Signal Preprocessing for Heartbeat Detection Using Continuous-Wave Doppler Radar

被引:3
|
作者
Lee, In-Seong [1 ]
Yang, Jong-Ryul [1 ,2 ]
机构
[1] Yeungnam Univ, Dept Elect Engn, Gyongsan 38541, South Korea
[2] Konkuk Univ, Dept Elect & Elect Engn, Seoul 05029, South Korea
来源
关键词
Heart beat; Signal resolution; Doppler radar; Time-frequency analysis; Time measurement; Signal processing; Monitoring; Continuous-wave (CW) radar; detrending technique; heartbeat monitoring; vital signs; window size; ACCURACY;
D O I
10.1109/LMWT.2022.3228328
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A signal preprocessing method is proposed for effectively monitoring heartbeats from signals obtained using a continuous-wave (CW) Doppler radar. The proposed method consists of windowing with a size optimized for heartbeat detection, detrending to minimize the effect of dc drift, and data reconstruction to increase the fast Fourier transform (FFT) resolution. A window size of 3 s effectively extracts the heartbeat alone from the received signals of the CW radar, which comprised respiration, motion, and heartbeat signals. The effect of the low-frequency noise caused by the internal heat generation of hardware components is reduced by the detrending technique, and the low resolution of the FFT, due to a small number of samples, is improved through reconstruction by combining data from three windows. The signal-to-noise ratio of the measured waveform was improved to 5.83 dB using the proposed method in a 5.8-GHz CW radar. For the data acquired for 60 s, the proposed method showed a heartbeat detection accuracy of 95.8% by using a signal processing time 13% lower than that of the conventional method.
引用
收藏
页码:479 / 482
页数:4
相关论文
共 50 条
  • [41] 915-MHz Continuous-Wave Doppler Radar Sensor for Detection of Vital Signs (vol 8, 561, 2019)
    Park, Jae-Hyun
    Jeong, Yeo-Jin
    Lee, Ga-Eun
    Oh, Jun-Taek
    Yang, Jong-Ryul
    ELECTRONICS, 2019, 8 (08)
  • [42] Non-contact monitoring of human heartbeat signals using mm-wave frequency-modulated continuous-wave radar under low signal-to-noise ratio conditions
    Zhang, Wenyu
    Li, Gang
    Wang, Zetao
    Wu, Hao
    IET RADAR SONAR AND NAVIGATION, 2022, 16 (03): : 456 - 469
  • [43] Instantaneous Heartbeat Detection using a Cross-Correlation based Template Matching for Continuous Wave Radar Systems
    Will, Christoph
    Shi, Kilin
    Lurz, Fabian
    Weigel, Robert
    Koelpin, Alexander
    2016 IEEE TOPICAL CONFERENCE ON WIRELESS SENSORS AND SENSOR NETWORKS (WISNET), 2016, : 31 - 34
  • [44] FHR SIGNAL LOSS USING CONTINUOUS-WAVE DOPPLER ULTRASOUND TELEMETRY WITH AUTOCORRELATION IN PREGNANCY AND DURING AMBULANT LABOR
    SPENCER, JAD
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1987, 94 (05): : 488 - 489
  • [45] A continuous-wave (CW) radar for gait analysis
    Geisheimer, JL
    Marshall, WS
    Greneker, E
    CONFERENCE RECORD OF THE THIRTY-FIFTH ASILOMAR CONFERENCE ON SIGNALS, SYSTEMS AND COMPUTERS, VOLS 1 AND 2, 2001, : 834 - 838
  • [46] TURBULENCE INDEX MEASURED BY CONTINUOUS-WAVE DOPPLER EXAMINATION IN THE DETECTION OF CAROTID STENOSIS
    LEVIEN, LJ
    SOUTH AFRICAN JOURNAL OF SURGERY, 1982, 20 (03) : 173 - 174
  • [47] THE DETECTION OF INTRACRANIAL CAROTID-ARTERY DISEASE BY CONTINUOUS-WAVE DOPPLER SONOGRAPHY
    BIEDERT, S
    WINTER, R
    BETZ, H
    REUTHER, R
    NEURORADIOLOGY, 1986, 28 (04) : 296 - 303
  • [48] Signal model and imaging algorithm for spaceborne interrupted continuous-wave synthetic aperture radar
    Liu, Y.
    Deng, Y. K.
    Wang, R.
    Wang, X.
    IET RADAR SONAR AND NAVIGATION, 2012, 6 (05): : 348 - 358
  • [49] A contactless approach for respiratory gating in PET using continuous-wave radar
    Ersepke, Thomas
    Buether, Florian
    Hess, Mirco
    Schaefers, Klaus P.
    MEDICAL PHYSICS, 2015, 42 (08) : 4911 - 4919
  • [50] System Architecture and Signal Processing for Frequency-Modulated Continuous-Wave Radar Using Active Backscatter Tags
    Gu, Jian-Feng
    Wang, Kuangda
    Wu, Ke
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2018, 66 (09) : 2258 - 2272