Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode

被引:2
|
作者
Beigmoradi, Fariba [1 ]
Beitollahi, Hadi [2 ]
机构
[1] Grad Univ Adv Technol, Dept Chem, Kerman 7631818356, Iran
[2] Grad Univ Adv Technol, Inst Sci & High Technol & Environm Sci, Environm Dept, POB 76318-18356, Kerman, Iran
关键词
nitrite; MXene/ZnO/Hb nanocomposite; glassy carbon electrode; real sample analysis; modified electrodes; ELECTROCHEMICAL SENSOR; GOLD NANOPARTICLES; PASTE ELECTRODE; GRAPHENE; NITRATE; SAMPLES; ACID;
D O I
10.3103/S1068375524010034
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The current study was conducted to measure the concentrations of nitrite by a glassy carbon electrode modified with MXene/La3+ doped ZnO/hemoglobin (Hb) nanocomposite as a new voltammetric sensor. Chronoamperometry, differential pulse voltammetry, and cyclic voltammetry were employed to characterize the modification of the electrode surface. According to the analytical results, the glassy carbon electrode incorporated with MXene/La3+ doped ZnO/Hb nanocomposite was able to detect the presence of different concentrations of nitrite (0.1-700.0 mu M), with the detection limit of 4.0 x 10(-8) M. The proposed sensor can be proposed as acceptable electrochemical detector of nitrite in real samples.
引用
收藏
页码:15 / 23
页数:9
相关论文
共 50 条
  • [31] Voltammetric determination of niclosamide at a glassy carbon electrode
    Alemu, H
    Wagana, P
    Tseki, PF
    ANALYST, 2002, 127 (01) : 129 - 134
  • [32] VOLTAMMETRIC DETERMINATION OF NEPTUNIUM AT GLASSY CARBON ELECTRODE
    PLOCK, CE
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1968, 18 (03): : 289 - &
  • [33] Voltammetric determination of paracetamol on the glassy carbon electrode
    毕淑云
    王桂芬
    朴元哲
    王大力
    殷晓萍
    延边大学学报(自然科学版), 2000, (02) : 110 - 112
  • [34] Voltammetric determination of oxytetracycline in milk and pharmaceuticals samples using polyurea modified glassy carbon electrode
    Gashu, Mulu
    Aragaw, Belete Asefa
    Tefera, Molla
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2023, 117
  • [35] Voltammetric determination of Cr(VI) using gold nanoparticles-modified glassy carbon electrode
    Wyantuti, Santhy
    Ishmayana, Safri
    Hartati, Yeni Wahyuni
    INTERNATIONAL SYMPOSIUM ON APPLIED CHEMISTRY 2015, 2015, 16 : 15 - 23
  • [36] Voltammetric behavior and determination of isoniazid in pharmaceuticals by using overoxidized polypyrrole glassy carbon modified electrode
    Majidi, MR
    Jouyban, A
    Asadpour-Zeynali, K
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 589 (01) : 32 - 37
  • [37] Voltammetric determination of florfenicol by using poly(3-methylthiophene) modified glassy carbon electrode
    Taskin, Imren
    Gungor, Oznur
    Titretir Duran, Serap
    POLYMER BULLETIN, 2021, 78 (08) : 4721 - 4741
  • [38] Voltammetric determination of florfenicol by using poly(3-methylthiophene) modified glassy carbon electrode
    İmren Taşkın
    Öznur Güngör
    Serap Titretir Duran
    Polymer Bulletin, 2021, 78 : 4721 - 4741
  • [39] Voltammetric determination of adrenaline using a poly(1-methylpyrrole) modified glassy carbon electrode
    Aslanoglu, Mehmet
    Kutluay, Aysegul
    Karabulut, Serpil
    Abbasoglu, Sultan
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2008, 55 (04) : 794 - 800
  • [40] Voltammetric Determination of Caffeine at Pt/Carbon Nanotubes Composite Modified Glassy Carbon Electrode
    Wei, Yingliang
    Zhang, Luping
    Shao, Chen
    Li, Chao
    CHEMIA ANALITYCZNA, 2009, 54 (04): : 607 - 617