Horizontal flow aerated constructed wetlands for municipal wastewater treatment: The influence of bed depth

被引:7
|
作者
Pascual, A. [1 ]
Alvarez, J. A. [2 ]
de la Varga, D. [3 ]
Arias, C. A. [4 ]
Van Oirschot, D. [5 ]
Kilian, R. [6 ]
Soto, M. [1 ]
机构
[1] Univ A Coruna, Dept Chem, La Coruna, Spain
[2] AIMEN, Pontevedra, Spain
[3] Sedaqua, La Coruna, Spain
[4] Aarhus Univ, Dept Biol, Aarhus, Denmark
[5] Rietland bvba, Hoogstraten, Belgium
[6] Kilian Water, Bryrup, Denmark
关键词
Constructed wetlands; Aeration; Bed depth; Nitrification-denitrification; Total nitrogen; REMOVAL; EMISSIONS; DYNAMICS; METHANE;
D O I
10.1016/j.scitotenv.2023.168257
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The influence of bed depth on the performance of aerated horizontal constructed wetlands was investigated at the pilot plant scale. Two horizontal flow subsurface constructed wetlands (HF) intensified units of different bed depth (HF1: 0.90 m and HF2: 0.55 m, 0.8 m and 0.5 m water level, respectively) were fitted with forced aeration, while a third one (HFc, 0.55 m bed depth, 0.5 m water level) was used as control and not aerated. The three HF units were operated in parallel, receiving the same municipal wastewater pre-treated in a hydrolytic up-flow sludge blanket anaerobic digester. Applied surface loading rates (SLR) ranged from 20 to 80 g biochemical oxygen demand (BOD5)/m2 & sdot;d and from 3.7 to 6.7 g total nitrogen (TN)/m2 & sdot;d, while it ranges from 6 to 23 g BOD5/m2 & sdot;d and from 1.1 to 1.7 g TN/m2 & sdot;d in the control unit. Removal of total suspended solids (TSS) and BOD5 was usually close to a 100 % in all units, whilst chemical oxygen demand (COD) removal was higher for the HF1 unit (97 % on average, range of 96-99 %) than for HF2 (92 %, 82-98 %) and HFc (94 %, 86-99 %). TN removal reached on average 33 % (16-43 %) in HFc, 37 % (10-76 %) in HF2 and 51 % (21-79 %) in HF1. High TN removal required a longer aeration time for nitrification and higher effluent recirculation ratio to enhance denitrification. The results indicate that artificial aeration and a high bed depth allows to increase the SLR by a factor of 4 in HF1 but only by a factor of 2 in HF2.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Performance evaluation of horizontal flow constructed wetlands as primary and secondary treatment for university campus wastewater
    Tan, Yee Yong
    Tang, Fu Ee
    Ho, Carrie Lee Ing
    Wong, Madeline Shu Zhen
    2ND INTERNATIONAL CONFERENCE ON MATERIALS TECHNOLOGY AND ENERGY, 2020, 943
  • [22] Performance Evaluation of Horizontal Subsurface Flow-Constructed Wetlands for the Treatment of Domestic Wastewater in the Tropics
    Mburu, Njenga
    Tebitendwa, Sylvie M.
    Rousseau, Diederik P. L.
    van Bruggen, J. J. A.
    Lens, Piet N. L.
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2013, 139 (03) : 358 - 367
  • [23] BPA and NP removal from municipal wastewater by tropical horizontal subsurface constructed wetlands
    Toro-Velez, A. F.
    Madera-Parra, C. A.
    Pena-Varon, M. R.
    Lee, W. Y.
    Bezares-Cruz, J. C.
    Walker, W. S.
    Cardenas-Henao, H.
    Quesada-Calderon, S.
    Garcia-Hernandez, H.
    Lens, P. N. L.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2016, 542 : 93 - 101
  • [24] The use of Vertical Flow Constructed Wetlands in Wastewater Treatment
    Tsihrintzis, Vassilios A.
    WATER RESOURCES MANAGEMENT, 2017, 31 (10) : 3245 - 3270
  • [25] The use of Vertical Flow Constructed Wetlands in Wastewater Treatment
    Vassilios A. Tsihrintzis
    Water Resources Management, 2017, 31 : 3245 - 3270
  • [26] Performances of constructed wetlands for municipal wastewater treatment in rural mountainous area
    Gérard Merlin
    Jean-Luc Pajean
    Thierry Lissolo
    Hydrobiologia, 2002, 469 : 87 - 98
  • [27] Performances of constructed wetlands for municipal wastewater treatment in rural mountainous area
    Merlin, G
    Pajean, JL
    Lissolo, T
    HYDROBIOLOGIA, 2002, 469 (1-3) : 87 - 98
  • [28] Thirty years of constructed wetlands for municipal wastewater treatment in the Czech Republic
    Vymazal, Jan
    ECOLOGICAL ENGINEERING, 2023, 194
  • [29] Municipal wastewater treatment by sequential combination of photocatalytic oxidation with constructed wetlands
    Antoniadis, A.
    Takavakoglou, V.
    Zalidis, G.
    Darakas, E.
    Poulios, I.
    CATALYSIS TODAY, 2010, 151 (1-2) : 114 - 118
  • [30] Treatment of presettled municipal wastewater using a passively aerated vertical bed
    Admon, S
    Tarre, S
    Sabbah, I
    Lahav, O
    Beliavski, M
    Green, M
    ENVIRONMENTAL ENGINEERING SCIENCE, 2005, 22 (06) : 707 - 715