Evaluation of Robotic Ankle-Foot Orthosis with Different Actuators Using Simscape Multibody for Foot-Drop Patients

被引:1
|
作者
Govindaraj, Gowrishankar [1 ]
Selvakumar, Arockia [1 ]
Doss, Arockia [1 ]
机构
[1] Vellore Inst Technol, Sch Mech Engn, Chennai, Tamil Nadu, India
关键词
robotic ankle-foot orthosis; dynamic motion; spring-based SEA; scissor actuator; dorsiflexion and plantar flexion motion; DESIGN;
D O I
10.3991/ijoe.v19i10.40375
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Gait cycle plays a major role in human locomotion. Patients with neuromuscular problems are unable to walk normally. Foot drop causes difficulty in lifting the front part of the foot and affects the dorsiflexion (DF) and plantar flexion (PF) motion of the foot. Patient with foot drop must use ankle braces to achieve a normal gait. The existing ankle-foot orthosis (AFO) has its own limitations, as it does not produce adequate PF motion. To overcome this scenario, a study was conducted to analyse the two-degrees-of-freedom (DOF) motion of a robotic ankle foot orthosis (RAFO) with a spring-based series elastic actuator (SEA) and scissor actuator. The objective of this paper is to evaluate the two DOF of RAFO with two different actuators using simscape mul-tibody. The RAFO with actuators were designed using Solidworks, and simulation was carried out using simscape multibody, to analyse the 2-DOF motion. The dynamic motion analysis was carried out using block libraries, bodies, joints, constraints, revolute joints, sensors and a pro-portional integral (PI) controller. From the simulation results, the total range of motion (ROM) 40 & DEG; (PF angle of -25 & DEG; and DF angle of 15 & DEG;) is achieved by the proposed RAFO with different actuators. Further, based on the results, the input power consumption of spring-based SEA was found to be less than the scissor actuator. Similarly, torque and output power generation of the scissor actuator was found to be greater than spring-based SEA to achieve the normal human ROM. Hence, the designer can choose a hybrid actuator for foot-drop-disorder applications.
引用
收藏
页码:156 / 168
页数:13
相关论文
共 50 条
  • [21] Robotic Ankle-Foot orthosis With a Variable Viscosity Link Using MR Fluid
    Oba, Takahiro
    Kadone, Hideki
    Hassan, Modar
    Suzuki, Kenji
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2019, 24 (02) : 495 - 504
  • [22] Experimental Evaluation of a Portable Powered Ankle-Foot Orthosis
    Shorter, Kenneth A.
    Li, Yifan
    Morris, Emily A.
    Kogler, Geza F.
    Hsiao-Wecksler, Elizabeth T.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 624 - 627
  • [23] Modelling of human walking to optimise the function of ankle-foot orthosis in Guillan-Barre patients with drop foot
    Jamshidi, N.
    Rostami, M.
    Najarian, S.
    Menhaj, M. B.
    Saadatnia, M.
    Firooz, S.
    SINGAPORE MEDICAL JOURNAL, 2009, 50 (04) : 412 - 417
  • [24] Design and Control of a Low-Cost EMG-Based Soft Robotic Ankle-Foot Orthosis for Foot Drop Rehabilitation
    Gudapati, Nitish
    Kumaran, Koushik
    Deepak, S., V
    Kanna, R. Mukesh
    Jinesh, R.
    Poddar, Himadri
    MACHINES, MECHANISM AND ROBOTICS, INACOMM 2019, 2022, : 1367 - 1382
  • [25] Development of Ankle-Foot Orthosis Using Servo Motor with On-Off Control System for Drop-Foot
    Ubaidillah
    Utomo, Bagus Pribadi
    Wulansari, Pipit
    Parahita, Aristya Naziiha
    Smaradhana, Dharu Feby
    Son, Lovely
    INTERNATIONAL JOURNAL OF AUTOMOTIVE AND MECHANICAL ENGINEERING, 2023, 20 (04) : 10931 - 10942
  • [26] Ankle-foot orthosis with an oil damper versus nonarticulated ankle-foot orthosis in the gait of patients with subacute stroke: a randomized controlled trial
    Yamamoto, Sumiko
    Motojima, Naoyuki
    Kobayashi, Yosuke
    Osada, Yuji
    Tanaka, Souji
    Daryabor, Aliyeh
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2022, 19 (01)
  • [27] A ROBOTIC ANKLE-FOOT ORTHOSIS FOR DAILY-LIFE ASSISTANCE AND REHABILITATION
    Haque, Md Rejwanul
    Zheng, Hao
    Thapa, Saroj
    Kogler, Geza
    Shen, Xiangrong
    PROCEEDINGS OF THE ASME 11TH ANNUAL DYNAMIC SYSTEMS AND CONTROL CONFERENCE, 2018, VOL 1, 2018,
  • [28] Effects of an ankle-foot orthosis on balance performance in patients with hemiparesis of different durations
    Wang, RY
    Yen, LL
    Lee, CC
    Lin, PY
    Wang, MF
    Yang, YR
    CLINICAL REHABILITATION, 2005, 19 (01) : 37 - 44
  • [29] Effect of ankle-foot orthosis on active ankle moment in patients with hemiparesis
    Miyazaki, S
    Yamamoto, S
    Kubota, T
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (04) : 381 - 385
  • [30] Preliminary Design and Engineering Evaluation of a Hydraulic Ankle-Foot Orthosis
    Neubauer, Brett
    Durfee, William
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2016, 10 (04): : 1 - 9