitation and jumper action. Based on space vector analysis, the time-domain dynamic circuit models are established, respectively. On this basis, the analytical formula of the external fault short-circuit current of VSPSUs is derived by combining the transition boundary conditions of the two cases and the dynamic characteristics of the stator flux linkage. Finally, the comparison with PSCAD/EMTDC simulation results shows that the proposed VSPSUs' external fault short-circuit current calculation method has high accuracy and practical value, which can meet the needs of primary equipment selection and relay protection of variable-speed pumped storage power plants.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Stator winding short-circuit fault detection in a permanent magnet synchronous motor (PMSM) using negative sequence current in time domain
    Quiroga, Jabid E.
    INGENIERIA E INVESTIGACION, 2009, 29 (02): : 48 - 52
  • [43] Detection of turn short-circuit fault in PMSM variable speed sensorless vector control based on luenberger observer and adaptive Fuzzy Logic Controller
    Kercha, Safia
    Ameur, Aissa
    Benmiloud, Ismail
    Bechkaoui, Amar
    Linani, Messaoud
    ROMANIAN JOURNAL OF INFORMATION TECHNOLOGY AND AUTOMATIC CONTROL-REVISTA ROMANA DE INFORMATICA SI AUTOMATICA, 2023, 33 (04): : 59 - 68
  • [44] Open-Circuit Fault Identification Method for Interleaved Converters Based on Time-Domain Analysis of the State Observer Residual
    Wassinger, Nicolas
    Penovi, Emiliano
    Garcia Retegui, Rogelio
    Maestri, Sebastian
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (04) : 3740 - 3749
  • [45] A NEW EFFICIENT METHOD FOR CALCULATION AND SUPPRESSION OF SIMULTANEOUS SWITCHING NOISE WITH THE TIME-DOMAIN IMPEDANCE FUNCTION FOR HIGH-SPEED CIRCUIT DESIGN
    Ding, T. -H.
    Li, Y. -S.
    Yan, X.
    Qu, Y. -Z.
    PROGRESS IN ELECTROMAGNETICS RESEARCH-PIER, 2011, 112 : 41 - 62
  • [46] Robust Diagnosis Method Based on Parameter Estimation for an Interturn Short-Circuit Fault in Multipole PMSM under High-Speed Operation
    Lee, Jewon
    Moon, Seokbae
    Jeong, Hyeyun
    Kim, Sang Woo
    SENSORS, 2015, 15 (11) : 29452 - 29466
  • [47] Research on Dynamic and Thermal Effects Based on the Calculation of the Short-Circuit Current in Low-Voltage DC Distribution Systems for Civil Buildings
    Wei, Qiang
    Ni, Gaojun
    Feng, Jianhua
    Ma, Hao
    APPLIED SCIENCES-BASEL, 2023, 13 (20):
  • [48] Multi-timescale analysis and quantification of dynamic regulation characteristics of DFIM-based variable-speed pumped storage units in alleviating wind power fluctuations
    Li, Chaoshun
    Tan, Xiaoqiang
    Lu, Xueding
    Zhu, Zhiwei
    Xu, Rongli
    Liu, Xiaobing
    Wang, Zhengwei
    JOURNAL OF ENERGY STORAGE, 2024, 88
  • [49] The Approximate Method of Three Phase Short-Circuit Current Calculation Based on the Per-Unit Value Form of Ohm's Law
    Wang, YuMei
    Zhang, Zhan
    ADVANCES IN COMPUTER SCIENCE, ENVIRONMENT, ECOINFORMATICS, AND EDUCATION, PT IV, 2011, 217 : 203 - 209
  • [50] Transient Current Based Fault Location Method of Pole-to-pole Short-circuit for Modular Multilevel Converter Low-voltage Direct Current
    Gao X.
    Huang W.
    Tai N.
    Ma Z.
    Wang Y.
    Li C.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (17): : 127 - 135