Retrofitting of squat RC column by using TRM strip under axial load

被引:6
|
作者
Mercimek, Omer [1 ]
Celik, Alper [2 ]
Ghoroubi, Rahim [3 ]
Anil, Ozgur [4 ]
机构
[1] Ankara Univ, Civil Eng Dept, Ankara, Turkiye
[2] Erzincan Binali Yildirim Univ, Civil Eng Dept, Erzincan, Turkiye
[3] Univ Calif Davis, Civil & Environm Engn, Davis, CA USA
[4] Gazi Univ, Civil Eng Dept, Ankara, Turkiye
关键词
RC column; TRM strip; Retrofitting; Axial load; Anchor; External jacketing; TEXTILE-REINFORCED MORTAR; CONCRETE COLUMNS; CFRP; FRCM; BEHAVIOR; FRP; CONFINEMENT; PERFORMANCE; STRENGTH; ELEMENTS;
D O I
10.1016/j.istruc.2024.105909
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study investigates the retrofitting of reinforced concrete columns with TRM strips. Seventeen test specimens were produced, and one was chosen as a reference test specimen. Damaged by loading up to 50% of their maximum axial load-carrying capacity test specimens were retrofitted with two different carbon textiles. In addition to the textile type, TRM strip width, strip spacing, and the use of anchors were determined as experimental variables. Maximum bearing capacity, displacement at bearing capacity, initial stiffness, displacement ductility ratio, and energy consumption capacity were calculated using the axial load-displacement graphs obtained from the experimental study. Depending on the obtained results, the effects of experimental variables on the behavior of damaged reinforced concrete columns were interpreted and compared. It has been determined that the retrofitting method presents very successful results. It has been observed that the fan-type anchor, which is rarely used in literature studies, significantly increases the maximum bearing capacity and energy consumption capacity values of test specimens. Finally, the experimental results were compared with those obtained from the numerical models created by the ABAQUS finite element software.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] RC BEAM-COLUMN JOINTS UNDER LARGE LOAD REVERSALS
    Lee, Duane L.N.
    Wight, James K.
    Hanson, Robert D.
    1977, 103 (12): : 2337 - 2350
  • [22] Connections between RC beam and square tubed-RC column under axial compression: Experiments
    Zhou, Xu-Hong
    Li, Bin-Yang
    Gan, Dan
    Liu, Jie-Peng
    Chen, Y. Frank
    STEEL AND COMPOSITE STRUCTURES, 2017, 23 (04): : 453 - 464
  • [23] Nonlinear response of RC column models under real earthquakes and axial loads
    Guri, Zijadin
    Ristic, Jelena
    Ristic, Danilo
    GRADEVINAR, 2024, 76 (10): : 919 - 930
  • [24] Determination of Critical Load in a Nonuniform Circular Steel Column under the Eccentric Axial Load
    Kotsmid, Stanislav
    Kuo, Chang-Hung
    Beno, Pavel
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2016, 2016
  • [25] Numerical study on effect of constant and variable axial loads on RC column subjected to blast load
    Abebe, Solomon
    Getachew, Solomon
    HELIYON, 2022, 8 (11)
  • [26] Influence of axial load on the seismic behavior of RC beam-column joints with wide beam
    Masi, Angelo
    Santarsiero, Giuseppe
    Mossucca, Antonello
    Nigro, Domenico
    Applied Mechanics and Materials, 2014, 508 : 208 - 214
  • [27] HELICAL POSTBUCKLING CONFIGURATION OF A WEIGHTLESS COLUMN UNDER THE ACTION OF AN AXIAL LOAD
    CHEATHAM, JB
    PATTILLO, PD
    SOCIETY OF PETROLEUM ENGINEERS JOURNAL, 1984, 24 (04): : 467 - 472
  • [28] Experimental investigation on structural behaviour of castellated column under axial load
    Patil R.A.
    Salgar P.B.
    Asian Journal of Civil Engineering, 2024, 25 (6) : 4645 - 4655
  • [29] Evaluation of seismic performance of RC beam-column system using slit brace retrofitting
    Kim, Min Sook
    Lee, Young Hak
    STRUCTURES, 2025, 71
  • [30] Retrofitting of pinned beam–column connections in RC precast frames using lead extrusion dampers
    Cihan Soydan
    Ercan Yüksel
    Erdal İrtem
    Bulletin of Earthquake Engineering, 2018, 16 : 1273 - 1292