Standardized viscosity as a source of error in computational fluid dynamic simulations of cerebral aneurysms

被引:3
|
作者
Fillingham, Patrick [1 ]
Belur, Neethi [1 ]
Sweem, Rebecca [1 ]
Barbour, Michael C. [2 ]
Marsh, Laurel M. M. [2 ]
Aliseda, Alberto [2 ]
Levitt, Michael R. [1 ,2 ,3 ]
机构
[1] Univ Washington, Dept Neurol Surg, Seattle, WA 98195 USA
[2] Univ Washington, Dept Mech Engn, Seattle, WA USA
[3] Univ Washington, Dept Radiol, Seattle, WA USA
关键词
cerebral aneurysm; computational fluid dynamics; viscosity; BLOOD-VISCOSITY; MODELS; FLOW; RHEOLOGY;
D O I
10.1002/mp.16926
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundComputational fluid dynamics (CFD) simulations are a powerful tool for studying cerebral aneurysms, capable of evaluating hemodynamics in a way that is infeasible with imaging alone. However, the difficulty of incorporating patient-specific information and inherent obstacles of in vivo validation have limited the clinical usefulness of CFD of cerebral aneurysms. In this work we investigate the effect of using standardized blood viscosity values in CFD simulations of cerebral aneurysms when compared to simulations of the same aneurysms using patient-specific viscosity values derived from hematocrit measurements.PurposeThe objective of this work is to determine the level of error, on average, that is, caused by using standardized values of viscosity in CFD simulations of cerebral aneurysms. By quantifying this error, we demonstrate the need for incorporating patient-specific viscosity in future CFD investigations of cerebral aneurysms.MethodsCFD simulations of forty-one cerebral aneurysms were conducted using patient-specific boundary conditions. For each aneurysm two simulations were conducted, one utilizing patient-specific blood viscosity derived from hematocrit measurements and another using a standardized value for blood viscosity. Hemodynamic parameters such as wall shear stress (WSS), wall shear stress gradient (WSSG), and the oscillatory shear index (OSI) were calculated for each of the simulations for each aneurysm. Paired t-tests for differences in the time-averaged maps of these hemodynamic parameters between standardized and patient-specific viscosity simulations were conducted for each aneurysm. Bland-Altman analysis was used to examine the cohort-wide changes in the hemodynamic parameters. Subjects were broken into two groups, those with higher than standard viscosity and those with lower than standard viscosity. An unpaired t-test was used to compare the percent change in WSS, WSSG, and OSI between patient-specific and standardized viscosity simulations for the two cohorts. The percent changes in hemodynamic parameters were correlated against the direction and magnitude of percent change in viscosity, aneurysm size, and aneurysm location. For all t-tests, a Bonferroni-corrected significance level of 0.0167 was used.Results63.2%, 41.5%, and 48.7% of aneurysms showed statistically significant differences between patient-specific and standardized viscosity simulations for WSS, WSSG, and OSI respectively. No statistically significant difference was found in the percent changes in WSS, WSSG, and OSI between the group with higher than standard viscosity and those with lower than standard viscosity, indicating an increase in viscosity can cause either an increase or decrease in each of the hemodynamic parameters. On a study-wide level no significant bias was found in either direction for WSS, WSSG, or OSI between the simulation groups due to the bidirectional effect of changing viscosity. No correlation was found between percent change of viscosity and percent change of WSS, WSSG, or OSI, meaning an after-the-fact correction for patient-specific viscosity is not feasible.ConclusionStandardizing viscosity values in CFD of cerebral aneurysms has a large and unpredictable impact on the calculated WSS, WSSG, and OSI when compared to CFD simulations of the same aneurysms using a patient-specific viscosity. We recommend implementing hematocrit-based patient-specific blood viscosity values for all CFD simulations of cerebral aneurysms.
引用
收藏
页码:1499 / 1508
页数:10
相关论文
共 50 条
  • [41] Computational fluid dynamic simulations on liquid film behaviors at flooding in an inclined pipe
    Chen, Jianye
    Tang, Yuan
    Zhang, Wei
    Wang, Yuchen
    Qiu, Limin
    Zhang, Xiaobin
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2015, 23 (09) : 1460 - 1468
  • [42] Computational fluid dynamic simulations of solidification for enhancing speed of continuous cast copper
    Jones, Thomas D. A.
    Strachan, Richard I.
    Mackie, David M.
    Cooper, Mervyn
    Frame, Brain
    Vorstius, Jan B.
    ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2021, 24 (01): : 92 - 104
  • [43] Computational fluid dynamic simulations of a cavopulmonary assist device for failing Fontan circulation
    Lin, W. C. Patrick
    Doyle, Matthew G.
    Roche, S. Lucy
    Honjo, Osami
    Forbes, Thomas L.
    Amon, Cristina H.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 158 (05): : 1424 - +
  • [44] Computational Fluid Dynamics Simulations of Intracranial Aneurysms at Varying Heart Rates: A "Patient-Specific" Study
    Jiang, Jingfeng
    Strother, Charles
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (09):
  • [45] Reproducibility of the computational fluid dynamic analysis of a cerebral aneurysm monitored over a decade
    Paritala, Phani Kumari
    Anbananthan, Haveena
    Hautaniemi, Jacob
    Smith, Macauley
    George, Antony
    Allenby, Mark
    Mendieta, Jessica Benitez
    Wang, Jiaqiu
    Maclachlan, Liam
    Liang, EeShern
    Prior, Marita
    Yarlagadda, Prasad K. D., V
    Winter, Craig
    Li, Zhiyong
    SCIENTIFIC REPORTS, 2023, 13 (01):
  • [46] Reproducibility of the computational fluid dynamic analysis of a cerebral aneurysm monitored over a decade
    Phani Kumari Paritala
    Haveena Anbananthan
    Jacob Hautaniemi
    Macauley Smith
    Antony George
    Mark Allenby
    Jessica Benitez Mendieta
    Jiaqiu Wang
    Liam Maclachlan
    EeShern Liang
    Marita Prior
    Prasad K. D. V. Yarlagadda
    Craig Winter
    Zhiyong Li
    Scientific Reports, 13 (1)
  • [47] Computational fluid dynamic modeling of cerebral blood flow during carotid occlusion
    Charbel, FT
    Clark, ME
    Misra, M
    Alp, MS
    Nabhani, T
    Aletich, V
    Debrun, G
    STROKE, 1998, 29 (01) : 281 - 281
  • [48] Interactive Decomposition and Mapping of Saccular Cerebral Aneurysms Using Harmonic Functions: Its First Application With "Patient-Specific" Computational Fluid Dynamics (CFD) Simulations
    Jiang, Jingfeng
    Strother, Charles M.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (02) : 153 - 164
  • [49] Onset and nature of flow-induced vibrations in cerebral aneurysms via fluid–structure interaction simulations
    David A. Bruneau
    Kristian Valen-Sendstad
    David A. Steinman
    Biomechanics and Modeling in Mechanobiology, 2023, 22 : 761 - 771
  • [50] Clear Detection of Thin-Walled Regions in Unruptured Cerebral Aneurysms by Using Computational Fluid Dynamics
    Kimura, Hidehito
    Taniguchi, Masaaki
    Hayashi, Kosuke
    Fujimoto, Yosuke
    Fujita, Youichi
    Sasayama, Takashi
    Tomiyama, Akio
    Kohmura, Eiji
    WORLD NEUROSURGERY, 2019, 121 : E287 - E295