Enhanced Frequency-Constrained Unit Commitment Considering Variable-Droop Frequency Control From Converter-Based Generator

被引:20
|
作者
Yuan, Yiping [1 ]
Zhang, Yao [1 ]
Wang, Jianxue [1 ]
Liu, Zhou [2 ]
Chen, Zhe [3 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
[2] Siemens Gamesa Renewable Energy A S, Siemens Gamesa Res Profess, DK-7330 Copenhagen, Denmark
[3] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
基金
中国国家自然科学基金;
关键词
Generators; Frequency conversion; Power system dynamics; Frequency control; Load modeling; Frequency response; Dispatching; Frequency-constrained unit commitment; variable-droop frequency control; converter-based generators; frequency reserve; mixed-integer linearized constraint; OPTIMAL POWER-FLOW; INERTIAL RESPONSE; SYNTHETIC INERTIA; PROVISION; MODEL; DFIG; PENETRATION; STORAGE; IMPACT; LOAD;
D O I
10.1109/TPWRS.2022.3170935
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To improve the frequency stability of power systems with a high penetration of converter-based generators, this paper proposes an Enhanced Frequency-Constrained Unit Commitment (E-FCUC) considering variable-droop-controlled Frequency Control (FC) from converter-based generators. Unlike previous studies emphasizing conventional and fix-droop converter-based generators participating in primary frequency response, the impact of converter-based generators with variable-droop FC (VD-FC) is investigated, modeled, and then incorporated into the UC problems. Firstly, the transfer function of variable-droop-controlled converter-based generators is modeled; the available primary power reserves bounding provided by converter-based generators is analyzed. Secondly, the frequency dynamic of power systems considering joint frequency control from conventional generators and variable-droop-controlled converter-based generators is derived based on an analytical aggregated System Frequency Response (SFR) model. Since the nonlinear non-smooth feature of obtained frequency dynamic function, the "max-affine" Piece-Wise-Linearization method (PWL) is adopted here to fit the calculated frequency function. The fitting function is subsequently reformulated into mix-integer linearized constraints participating in UC studies. Case studies based on a modified IEEE 6 bus test system and a modified IEEE 118 bus test system are carried out to verify the effectiveness of the proposed E-FCUC through comparisons of results with existing empirical models.
引用
收藏
页码:1094 / 1110
页数:17
相关论文
共 50 条
  • [21] Frequency-constrained Unit Commitments with Linear Rules Extracted from Simulation Results Considering Regulations from Battery Storage
    Zhang, Jiawei
    Chen, Zhichao
    Zhang, Ning
    Zhang, Xianfeng
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2023, 11 (04) : 1041 - 1052
  • [22] Frequency-constrained Unit Commitments with Linear Rules Extracted from Simulation Results Considering Regulations from Battery Storage
    Jiawei Zhang
    Zhichao Chen
    Ning Zhang
    Xianfeng Zhang
    Journal of Modern Power Systems and Clean Energy, 2023, 11 (04) : 1041 - 1052
  • [23] Unit commitment considering the sensitivity of the synchronous generator adjustment coefficient and frequency constraint
    Zhang J.
    Xu G.
    Wang C.
    Bi T.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2023, 51 (13): : 102 - 110
  • [24] Integrated Frequency-constrained Scheduling Considering Coordination of Frequency Regulation Capabilities from Multi-source Converters
    Jiaming Li
    Ying Qiao
    Zongxiang Lu
    Wei Ma
    Xin Cao
    Rongfu Sun
    Journal of Modern Power Systems and Clean Energy, 2024, (01) : 261 - 274
  • [25] Integrated Frequency-constrained Scheduling Considering Coordination of Frequency Regulation Capabilities from Multi-source Converters
    Li, Jiaming
    Qiao, Ying
    Lu, Zongxiang
    Ma, Wei
    Cao, Xin
    Sun, Rongfu
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2024, 12 (01) : 261 - 274
  • [26] Digital Generator Control Unit Design for a Variable Frequency Synchronous Generator in MEA
    Li, Weilin
    Yang, Yang
    Zhang, Xiaobin
    ENERGIES, 2018, 11 (01)
  • [27] Frequency-Constrained Stochastic Planning Towards a High Renewable Target Considering Frequency Response Support From Wind Power
    Li, Hao
    Qiao, Ying
    Lu, Zongxiang
    Zhang, Baosen
    Teng, Fei
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2021, 36 (05) : 4632 - 4644
  • [28] Model-based digital generator control unit for a variable frequency synchronous generator with brushless exciter
    Rosado, Sebastian
    Ma, Xiangfei
    Francis, Gerald
    Wang, Fei
    Boroyevich, Dushan
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2008, 23 (01) : 42 - 52
  • [29] Security-Constrained Unit Commitment Considering Locational Frequency Stability in LowInertia Power Grids
    Tuo, Mingjian
    Li, Xingpeng
    2023 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, PESGM, 2023,
  • [30] Security-constrained unit commitment model considering frequency and voltage stabilities with multiresource participation
    Zidong, Zhou
    Jinquan, Zhao
    FRONTIERS IN ENERGY RESEARCH, 2024, 12