Dosimetric evaluation in brachytherapy and teletherapy for prostate cancer using Monte Carlo simulation and anatomically realistic virtual anthropomorphic phantom

被引:0
|
作者
Santos, William S. [1 ,2 ]
Xavier, Douglas A. A. [2 ]
Santos, Carla J. [2 ]
Neves, Lucio P. [1 ,2 ]
Belinato, Walmir [3 ]
Valenca, Jaoa V. B. [4 ]
Perini, Ana P. [1 ,2 ]
机构
[1] Fed Univ Uberlandia INFIS UFU, Phys Inst, Uberlandia, MG, Brazil
[2] Univ Fed Uberlandia, Elect Engn Fac, Grad Program Biomed Engn PPGEB UFU, Uberlandia, MG, Brazil
[3] Fed Inst Bahia IFBA, Vitoria Da Conquista, BA, Brazil
[4] Fed Univ Hlth Sci Porto Alegre UFCSPA, Porto Alegre, RS, Brazil
关键词
Radiotherapy; 192Ir; 3D-CRT; 4-Fields; Dosimetry; Monte Carlo simulation; Virtual anthropomorphic phantom; HIGH-DOSE-RATE; PROTON RADIOTHERAPY; ENERGY-SPECTRA; RADIATION; PHOTON; NEUTRON; THERAPY; IMRT; IMPACT; BREAST;
D O I
10.1016/j.radphyschem.2023.111000
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The benefits that radiotherapy provides to the patient are unquestionable. However, there is growing concern about the increased risk of radiation-induced secondary cancer and the late damage to organs and tissues associated with the treatment. In this sense, the main objective of this study was to determine the radiation doses in the organs and tissues of the prostate cancer patient for two radiotherapy options, using the Monte Carlo code MCNPx2.7.0. The patient was represented by the ICRP 110 reference virtual anthropomorphic phantom and underwent brachytherapy with a192Ir source, Nucletron Microselectron V2 model, and alternatively, conventional 3D-CRT radiotherapy with an 18 MV X-ray beam from a Varian 2100c medical linear accelerator with 4-field planning (anteroposterior, 0 degrees; posteroanterior, 180 degrees; left lateral, 90 degrees; and right lateral, 270 degrees). A set of conversion factors (CF) for equivalent and effective dose were determined. The obtained results showed that in the more distant organs related to the prostate, such as the lung, brain, and salivary glands, the contribution of scattered radiation decreases, especially when brachytherapy is used. Comparing the two treatment modalities, the CF for effective dose per therapeutic dose was 42% lower when 192Ir was chosen as the main form of treatment. The CF values for photon equivalent doses calculated in 3D-CRT 4-fields are among one and two orders of magnitude higher than 192Ir therapy. These differences are even higher when the neutron equivalent dose in 3D-CRT is considered. In this way, the tools and methodology presented significantly improve the previously used to accurately estimate the equivalent doses in organs and tissues, which is the best quantity to assess the risk of inducing secondary cancer of healthy organs and tissues of patients undergoing treatment with radiotherapy.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Evaluation of the medical and occupational shielding in cerebral angiography using Monte Carlo simulations and virtual anthropomorphic phantoms
    Santos, William S.
    Neves, Lucio P.
    Perini, Ana P.
    Caldas, Linda V. E.
    Maia, Ana F.
    RADIATION PHYSICS AND CHEMISTRY, 2015, 117 : 83 - 87
  • [22] Study of the IsoAid ADVANTAGE™ 125I brachytherapy source dosimetric parameters using Monte Carlo simulation
    Sadeghi, Mahdi
    Hosseini, S. Hamed
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (01) : 211 - 213
  • [23] Evaluation of the Dose Calculation in a Commercial Planning System for a Breast Cancer Brachytherapy Technology Using Monte Carlo Simulation
    Graf, M.
    Cervino, L.
    Scanderbeg, D.
    Yashar, C.
    Jiang, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3612 - 3612
  • [24] Dosimetric Comparison of Radiation Therapy and Proton Therapy in Prostate Cancer Using the Monte Carlo Simulation Platform GEANT4
    Ismail Ghazi
    Zineb Sobhy
    Mustapha Krim
    Othmane Kaanouch
    Meriem Tantaoui
    Abdelkrim Kartouni
    Jamal Inchaouh
    Hamid Chakir
    Said Ouaskit
    Moscow University Physics Bulletin, 2021, 76 : 326 - 332
  • [25] Dosimetric Comparison of Radiation Therapy and Proton Therapy in Prostate Cancer Using the Monte Carlo Simulation Platform GEANT4
    Ghazi, Ismail
    Sobhy, Zineb
    Krim, Mustapha
    Kaanouch, Othmane
    Tantaoui, Meriem
    Kartouni, Abdelkrim
    Inchaouh, Jamal
    Chakir, Hamid
    Ouaskit, Said
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2021, 76 (05) : 326 - 332
  • [26] Dosimetric and energy deposition evaluation of the dual-microcavity capsule structure for glioma 125I brachytherapy using Monte Carlo simulation
    Li, Dongjie
    Liang, Yu
    Yao, Gang
    Guan, Zhongbao
    Gao, Weida
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (07)
  • [27] Dose Analysis at Palladium-103 Brachytherapy of Prostate Cancer Using Monte Carlo Method
    Setiawati, Evi
    Oktajianto, Hammam
    Umiyati, Ngurah Ayu Ketut
    ADVANCED SCIENCE LETTERS, 2017, 23 (07) : 6589 - 6592
  • [28] Dosimetric Analysis of Rhizophora-based Phantom Material in Radiation Therapy Applications Using Monte Carlo GATE Simulation
    Zuber, Siti Hajar
    Hadi, Muhammad Fahmi Rizal Abdul
    Samson, Damilola Oluwafemi
    Jayamani, Jayapramila
    Rabaiee, Nor Ain
    Aziz, Mohd Zahri Abdul
    Hashikin, Nurul Ab. Aziz
    Ying, Chee Keat
    Yusof, Mohd Fahmi Mohd
    Hashim, Rokiah
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (04) : 358 - 364
  • [29] A comparison of the dosimetric parameters of Cs-137 brachytherapy source in different tissues with water using monte carlo simulation
    Sina, Sedigheh
    Faghihi, Reza
    Meigooni, Ali Soleymani
    Iranian Journal of Medical Physics, 2012, 9 (1 A): : 65 - 74
  • [30] Evaluation of the Analytical Anisotropic Algorithm in a Small Finger Joint Phantom Using Monte Carlo Simulation
    Chow, J.
    Owrangi, A.
    Jiang, R.
    MEDICAL PHYSICS, 2014, 41 (06) : 262 - 262