VEP examination with new portable device

被引:3
|
作者
Kuba, Miroslav [1 ]
Kremlacek, Jan [1 ]
Vit, Frantisek [1 ]
Kubova, Zuzana [1 ]
Langrova, Jana [1 ]
Szanyi, Jana [1 ]
Chutna, Marie [1 ]
机构
[1] Charles Univ Prague, Fac Med, Dept Pathophysiol, Electrophysiol Lab, Simkova 870, Hradec Kralove 50003, Czech Republic
关键词
VEP portable device; Pattern-reversal; Motion-onset; Cognitive ERP; VEPpeak; VEP diagnostics; VISUAL-EVOKED-POTENTIALS; MOTION-ONSET VEPS; PATTERN; STIMULUS;
D O I
10.1007/s10633-022-09911-w
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction We developed a new portable device called "VEPpeak" for the examination of visual evoked potentials (VEPs) to extend VEP examination beyond specialized electrophysiological laboratories and to simplify the use of this objective, noninvasive, and low-cost method for diagnostics of visual and central nervous system dysfunctions. Methods VEPpeak consists of a plastic headset with a total weight of 390 g containing four EEG amplifiers, an A/D converter, a control unit, and a visual LED stimulator built in the front, vertically adjustable peak. The device is powered and controlled via USB connection from a standard PC/notebook using custom software for visual stimuli generation and for VEP recording and processing. Up to four electrodes can be placed at any scalp location or in combination with two dry electrodes incorporated into the headset. External visual stimulators, such as a tablet, can be used with synchronization. Feasibility and validation studies were conducted with 86 healthy subjects and 76 neuro-ophthalmological patients including 67 who were during the same session also tested with a conventional VEP system. Results VEPpeak recordings to standard (pattern-reversal) and non-standard (motion-onset, red-green alternation) were robust and repeatable and obtained also in immobilized patients. Good comparability of results was achieved between VEPpeak and standard examination. Some systematic differences in peak latencies and amplitudes are consistent with differences in stimulus characteristics of the two compared systems. Discussion VEPpeak provides an inexpensive system for clinical use requiring portability. In addition to ISCEV standard VEP protocols, free choice of stimuli and bio-signal recordings make the device universal for many electrophysiological purposes.
引用
收藏
页码:79 / 91
页数:13
相关论文
共 50 条
  • [21] A NEW, PORTABLE ELECTRONIC DEVICE FOR THE EARLY DIAGNOSIS OF MASTITIS
    FACSAR, I
    BAN, I
    MAGYAR ALLATORVOSOK LAPJA, 1992, 47 (08) : 418 - 422
  • [22] Monitoring the effects of heparin: evaluation of a new portable device
    Cavanagh, SP
    Haine, L
    Ammori, B
    Tate, G
    Braithwaite, P
    Gough, MJ
    Homer-Vanniasinkam, S
    CARDIOVASCULAR SURGERY, 1998, 6 (05): : 496 - 499
  • [23] Development of portable breast self-examination device using enhanced tactile feedback
    Ryu, J.
    Heo, M. S.
    Kim, H. C.
    ELECTRONICS LETTERS, 2010, 46 (25) : 1651 - 1652
  • [24] Training Program for Cardiology Residents to Perform Focused Cardiac Ultrasound Examination with Portable Device
    Siqueira, Vicente N.
    Mancuso, Frederico J. N.
    Campos, Orlando
    De Paola, Angelo A.
    Carvalho, Antonio C.
    Moises, Valdir A.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (10): : 1455 - 1462
  • [25] New device for the examination of stereoscopic negatives.
    Chcron, A
    COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES, 1913, 157 : 42 - 44
  • [26] A New Device for Urinalysis in the Routine Health Examination
    Scott, Harry A.
    RESEARCH QUARTERLY, 1936, 7 (03): : 58 - 74
  • [27] A new device for the entoptic examination of retinal circulation
    Fortin, EP
    COMPTES RENDUS DES SEANCES DE LA SOCIETE DE BIOLOGIE ET DE SES FILIALES, 1907, 62 : 355 - 356
  • [28] A NEW DEVICE FOR THE PHOTOELECTRIC EXAMINATION OF AN AERIAL IMAGE
    SHACK, RV
    WASHER, FE
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1952, 42 (11) : 874 - 874
  • [29] A New Portable Test System for Surge Protective Device (SPD)
    Long Chao
    Zhou Wen-jun
    Wang Lei
    Lao Si-jia
    Yu Jian-hui
    Qiu Ling
    Yi Xiao
    2010 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY & TECHNICAL EXHIBITION ON EMC RF/MICROWAVE MEASUREMENTS & INSTRUMENTATION, 2010, : 1554 - 1557
  • [30] Recent Progress in New Portable Device for Tongue Image Analysis
    Cao Meiling
    Cai Yiheng
    Liu Changjiang
    Shen Lansun
    2008 INTERNATIONAL CONFERENCE ON NEURAL NETWORKS AND SIGNAL PROCESSING, VOLS 1 AND 2, 2007, : 488 - 492