A randomized controlled trial comparing three supraglottic airway devices used as a conduit to facilitate tracheal intubation with flexible bronchoscopy

被引:0
|
作者
Laferriere-Langlois, Pascal [1 ,2 ]
Dion, Alexandre [1 ]
Guimond, Eric [1 ]
Nadeau, Fannie [1 ]
Gagnon, Veronique [1 ]
D'Aragon, Frederick [1 ,2 ,3 ]
Sansoucy, Yanick [1 ]
Colas, Marie-Jose [1 ]
机构
[1] Ctr Hosp Univ Sherbrooke CIUSSS Estrie CHUS, Dept Anesthesiol, Fac Med & Hlth Sci, Ctr Integre Univ Sante & Serv Sociaux Estrie, Sherbrooke, PQ, Canada
[2] Ctr Hosp Univ Montreal, Hop Maisonneuve Rosemont, Dept Anesthesiol & Pain Med, Montreal, PQ, Canada
[3] Ctr Rech Clin CHUS, Sherbrooke, PQ, Canada
关键词
airway; bronchoscope-guided intubation; difficult intubation; endotracheal intubation; intubating laryngeal mask airway; laryngeal masks; supraglottic airway; LARYNGEAL MASK AIRWAY; ENDOTRACHEAL INTUBATION; AMBU(R) AURA-I(TM); DIFFICULT AIRWAY; LMA-FASTRACH(TM); MANAGEMENT;
D O I
10.1007/s12630-023-02444-z
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
PurposeOnce difficult ventilation and intubation are declared, guidelines suggest the use of a supraglottic airway (SGA) as a rescue device to ventilate and, if oxygenation is restored, subsequently as an intubation conduit. Nevertheless, few trials have formally studied recent SGA devices in patients. Our objective was to compare the efficacy of three second-generation SGA devices as conduits for bronchoscopy-guided endotracheal intubation.MethodsIn this prospective, single-blinded three-arm randomized controlled trial, patients with an American Society of Anesthesiologists Physical Status of I-III undergoing general anesthesia were randomized to bronchoscopy-guided endotracheal intubation using AuraGain (TM), Air-Q (R) Blocker, or i-gel (R) devices. We excluded patients with contraindications to an SGA or drugs and who were pregnant or had a neck, spine, or respiratory anomaly. The primary outcome was intubation time, measured from SGA circuit disconnection to CO2 measurement. Secondary outcomes included ease, time, and success of SGA insertion; success of intubation on first attempt; overall intubation success; number of attempts to intubate; ease of intubation; and ease of SGA removals.ResultsOne hundred and fifty patients were enrolled from March 2017 to January 2018. Median intubation times were similar across the three groups (Air-Q Blocker, 44 sec; AuraGain, 45 sec; i-gel, 36 sec; P = 0.08). The i-gel was faster to insert (i-gel: 10 sec; Air-Q Blocker, 16 sec; AuraGain, 16 sec; P < 0.001) and easier to insert (Air-Q Blocker vs i-gel, P = 0.001; AuraGain vs i-gel, P = 0.002). Success of SGA insertion, success of intubation, and number of attempts were similar. The Air-Q Blocker was easier to remove than the i-gel (P < 0.001).ConclusionAll three second-generation SGA devices performed similarly regarding intubation. Despite minor benefits of the i-gel, clinicians should select their SGA based on clinical experience.Study registrationClinicalTrials.gov (NCT02975466); registered on 29 November 2016.
引用
收藏
页码:851 / 860
页数:10
相关论文
共 50 条
  • [31] Randomized prospective trial comparing two supraglottic airway devices: I-gel™ and LMA-Supreme™ in paralyzed patients
    Poulin, L-P
    Joly, N.
    Tanoubi, I
    Drolet, P.
    Donati, F.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2014, 31 : 280 - 280
  • [32] Randomized prospective trial comparing two supraglottic airway devices: i-gel™ and LMA-Supreme™ in paralyzed patients
    Joly, Nikola
    Poulin, Louis-Pierre
    Tanoubi, Issam
    Drolet, Pierre
    Donati, Francois
    St-Pierre, Patrick
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2014, 61 (09): : 794 - 800
  • [33] The effects of water lubrication of tracheal tubes on post-intubation airway complications: study protocol for a randomized controlled trial
    Kim, Eugene
    Yang, Seong Mi
    Yoon, So Jeong
    Bahk, Jae-Hyon
    Seo, Jeong-Hwa
    TRIALS, 2016, 17
  • [34] The effects of water lubrication of tracheal tubes on post-intubation airway complications: study protocol for a randomized controlled trial
    Eugene Kim
    Seong Mi Yang
    So Jeong Yoon
    Jae-Hyon Bahk
    Jeong-Hwa Seo
    Trials, 17
  • [35] Impact on pharyngeal pain of three supraglottic devices for short general anesthesia in adults: randomized controlled clinical trial
    L'Hermite, J.
    Zoric, L.
    Bourgaux, C.
    Bouvet, S.
    Vialles, N.
    Boisson, C.
    Ripart, J.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2013, 32 : A400 - A401
  • [36] Effect of supraglottic airway devices versus endotracheal intubation general anesthesia on outcomes in patients undergoing mechanical thrombectomy A prospective randomized clinical trial
    Zhao, Jing
    Zhu, Wenchao
    Qi, Yingying
    Xu, Guangjun
    Liu, Lei
    Liu, Jingjing
    MEDICINE, 2022, 101 (18) : E29074
  • [37] Blind intubation of anaesthetised children with supraglottic airway devices AmbuAura-i and Air-Q cannot be recommended A randomised controlled trial
    Kleine-Brueggeney, Maren
    Nicolet, Anna
    Nabecker, Sabine
    Seiler, Stefan
    Stucki, Franziska
    Greif, Robert
    Theiler, Lorenz
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2015, 32 (09) : 631 - 639
  • [38] Randomized trial of the i-gel supraglottic airway device versus tracheal intubation during out of hospital cardiac arrest (AIRWAYS-2): Patient outcomes at three and six months
    Benger, Jonathan R.
    Lazaroo, Michelle J.
    Clout, Madeleine
    Voss, Sarah
    Black, Sarah
    Brett, Stephen J.
    Kirby, Kim
    Nolan, Jerry P.
    Reeves, Barnaby C.
    Robinson, Maria
    Scott, Lauren J.
    Smartt, Helena
    South, Adrian
    Taylor, Jodi
    Thomas, Matthew
    Wordsworth, Sarah
    Rogers, Chris A.
    RESUSCITATION, 2020, 157 : 74 - 82
  • [39] 1% Versus 2% Lignocaine for Airway Anesthesia in Flexible Bronchoscopy Without Lignocaine Nebulization (LIFE) A Randomized Controlled Trial
    Madan, Karan
    Biswal, Shiba K.
    Mittal, Saurabh
    Hadda, Vijay
    Mohan, Anant
    Khilnani, Gopi C.
    Pandey, Ravindra M.
    Guleria, Randeep
    JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2018, 25 (02) : 103 - 110
  • [40] A randomized trial comparing the Ambu® Aura-i™ with the air-Q™ intubating laryngeal airway as conduits for tracheal intubation in children
    Jagannathan, Narasimhan
    Sohn, Lisa E.
    Sawardekar, Amod
    Gordon, Jason
    Shah, Ravi D.
    Mukherji, Isabella I.
    Roth, Andrew G.
    Suresh, Santhanam
    PEDIATRIC ANESTHESIA, 2012, 22 (12) : 1197 - 1204