Diagnostic performance of F-18 FDG PET or PET/CT for detection of recurrent gastric cancer: a systematic review and meta-analysis

被引:0
|
作者
Choi, Chang In
Park, Jae Kyun
Jeon, Tae Yong
Kim, Dae-Hwan [1 ,2 ]
机构
[1] Pusan Natl Univ, Pusan Natl Univ Hosp, Coll Med, Dept Surg, 179 Gudeok Ro, Busan 49241, South Korea
[2] Pusan Natl Univ, Pusan Natl Univ Hosp, Coll Med, Biomed Res Inst, 179 Gudeok Ro, Busan 49241, South Korea
来源
关键词
Diagnostic imaging; Fluorodeoxyglucose F18; Positron emission tomography computed tomography; Recurrence; Stomach neoplasms; TEST ACCURACY; FOLLOW-UP; TOMOGRAPHY; CT; SURVEILLANCE; RESECTION; TUMOR; BIAS;
D O I
10.12701/jyms.2023.00220
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This systematic review and meta-analysis investigated the diagnostic performance of F-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) or PET/computed tomography (PET/CT) for the detection of disease recurrence after curative resection of gastric cancer. Methods: The PubMed and Embase databases, from the earliest available date of indexing through November 30, 2019, were searched for studies evaluating the diagnostic performance of F-18 FDG PET or PET/CT to detect recurrent disease after gastric cancer surgery. Results: Across 17 studies (1,732 patients), the pooled sensitivity for F-18 FDG PET or PET/CT was 0.82 (95% confidence interval [CI], 0.74-0.88) with heterogeneity of I-2= 76.5 (p< 0.001), and the specificity was 0.86 (95% CI, 0.78-0.91) with heterogeneity of I-2= 94.2 (p< 0.001). Likelihood ratio (LR) tests gave an overall positive LR of 6.0 (95% CI, 3.6-9.7) and negative LR of 0.2 (95% CI, 0.14-0.31). The pooled diagnostic odds ratio was 29 (95% CI, 13-63). The summary receiver operating characteristic curve indicates that the area under the curve was 0.91 (95% CI, 0.88-0.93). Conclusion: The current meta-analysis showed good sensitivity and specificity of F-18 FDG PET or PET/CT for detecting recurrent disease after curative resection of gastric cancer despite heterogeneity in ethnicity, recurrence rate, histology, and interpretation method.
引用
收藏
页码:S37 / S46
页数:10
相关论文
共 50 条
  • [21] Diagnostic performance of F-18 FDG PET/CT in differentiating autoimmune pancreatitis from pancreatic cancer: a systemic review and meta-analysis
    Datta, Deepanksha
    Selvakumar, B.
    Goel, Akhil Dhanesh
    Chhibber, Sanskriti
    Varshney, Vaibhav Kumar
    Kumar, Rajesh
    ANNALS OF NUCLEAR MEDICINE, 2024, 38 (08) : 619 - 629
  • [22] Diagnostic efficacy of 18F-FDG-PET or PET/CT in breast cancer with suspected recurrence: a systematic review and meta-analysis
    Xiao, Yu
    Wang, Ling
    Jiang, Xuehua
    She, Wei
    He, Li
    Hu, Gang
    NUCLEAR MEDICINE COMMUNICATIONS, 2016, 37 (11) : 1180 - 1188
  • [23] Performance of [18F]FDG PET/CT versus FAPI PET/CT for lung cancer assessment: a systematic review and meta-analysis
    Yang, Qiuya
    Huang, Delong
    Wu, Junhao
    Zhong, Haoshu
    Han, YuanHang
    Jiang, Haodong
    Chen, Yue
    Chen, Gong
    Zhan, Xiang
    Zhou, Ping
    EUROPEAN RADIOLOGY, 2024, 34 (02) : 1077 - 1085
  • [24] Performance of [18F]FDG PET/CT versus FAPI PET/CT for lung cancer assessment: a systematic review and meta-analysis
    Qiuya Yang
    Delong Huang
    Junhao Wu
    Haoshu Zhong
    YuanHang Han
    Haodong Jiang
    Yue Chen
    Gong Chen
    Xiang Zhan
    Ping Zhou
    European Radiology, 2024, 34 : 1077 - 1085
  • [25] Diagnostic accuracy of F-18 FDG PET or PET/CT for detection of lymph node metastasis in clinically node negative head and neck cancer patients; A systematic review and meta-analysis
    Kim, Seong-Jang
    Pak, Kyoungjune
    Kim, Keunyoung
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2019, 40 (02) : 297 - 305
  • [26] Diagnostic performance of F-18 FDG PET/CT in the detection of bone marrow involvement in paediatric hodgkin lymphoma: A meta-analysis
    Kim, Keunyoung
    Kim, Seong-Jang
    LEUKEMIA RESEARCH, 2021, 102
  • [27] Diagnostic Performance of 18F-FDG PET or PET/CT for Detection of Post-Transplant Lymphoproliferative Disorder: A Systematic Review and a Bivariate Meta-Analysis
    Ballova, Veronika
    Muoio, Barbara
    Albano, Domenico
    Bertagna, Francesco
    Canziani, Luca
    Ghielmini, Michele
    Ceriani, Luca
    Treglia, Giorgio
    DIAGNOSTICS, 2020, 10 (02)
  • [28] The diagnostic performance of [18F]FET PET/MRI versus [18F]FDG PET/MRI for recurrent glioma: a systematic review and meta-analysis
    Huo, Huasong
    Shen, Shurui
    Zhang, Lanyue
    Yang, Fuwei
    Li, Yunqian
    CLINICAL AND TRANSLATIONAL IMAGING, 2023, 11 (03) : 285 - 295
  • [29] The diagnostic performance of [18F]FET PET/MRI versus [18F]FDG PET/MRI for recurrent glioma: a systematic review and meta-analysis
    Huasong Huo
    Shurui Shen
    Lanyue Zhang
    Fuwei Yang
    Yunqian Li
    Clinical and Translational Imaging, 2023, 11 : 285 - 295
  • [30] Diagnostic accuracy of 18F-FDG PET or PET/CT for the characterization of adrenal masses: a systematic review and meta-analysis
    Kim, Seong-Jang
    Lee, Sang-Woo
    Pak, Kyoungjune
    Kim, In-Ju
    Kim, Keunyoung
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1086):