Novel configuration of dual-temperature condensation and dual-temperature evaporation high-temperature heat pump system: Carbon footprint, energy consumption, and financial assessment

被引:33
|
作者
Dai, Baomin [1 ]
Wang, Qi [1 ]
Liu, Shengchun [1 ]
Wang, Dabiao [2 ]
Yu, Liqi [1 ]
Li, Xinhai [1 ]
Wang, Yuanyuan [1 ]
机构
[1] Tianjin Univ Commerce, Tianjin Key Lab Refrigerat Technol, Tianjin 300134, Peoples R China
[2] Fuzhou Univ, Natl Engn Res Ctr Chem Fertilizer Catalyst NERC CF, Sch Chem Engn, Fujian 350002, Peoples R China
关键词
High-temperature heat pump; Ejector; Dual-temperature condensation; Dual-temperature evaporation; Temperature matching; Waste heat recovery; CO2 REFRIGERATION CYCLE; LOW-GWP REFRIGERANTS; PERFORMANCE ANALYSIS; WORKING; R1234ZE(Z);
D O I
10.1016/j.enconman.2023.117360
中图分类号
O414.1 [热力学];
学科分类号
摘要
To achieve the goal of carbon neutrality for the application of industrial heating by recovery waste heat, the concept of dual-temperature condensation and dual-temperature evaporation is proposed for the hightemperature heat pump (HTHP) by introducing the techniques of ejector and two-stage compression. The energy, exergy, emission, and economic models are developed and optimized for the two new proposed systems. Then, the energy consumption, CO2 emissions and cost (LCC) during the whole life cycle are compared with five existing heat pumps and four traditional boilers. The highest coefficient of performance (COP) of heat pump (HP) can be got when intermediate water temperature on the heat sink side is optimum. The new proposed systems have better performances than the other five HTHPs. During the rated working condition, discharge temperature decreases by the use of dual-temperature condensation and dual-temperature evaporation HP with an ejector (EjDCDE). The optimal COP of Ej-DCDE-2 is 4.25, which is 11.55% and 1.43% higher than dual-temperature condensation and single-temperature evaporation HP and Ej-DCDE-1, respectively. The exergy destruction of Ej-DCDE-2 is reduced by 27.88% compared with basic heat pump (Base). Moreover, Ej-DCDE-2 has the lowest primary energy consumption of 14.62 ktoe, 22.19% and 25.09% lower than Base and oil-fired boiler during the total working period, respectively. In general, HTHPs have lower carbon dioxide, gaseous and particular pollutant emissions compared with boilers, especially Ej-DCDE-2. Finally, Ej-DCDE-2 has the minimum LCC, which is 14.67% and 11.75% less than Base and coal-fired boiler. Ej-DCDE-2 shows the most potential advantages of all the heating solutions and is recommended to replace traditional boilers for industrial heating.
引用
收藏
页数:25
相关论文
共 50 条
  • [21] A NEW DUAL-TEMPERATURE DESIGN METHOD FOR THE SYNTHESIS OF HEAT-EXCHANGER NETWORKS
    TRIVEDI, KK
    ONEILL, BK
    ROACH, JR
    COMPUTERS & CHEMICAL ENGINEERING, 1989, 13 (06) : 667 - 685
  • [22] Theoretical Performance Analysis of an Ejector Enhanced High-Temperature Heat Pump with Dual-Pressure Condensation and Evaporation
    Tao Bai
    Ye Liu
    Gang Yan
    Jianlin Yu
    Journal of Thermal Science, 2022, 31 : 1367 - 1379
  • [23] Theoretical Performance Analysis of an Ejector Enhanced High-Temperature Heat Pump with Dual-Pressure Condensation and Evaporation
    Bai Tao
    Liu Ye
    Yan Gang
    Yu Jianlin
    JOURNAL OF THERMAL SCIENCE, 2022, 31 (05) : 1367 - 1379
  • [24] Theoretical Performance Analysis of an Ejector Enhanced High-Temperature Heat Pump with Dual-Pressure Condensation and Evaporation
    BAI Tao
    LIU Ye
    YAN Gang
    YU Jianlin
    Journal of Thermal Science, 2022, 31 (05) : 1367 - 1379
  • [25] Enhancing energy efficiency of electronics factories with dual-temperature chilled water systems
    Wang, F.-J. (fjwang@ncut.edu.tw), 1600, National Taiwan University of Science and Technology (28):
  • [26] IMPROVED DUAL-TEMPERATURE SYSTEM FOR HYDROGEN ISOTOPE-SEPARATION FROM WATER
    ASAKURA, Y
    UCHIDA, S
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1982, 41 : 240 - 241
  • [27] Pre-clinical assessment of a dual-temperature operated heated tobacco product
    Cava, G.
    O'Connell, G.
    Pani, J.
    Dethloff, O.
    Wieczorek, R.
    Sticken, E. Trelles
    Thompson, J.
    TOXICOLOGY LETTERS, 2019, 314 : S172 - S173
  • [28] Experimental Study on Intermittent Operation Characteristics of Zeotropic Mixture Partial Condensation Based Dual-temperature Refrigeration System
    Chen, Qi
    Yan, Gang
    Wu, Qingping
    Yu, Jianlin
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2022, 43 (07): : 1815 - 1823
  • [29] Design of district heating system with dual-temperature supply based on thermal energy discretisation and matching method
    Chen, Wei
    Li, Tiancheng
    Li, Xianting
    Wang, Baolong
    Cao, Yang
    Shi, Wenxing
    JOURNAL OF CLEANER PRODUCTION, 2023, 421
  • [30] Dual-pressure condensation high temperature heat pump system for waste heat recovery: Energetic and exergetic assessment
    Dai, Baomin
    Liu, Xiao
    Liu, Shengchun
    Zhang, Yingying
    Zhong, Dan
    Feng, Yining
    Nian, Victor
    Hao, Ying
    ENERGY CONVERSION AND MANAGEMENT, 2020, 218