Non-invasive imaging of neural activity with magnetic detection electrical impedance tomography (MDEIT): a modelling study

被引:7
|
作者
Mason, Kai [1 ]
Aristovich, Kirill [1 ]
Holder, David [1 ]
机构
[1] UCL, Dept Med Phys & Biomed Engn, Gower St, London, England
基金
英国工程与自然科学研究理事会;
关键词
impedance imaging; tomography; neural imaging; magnetometry; human; non-invasive; NEURONAL DEPOLARIZATION; EVOKED RESPONSES; HUMAN HEAD; EIT; RECONSTRUCTION; BRAIN; MAGNETOENCEPHALOGRAPHY; FIELD;
D O I
10.1088/1361-6579/ad0358
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objectives. (1) Develop a computational pipeline for three-dimensional fast neural magnetic detection electrical impedance tomography (MDEIT), (2) determine whether constant current or constant voltage is preferable for MDEIT, (3) perform reconstructions of simulated neural activity in a human head model with realistic noise and compare MDEIT to EIT and (4) perform a two-dimensional study in a saline tank for MDEIT with optically pumped magnetometers (OPMs) and compare reconstruction algorithms. Approach. Forward modelling and image reconstruction were performed with a realistic model of a human head in three dimensions and at three noise levels for four perturbations representing neural activity. Images were compared using the error in the position and size of the reconstructed perturbations. Two-dimensional MDEIT was performed in a saline tank with a resistive perturbation and one OPM. Six reconstruction algorithms were compared using the error in the position and size of the reconstructed perturbations. Main results. A computational pipeline was developed in COMSOL Multiphysics, reducing the Jacobian calculation time from months to days. MDEIT reconstructed images with a lower reconstruction error than EIT with a mean difference of 7.0%, 5.5% and 11% for three noise cases representing current noise, reduced current source noise and reduced current source and magnetometer noise. A rank analysis concluded that the MDEIT Jacobian was less rank-deficient than the EIT Jacobian. Reconstructions of a phantom in a saline tank had a best reconstruction error of 13%, achieved using 0th-order Tikhonov regularisation with simulated noise-based correction. Significance. This study demonstrated that three-dimensional MDEIT for neural imaging is feasible and that MDEIT reconstructed superior images to EIT, which can be explained by the lesser rank deficiency of the MDEIT Jacobian. Reconstructions of a perturbation in a saline tank demonstrated a proof of principle for two-dimensional MDEIT with OPMs and identified the best reconstruction algorithm.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] The Feasibility of Fast Neural Magnetic Detection Electrical Impedance Tomography: A Modelling Study
    Mason, Kai
    Aristovich, Kirill
    Holder, David
    2023 11TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING, NER, 2023,
  • [2] Towards the non-invasive detection of gastroesophageal reflux (GER) by electrical impedance tomography (EIT)?
    Erol, RA
    Cherian, P
    Smallwood, RH
    Brown, BH
    Bardhan, KD
    GASTROENTEROLOGY, 1996, 110 (04) : A57 - A57
  • [3] Non-Invasive Electrical Impedance Tomography for Multi-Scale Detection of Liver Fat Content
    Luo, Yuan
    Abiri, Parinaz
    Zhang, Shell
    Chang, Chih-Chiang
    Kaboodrangi, Amir H.
    Li, Rongsong
    Bui, Alex
    Kumar, Rajesh
    Woo, Mary
    Li, Zhaoping
    Packard, Rene R. Sevag
    Tai, Yu-Chong
    Hsiai, Tzung K.
    THERANOSTICS, 2018, 8 (06): : 1636 - 1647
  • [4] Non-Invasive Hemodynamic Monitoring in Hemodialysis Using Electrical Impedance Tomography
    Oh, Tongin
    Mok, Jinwon
    Moon, Ju Young
    Kim, Yang Gyun
    Lee, Sangho
    Jung, Su Woong
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2022, 33 (11): : 700 - 701
  • [5] Non-invasive coronary imaging: computed tomography or magnetic resonance imaging?
    Peebles, CR
    HEART, 2003, 89 (06) : 591 - 594
  • [6] Direct detection of neural activity in vitro using magnetic resonance electrical impedance tomography (MREIT)
    Sadleir, Rosalind J.
    Fu, Fanrui
    Falgas, Corey
    Holland, Stephen
    Boggess, May
    Grant, Samuel C.
    Woo, Eung Je
    NEUROIMAGE, 2017, 161 : 104 - 119
  • [7] Simulation of 2 Dimensional Non-invasive Electrical Impedance Tomography System for Early Stage Breast Cancer Detection
    Priya Hankare
    Alice N. Cheeran
    SN Computer Science, 6 (3)
  • [8] Non-Invasive Breast Cancer Detection Using Electrical Impedance Tomography: Design, Analysis and Comparison of Reconstruction Algorithms
    Ganesan, Annapoorani
    Durgamahanthi, Vaishali
    TRAITEMENT DU SIGNAL, 2023, 40 (06) : 2809 - 2817
  • [9] Feasibility study of imaging fast neural activity in retinal tissue using Electrical Impedance Tomography
    Zhu, Danyi
    Fang, Xiunan
    Eiber, Calvin
    Avery, James
    Holder, David
    McEwan, Alistair
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 529 - 532
  • [10] Non-invasive determination of absolute lung resistivity in adults using electrical impedance tomography
    Zhang, Jie
    Patterson, Robert
    PHYSIOLOGICAL MEASUREMENT, 2010, 31 (08) : S45 - S56