Lumbar discectomy and fusion: Organs? dose and effective dose estimation using Monte Carlo simulation

被引:0
|
作者
Metaxas, Vasileios [1 ]
Efthymiou, Fotios [1 ]
Dimitroukas, Christos [1 ,2 ]
Delis, Harry [1 ]
Gatzounis, George [3 ,4 ]
Zampakis, Petros [5 ,6 ]
Tzortzidis, Fotios [3 ]
Papadakos, Dimitrios [3 ]
Constantoyannis, Constantine [3 ,4 ]
Panayiotakis, George [1 ,2 ]
机构
[1] Univ Patras, Sch Med, Dept Med Phys, Patras 26504, Greece
[2] Univ Hosp Patras, Dept Med Phys, Patras 26504, Greece
[3] Univ Hosp Patras, Dept Neurosurg, Patras 26504, Greece
[4] Univ Patras, Sch Med, Dept Neurosurg, Patras 26504, Greece
[5] Univ Hosp Patras, Dept Radiol, Patras 26504, Greece
[6] Univ Patras, Sch Med, Dept Radiol, Patras 26504, Greece
关键词
Lumbar discectomy and fusion; Organ dose; Effective dose; VirtualDose-IR; RADIATION-EXPOSURE; PATIENT; REDUCTION; DOSIMETRY; RISKS;
D O I
10.1016/j.apradiso.2023.110781
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In this study, the effect of patient- and procedure-related parameters on organs' dose (OD), peak skin dose (PSD) and effective dose (ED) during lumbar discectomy and fusion (LDF) was assessed. Intra-operative parameters obtained from 102 LDFs were inserted into VirtualDose-IR software implementing sex-specific and BMIadjustable anthropomorphic phantoms for dosimetric calculations. Fluoroscopy time (FT), kerma-area product (KAP), cumulative and incident air-kerma (Kair) were also recorded from the dosimetric report of the mobile Carm. An increase in KAP, Kair, PSD and ED was found for male or higher BMI patients, multi-level or fusion or L5/ S1 procedures. However, a significant difference was found only for PSD and incident Kair between normal and obese patients and for FT between discectomy and discectomy and fusion procedures. The spleen, kidneys and colon received the highest doses. The BMI have a significant impact only for kidneys, pancreas, and spleen doses when comparing obese to overweight and for urinary bladder when comparing overweight to normal patients. Multi-level and fusion procedures resulted in significantly higher doses for lungs, heart, stomach, adrenals, gallbladder and kidneys, while pancreas and spleen doses significantly increased only for multi-level procedures. Additionally, a significant increase was found only for urinary bladder, adrenals, kidneys, and spleen ODs when comparing L5/S1 and L3/L4 levels. The mean ODs were lower compared to the literature. These data may aid neurosurgeons in optimising exposure techniques during LDF to keep patients' dose as low as is practicably possible.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Monte Carlo Based Dose Estimation in Intraoperative Radiotherapy
    Guerra, Pedro
    Gonzalez, Wilfredo
    Ledesma-Carbayo, Maria J.
    Cal-Gonzalez, Jacobo
    Herranz, Elena
    Udias, Jose M.
    Lallena, Antonio
    Santos, Andres
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3069 - 3072
  • [32] Dose estimation of Radiotherapy Based on Monte Carlo Method
    Liu Yanmei
    Xue Dingyu
    Xu Xinhe
    Chen Zhen
    2008 CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1-11, 2008, : 4868 - +
  • [33] Monte Carlo dose index estimation in computed tomography
    Ati, Moncef
    Bouamrane, Rachid
    Addi, Djamel
    Maroc, Fatima Zohra
    Mecheret, Fatima Zohra
    AIMS BIOENGINEERING, 2020, 7 (04): : 224 - 235
  • [34] A Monte Carlo study of impact of scan position for cone beam CT on doses to organs and effective dose
    Abuhaimed, Abdullah
    Martin, Colin J.
    RADIATION PHYSICS AND CHEMISTRY, 2018, 151 : 25 - 35
  • [35] Estimation of absorbed gamma dose rate from granite by Monte Carlo simulation approach
    Knezevic, J.
    Kuzmanovic, P.
    Mrdja, D.
    Todorovic, N.
    Bikit, I
    Hansman, J.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (02) : 596 - 611
  • [36] Monte Carlo simulation for the estimation of the glandular breast dose for a digital breast tomosynthesis system
    Rodrigues, Leonardo
    Goncalves Magalhaes, Luis Alexandre
    Braz, Delson
    RADIATION PROTECTION DOSIMETRY, 2015, 167 (04) : 576 - 583
  • [37] Monte Carlo simulation of single beam dose profile
    LIU Xiaowei
    WEN Guanghao
    LI Mianfeng(Zhongshan University
    Nuclear Science and Techniques, 1999, (02) : 87 - 90
  • [38] Monte carlo simulation of surface percent depth dose
    Lin, SY
    Chu, TC
    Lin, JP
    Huang, CY
    APPLIED RADIATION AND ISOTOPES, 2002, 56 (03) : 505 - 510
  • [39] Estimation of Effective Imaging Dose and Excess Absolute Risk of Secondary Cancer Incidence for 4D-CBCT Using Monte Carlo Simulation
    Yuasa, Y.
    Shiinoki, T.
    Onizuka, R.
    Fujimoto, K.
    Hanazawa, H.
    MEDICAL PHYSICS, 2018, 45 (06) : E386 - E386
  • [40] Inverse dose planning using Monte Carlo
    Alber, M
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S18 - S18