Simultaneous detection of Lead and Cadmium using a composite of Zeolite Imidazole Framework and Reduced Graphene Oxide (ZIF-67/rGO) via electrochemical approach

被引:6
|
作者
Garg, Naini [1 ,2 ]
Deep, Akash [1 ,2 ]
Sharma, Amit L. [1 ,2 ]
机构
[1] CSIR Cent Sci Instruments Org, Sector 30-C, Chandigarh 160030, India
[2] Acad Sci & Innovat Res AcSIR, Ghaziabad 201002, India
关键词
Electrochemical; Heavy metals; Metal-organic framework; Sensor; Specificity; METAL-ORGANIC FRAMEWORKS; HEAVY-METALS; NANOMATERIALS; SENSOR; CROPS; PB2+;
D O I
10.4491/eer.2022.269
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Present work reports the application of a composite of ZIF-67/rGO for the simultaneous detection of traces of lead and cadmium via square wave anodic stripping voltammetry (SWASV) technique. For this, graffoil sheets were modified with synthesized composite for the electrode fabrication [(ZIF-67/rGO)/Graffoil] for its use in sensing studies. The SWASV response of (ZIF-67/rGO)/Graffoil electrode was optimized against deposition potential (-1.0 V) and time (350 s), required for the accumulation of metal ions onto the sensor electrode. The performance of the sensing electrode was then evaluated for lead (Pb2+) and cadmium (Cd2+) ions at various concentrations. The sensor displayed linear response in a wide concentration range of 5-100 ppb. The peak current of the electrode was found to be shifted towards the higher potential at higher metal ion concentrations. Based on the response measured, the limit of detection (LOD) of the fabricated sensor has been estimated and found to be 5 and 2.93 ppb for Pb2+ and Cd2+ ions, respectively. The results obtained revealed good specificity of the proposed sensor towards Pb2+ and Cd2+ ions in the co-presence of several other ions. In addition, the sensor exhibited good reproducibility with a relative standard deviation (RSD) of similar to 2% for both Pb2+ and Cd2+ ions.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] A miniaturized and flexible cadmium and lead ion detection sensor based on micro-patterned reduced graphene oxide/carbon nanotube/bismuth composite electrodes
    Xuan, Xing
    Park, Jae Y.
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 1220 - 1227
  • [42] Constructing a novel electrochemical sensor for the detection of fenitrothion using rare-earth orthophosphate incorporated reduced graphene oxide composite
    Mariyappan, Vinitha
    Sundaresan, Ruspika
    Chen, Shen-Ming
    Ramachandran, Rasu
    Al-Sehemi, Abdullah G.
    Jeevika, Alagan
    Wu, Wei
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2024, 185 : 726 - 738
  • [43] Preparation of reduced graphite oxide loaded with cobalt(II) and nitrogen co-doped carbon polyhedrons from a metal-organic framework (type ZIF-67), and its application to electrochemical determination of metronidazole
    Chen, Han
    Wu, Xingxing
    Zhao, Rui
    Zheng, Zhou
    Yuan, Qunhui
    Dong, Zhijun
    Gan, Wei
    MICROCHIMICA ACTA, 2019, 186 (09)
  • [44] Preparation of reduced graphite oxide loaded with cobalt(II) and nitrogen co-doped carbon polyhedrons from a metal-organic framework (type ZIF-67), and its application to electrochemical determination of metronidazole
    Han Chen
    Xingxing Wu
    Rui Zhao
    Zhou Zheng
    Qunhui Yuan
    Zhijun Dong
    Wei Gan
    Microchimica Acta, 2019, 186
  • [45] A simple electrochemical sensor for quercetin detection based on cadmium telluride nanoparticle incorporated on boron, sulfur co-doped reduced graphene oxide composite
    Karuppusamy, Naveen
    Mariyappan, Vinitha
    Chen, Shen-Ming
    Keerthi, Murugan
    Ramachandran, Rasu
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2021, 626
  • [46] Electrochemical sensors for the simultaneous determination of zinc, cadmium and lead using a Nafion/ionic liquid/graphene composite modified screen-printed carbon electrode
    Chaiyo, Sudkate
    Mehmeti, Eda
    Zagar, Kristina
    Siangproh, Weena
    Chailapakul, Orawon
    Kalcher, Kurt
    ANALYTICA CHIMICA ACTA, 2016, 918 : 26 - 34
  • [47] Synthesis of porous 2D layered nickel oxide-reduced graphene oxide (NiO-rGO) hybrid composite for the efficient electrochemical detection of epinephrine in biological fluid
    Ramu, A. G.
    Umar, Ahmad
    Ibrahim, Ahmed A.
    Algadi, Hassan
    Ibrahim, Yousif S. A.
    Wang, Yao
    Hanafiah, Marlia M.
    Shanmugam, P.
    Choi, Dongjin
    ENVIRONMENTAL RESEARCH, 2021, 200
  • [48] Cyclodextrin-reduced graphene oxide hybrid nanosheets for the simultaneous determination of lead(II) and cadmium(II) using square wave anodic stripping voltammetry
    Lv, Meijiao
    Wang, Xianbao
    Li, Jing
    Yang, Xuyu
    Zhang, Chang'an
    Yang, Jia
    Hu, Hao
    ELECTROCHIMICA ACTA, 2013, 108 : 412 - 420
  • [49] Pt-Doped Reduced Graphene Oxide-Porphyrin-CNT Composite-Based Electrochemical Sensor for Simultaneous Detection of Dopamine, Serotonin and Norepinephrine
    Elshafie, Hashim
    Changalasetty, Suresh Babu
    Basha, A. Alavudeen
    Mubarakali, Azath
    Venkatesh, M.
    Parthasarathy, P.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2025, 172 (02)
  • [50] High-Performance ZIF-7@PANI Electrochemical Sensor for Simultaneous Trace Cadmium and Lead Detection in Water Samples: A Box-Behnken Design Optimization Approach
    Guesmi, Sondes
    Ali, Nashwan H.
    Missaoui, Nadhem
    Aloui, Zouhaier
    Mabrouk, Chama
    Martinez, Carlos Castilla
    Echouchene, Fraj
    Barhoumi, Houcine
    Jaffrezic-Renault, Nicole
    Kahri, Hamza
    SENSORS, 2025, 25 (05)