Response of current distribution in a liter-scale microbial fuel cell to variable operating conditions

被引:1
|
作者
Zhang, Yudong [1 ,2 ,3 ]
Li, Dong [1 ,2 ]
Zhang, Liang [1 ,2 ]
Li, Jun [1 ,2 ]
Fu, Qian [1 ,2 ]
Zhu, Xun [1 ,2 ]
Liao, Qiang [1 ,2 ]
机构
[1] Chongqing Univ, Key Lab Low Grade Energy Utilizat Technol & Syst, Minist Educ, Chongqing, Peoples R China
[2] Chongqing Univ, Inst Engn Thermophys, Sch Energy & Power Engn, Chongqing 400030, Peoples R China
[3] North Univ China, Sch Energy & Power Engn, Taiyuan 030051, Peoples R China
基金
中国国家自然科学基金;
关键词
Microbial fuel cells; Scale-up; Response of current distribution; Operating conditions; POWER-GENERATION; PERFORMANCE; MFC; TEMPERATURE; RESISTANCE; RECOVERY;
D O I
10.1016/j.bioelechem.2023.108622
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Microbial fuel cells (MFCs) are an emerging technology in renewable energy and waste treatment and the scaleup is crucial for practical applications. Undoubtedly, the analysis and comprehension of MFC operation necessitate essential information regarding the response of the current distribution to variable operating conditions, which stands as one of its significant dynamic characteristics. In this study, the dynamic responses of current distribution to external stimuli (external load, temperature, pH, and electrolyte concentration) were investigated by employing a segmented anode current collector in a literscale MFC. The results demonstrated that, with respect to the anodic segment close to the cathode, a major response of the segment current to changes in load, temperature and pH was observed while minor response to changes in ion concentration. It was also found that external stimuli-induced high current usually led to a worse current distribution while increasing electrolyte ion concentration could simultaneously improve the maximal power generation and current distribution. In addition, the response time of segment current to input stimulus followed the pattern of temperature > pH > ion concentration > external load. The results and implication of this study would be helpful in enhancing the operational stability of scale-up MFCs in future practical application.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] CURRENT DISTRIBUTION IN A POLYMER ELECTROLYTE MEMBRANE FUEL CELL UNDER FLOODING CONDITIONS
    Jamekhorshid, A.
    Karimi, G.
    Li, X.
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON FUEL CELL SCIENCE, ENGINEERING, AND TECHNOLOGY, 2009, : 387 - 393
  • [32] Polyelectrolyte microparticles for enhancing anode performance in an air-cathode μ-Liter microbial fuel cell
    Chen, Yan-Yu
    Wang, Hsiang-Yu
    APPLIED ENERGY, 2015, 160 : 965 - 972
  • [33] Comparative Assessment of Microbial-Fuel-Cell Operating Parameters
    Anam, Maira
    Yousaf, Sameen
    Ali, Naeem
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2020, 146 (09)
  • [34] A miniature microbial fuel cell operating with an aerobic anode chamber
    Ringeisen, Bradley R.
    Ray, Ricky
    Little, Brenda
    JOURNAL OF POWER SOURCES, 2007, 165 (02) : 591 - 597
  • [35] Comparative Assessment of Microbial-Fuel-Cell Operating Parameters
    Anam, Maira
    Yousaf, Sameen
    Ali, Naeem
    Journal of Environmental Engineering (United States), 2020, 146 (09):
  • [37] Distribution measurements in an operating polymer electrolyte fuel cell
    Mench, MM
    Dong, QL
    Wang, CY
    Proton Conducting Membrane Fuel Cells III, Proceedings, 2005, 2002 (31): : 183 - 197
  • [38] Application of a five level central composite design to optimize operating conditions for electricity generation in a microbial fuel cell
    Alshehria, Abdullah N. Z.
    Ghanem, Khaled M.
    Al-Garni, Saleh M.
    JOURNAL OF TAIBAH UNIVERSITY FOR SCIENCE, 2016, 10 (06): : 797 - 804
  • [39] Effect of ambient conditions on performance and current distribution of a polymer electrolyte membrane fuel cell
    Hottinen, T.
    Noponen, M.
    Mennola, T.
    Himanen, O.
    Mikkola, M.
    Lund, P.
    Journal of Applied Electrochemistry, 1600, 33 (3-4): : 265 - 271
  • [40] Effect of ambient conditions on performance and current distribution of a polymer electrolyte membrane fuel cell
    T. Hottinen
    M. Noponen
    T. Mennola
    O. Himanen
    M. Mikkola
    P. Lund
    Journal of Applied Electrochemistry, 2003, 33 : 265 - 271