A meta-analysis on the role of sonication in the diagnosis of cardiac implantable electronic device-related infections

被引:0
|
作者
Araujo, Daniela [1 ]
Martins, Joao P. [1 ,2 ,3 ]
Ferreira, Stephanie Lopes [1 ,4 ]
Mota, Sandra [1 ,5 ]
Ferreira, Pedro L. [3 ,6 ]
Pimenta, Rui [1 ,3 ]
机构
[1] Inst Politecn Porto, Escola Super Saude, Rua Dr Antonio Bernardino Almeida, Porto, Portugal
[2] Univ Lisbon, Fac Ciencias, CEAUL Ctr Estat & Aplicacoes, Lisbon, Portugal
[3] CHUdSA Ctr Hosp Univ Santo Antonio, Porto, Portugal
[4] Inst Politecn Porto, REQUIMTE, LAQV, Escola Super Saude, Rua Dr Antonio Bernardino Almeida, Porto, Portugal
[5] Univ Coimbra, Fac Econ, Coimbra, Portugal
[6] Univ Coimbra, Ctr Hlth Studies & Res, Ctr Innovat Biomed & Biotechnol, Ave Dias Silva, Coimbra, Portugal
关键词
sonication; implant associated infections; cardiac implantable electronic devices; biofilms; microbiological diagnosis; systematic review; meta-analysis; MICROBIOLOGICAL DIAGNOSIS; COLONIZATION; CULTURES; BURDEN;
D O I
10.3389/fmicb.2024.1361626
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Introduction One of the biggest obstacles in diagnosing Implant-Associated Infections is the lack of infection criteria and standardized diagnostic methods. These infections present a wide range of symptoms, and their diagnosis can be hampered by the formation of microbial biofilms on the surface of implants. This study aimed to provide insight into the performance of sonication in the diagnosis of infections associated with Cardiac Implantable Electronic Devices, to help define a consensus on the algorithm for the microbial diagnosis of these infections. Methods We carried out a systematic review with meta-analysis. The PRISMA methodology guidelines were followed, and an advanced search was carried out in PubMed and Web of Science, which enabled 8 articles to be included in the review, in which a meta-analysis was also carried out. QUADAS-2 was used to assess the risk of bias and effect measures were calculated to assess publication bias. Results The overall sensitivity of the method was 0.823 (95% CI: 0.682-0.910) and the specificity was 0.632 (95% CI: 0.506-0.743). Discussion These results suggest that sonication may offer advantages in diagnosing these infections. However, it is essential to approach these findings carefully and take into account the recommendations provided in the EHRA 2019 guidelines. This study highlights the importance of more effective diagnostic approaches for implantable medical device-associated infections to improve the quality of treatment and minimize the risks associated with these challenging medical conditions.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Tricuspid valve surgery in implantable cardiac electronic device-related endocarditis: Repair or replace?
    Cakici, Mehmet
    Ozcinar, Evren
    Baran, Cagdas
    Gumus, Fatih
    Durdu, Mustafa Serkan
    Inan, Mustafa Bahadir
    Eryilmaz, Sadik
    Akar, Ahmet Ruchan
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 26 (02): : 183 - 191
  • [32] Microbiological diagnosis of device-related biofilm infections
    Xu, Yijuan
    Larsen, Lone Heimann
    Lorenzen, Jan
    Hall-Stoodley, Luanne
    Kikhney, Judith
    Moter, Annette
    Thomsen, Trine Rolighed
    APMIS, 2017, 125 (04) : 289 - 303
  • [33] Outcomes of complete removal versus conservative therapy in cardiac implantable electronic device infections - A systematic review and Meta-analysis
    Caldonazo, Tulio
    Fischer, Johannes
    Spagnolo, Alena
    Dell'Aquila, Michele
    Kirov, Hristo
    Tasoudis, Panagiotis
    Treml, Ricardo E.
    Vervoort, Dominique
    Sa, Michel Pompeu
    Doenst, Torsten
    Diab, Mahmoud
    Hagel, Stefan
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2024, 411
  • [34] Microbiology of cardiac implantable electronic device infections
    Bongiorni, Maria Grazia
    Tascini, Carlo
    Tagliaferri, Enrico
    Di Cori, Andrea
    Soldati, Ezio
    Leonildi, Alessandro
    Zucchelli, Giulio
    Ciullo, Ilaria
    Menichetti, Francesco
    EUROPACE, 2012, 14 (09): : 1334 - 1339
  • [35] Role of antibiotic envelopes in preventing cardiac implantable electronic device infection: A meta-analysis of 14 859 procedures
    Asbeutah, Abdul Aziz A.
    JOURNAL OF ARRHYTHMIA, 2020, 36 (02) : 377 - 377
  • [36] Role of antibiotic envelopes in preventing cardiac implantable electronic device infection: A meta-analysis of 14 859 procedures
    Kumar, Ashish
    Doshi, Rajkumar
    Shariff, Mariam
    JOURNAL OF ARRHYTHMIA, 2020, 36 (01) : 176 - 179
  • [37] Preventing cardiac implantable electronic device infections
    Padfield, Gareth J.
    Steinberg, Christian
    Bennett, Matthew T.
    Chakrabarti, Santabhanu
    Deyell, Marc W.
    Bashir, Jamil
    Krahn, Andrew D.
    HEART RHYTHM, 2015, 12 (11) : 2344 - 2356
  • [38] Risk factors for cardiac implantable electronic device infection: a systematic review and meta-analysis
    Polyzos, Konstantinos A.
    Konstantelias, Athanasios A.
    Falagas, Matthew E.
    EUROPACE, 2015, 17 (05): : 767 - 777
  • [39] Role of biofilms in neurosurgical device-related infections
    Braxton, EE
    Ehrlich, GD
    Hall-Stoodley, L
    Stoodley, P
    Veeh, R
    Fux, C
    Hu, FZ
    Quigley, M
    Post, JC
    NEUROSURGICAL REVIEW, 2005, 28 (04) : 249 - 255
  • [40] Outcomes in cardiac implantable electronic device-related infective endocarditis: a systematic review of current literature
    Sanghavi, Ria
    Ravikumar, Nidhruv
    Sarodaya, Varun
    Haq, Mawiyah
    Sherif, Mohamed
    Harky, Amer
    FUTURE CARDIOLOGY, 2022, 18 (11) : 891 - 899