Evaluation of a respiratory motion-corrected image reconstruction algorithm in 2-[18F]FDG and [68Ga]Ga-DOTA-NOC PET/CT: impacts on image quality and tumor quantification

被引:2
|
作者
Meng, Qing-Le [1 ]
Yang, Rui [1 ]
Wu, Run-Ze [2 ]
Xu, Lei [1 ]
Liu, Hao [2 ]
Yang, Gang [2 ]
Dong, Yun [2 ]
Wang, Feng [1 ]
Chen, Zhengguo [3 ]
Jiang, Hongbing [4 ,5 ]
机构
[1] Nanjing Med Univ, Nanjing Hosp 1, Dept Nucl Med, Nanjing, Peoples R China
[2] United Imaging Healthcare, Shanghai, Peoples R China
[3] Univ Elect Sci & Technol China, Mianyang Cent Hosp, Key Lab Nucl Technol Med Transformat, Natl Hlth Commiss,Sch Med, 12 Changjia Lane, Mianyang 621000, Sichuan, Peoples R China
[4] Nanjing Med Univ, Nanjing Hosp 1, Dept Med Equipment, 68 Changle Rd, Nanjing 210006, Peoples R China
[5] Nanjing Emergency Med Ctr, Nanjing, Peoples R China
关键词
Positron emission tomography/computed tomography (PET/CT); elastic respiratory motion correction; motion-corrected image reconstruction (MCIR); image quality; tumor quantification; DIAGNOSTIC-VALUE; GATED PET/CT; REGISTRATION; DELINEATION;
D O I
10.21037/qims-22-557
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Respiratory motions may cause artifacts on positron emission tomography (PET) images that degrade image quality and quantification accuracy. This study aimed to evaluate the effect of a respiratory motion-corrected image reconstruction (MCIR) algorithm on image quality and tumor quantification compared with nongated/nonmotion-corrected reconstruction. Methods: We used a phantom consisting of 5 motion spheres immersed in a chamber driven by a motor. The spheres and the background chamber were filled with 18F solution at a sphere-to-background ratio of 5:1. We enrolled 42 and 16 patients undergoing 2-deoxy-2-[F-18]fluoro-D-glucose {2-[F-18]FDG} and Ga-18-labeled [1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid]-I-Nal3-octreotide {[Ga-68]Ga- DOTA-NOC} PET/computed tomography (CT) from whom 74 and 30 lesions were segmented, respectively. Three reconstructions were performed: data-driven gating-based motion correction (DDGMC), external vital signal module- based motion correction (VSMMC), and noncorrection reconstruction. The standardized uptake values (SUVs) and the volume of the spheres and the lesions were measured and compared among the 3 reconstruction groups. The image noise in the liver was measured, and the visual image quality of motion artifacts was scored by radiologists in the patient study. Results: In the phantom study, the spheres' SUVs increased by 26-36%, and the volumes decreased by 35-38% in DDGMC and VSMMC compared with the noncorrection group. In the 2-[F-18]FDG PET patient study, the lesions' SUVs had a median increase of 10.87-12.65% while the volumes had a median decrease of 14.88-15.18% in DDGMC and VSMMC compared with those of noncorrection. In the [Ga-68]Ga-DOTA-NOC PET patient study, the lesions' SUVs increased by 14.23-15.45%, and the volumes decreased by 19.11-20.94% in DDGMC and VSMMC. The image noise in the liver was equal between the DDGMC, VSMMC, and noncorrection groups. Radiologists found improved image quality in more than 45% of the cases in DDGMC and VSMMC compared with the noncorrection group. There was no statistically significant difference in SUVs, volumes, or visual image quality scores between DDGMC and VSMMC. Conclusions: MCIR improves tumor quantification accuracy and visual image quality by reducing respiratory motion artifacts without compromised image noise performance or elongated acquisition time in 2-[F-18]FDG and [Ga-68]Ga-DOTA-NOC PET/CT tumor imaging. The performance of DDG-driven MCIR is as good as that of the external device-driven solution.
引用
收藏
页码:370 / 383
页数:14
相关论文
共 50 条
  • [31] [68Ga]Ga-FAPI versus 2-[18F]FDG PET/CT in patients with autoimmune thyroiditis: a case control study
    Pabst, Kim M.
    Kessler, Lukas
    Ferdinandus, Justin
    Hamacher, Rainer
    Bartel, Timo
    Siveke, Jens T.
    Nader, Michael
    Brandenburg, Tim
    Desaulniers, Melanie
    Herrmann, Ken
    Fendler, Wolfgang P.
    EJNMMI RESEARCH, 2024, 14 (01):
  • [32] Imaging of multiple brown tumors both in FDG (18F) and 68Ga DOTA-TATE PET/CT studies
    Asa, S.
    Yilmaz, S.
    Kaya, R.
    Sager, S.
    Halac, M.
    Kabasakal, L.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2013, 32 (06): : 404 - 405
  • [33] [68Ga]Ga-DOTA-FAPI-04 and [18F] FDG PET/CT for the diagnosis of primary and metastatic lesions in patients with hepatic cancer
    Jieling Zheng
    Shaobo Yao
    European Journal of Nuclear Medicine and Molecular Imaging, 2020, 47 : 2078 - 2079
  • [34] [68Ga]Ga-DOTA-FAPI-04 and [18F] FDG PET/CT for the diagnosis of primary and metastatic lesions in patients with hepatic cancer
    Zheng, Jieling
    Yao, Shaobo
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (09) : 2078 - 2079
  • [35] Functional imaging in neuroendocrine tumors: Assessment of molecular heterogeneity using [68Ga]Ga-DOTA-TOC and [18F]FDG PET/CT
    Seoane, Z. Nogareda
    Araujo, M. C. Mallon
    Cubes, A. Calatayud
    Corral, C. Barberan
    Novoa, Y. Dominguez
    Castinteira, A. Cousillas
    Lago, N. Martinez
    Leralta, J. M. de Matias
    Nunez, V. Pubul
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2024, 43 (03):
  • [36] A head-to-head comparison of [68Ga]Ga-DOTA-FGFR1 and [18F]FDG PET/CT in the diagnosis of lung cancer
    Yuan, Huiqing
    Chen, Xiaoshan
    Zhao, Xinming
    Dai, Meng
    Liu, Yunuan
    Han, Jingya
    Jing, Fenglian
    Chen, Xiaolin
    Pang, Xiao
    Zhang, Zhaoqi
    Zhang, Jingmian
    Wang, Jianfang
    Wang, Mengjiao
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2025, 52 (03) : 979 - 992
  • [37] Head-to-head comparison of [68Ga]Ga-DOTA.SA.FAPi with [18F]F-FDG PET/CT in patients with breast cancer
    Yadav, Madhav
    Ballal, Sanjana
    Roesch, Frank
    Martin, Marcel
    Moon, Euy Sung
    Raju, Shobhana
    Sheokand, Parvind
    Wakade, Nicky
    Tripathi, Madhavi
    Bal, Chandrasekhar
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [38] Head-to-head evaluation of [18F]FDG PET/CT and [68Ga]Ga-HX01 PET/MR in sarcoma patients
    Zhang, Xiao
    Gai, Yongkang
    Ye, Ting
    Fan, Li
    Xiu, Linfeng
    Ruan, Weiwei
    Hu, Fan
    Chen, Jing
    Lan, Xiaoli
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2025,
  • [39] A Head-to-Head Comparison of [68Ga]Ga-FAPI-04 PET/ CT and 2-[18F]FDG PET/CT in Patients with Idiopathic Pulmonary Fibrosis
    Wang, J.
    Wang, R.
    Peng, X.
    Xiang, J.
    Zhu, Z.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S106 - S106
  • [40] Accurate preoperative staging with [68Ga]Ga-FAPI PET/CT for patients with oral squamous cell carcinoma: a comparison to 2-[18F]FDG PET/CT
    Shaoming Chen
    Zhenying Chen
    Gengsen Zou
    Shan Zheng
    Ke Zheng
    Jiaying Zhang
    Chao Huang
    Shaobo Yao
    Weibing Miao
    European Radiology, 2022, 32 : 6070 - 6079