Development of revised ResNet-50 for diabetic retinopathy detection

被引:21
|
作者
Lin, Chun-Ling [1 ]
Wu, Kun-Chi [1 ]
机构
[1] Ming Chi Univ Technol, Dept Elect Engn, 84 Gongzhuan Rd, New Taipei City 243, Taiwan
关键词
Diabetic retinopathy (DR); Deep learning; Xception; Alexey; VggNet-; VggNet-16; ResNet-50; CONVOLUTIONAL NEURAL-NETWORKS;
D O I
10.1186/s12859-023-05293-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
BackgroundDiabetic retinopathy (DR) produces bleeding, exudation, and new blood vessel formation conditions. DR can damage the retinal blood vessels and cause vision loss or even blindness. If DR is detected early, ophthalmologists can use lasers to create tiny burns around the retinal tears to inhibit bleeding and prevent the formation of new blood vessels, in order to prevent deterioration of the disease. The rapid improvement of deep learning has made image recognition an effective technology; it can avoid misjudgments caused by different doctors' evaluations and help doctors to predict the condition quickly. The aim of this paper is to adopt visualization and preprocessing in the ResNet-50 model to improve module calibration, to enable the model to predict DR accurately.ResultsThis study compared the performance of the proposed method with other common CNNs models (Xception, AlexNet, VggNet-s, VggNet-16 and ResNet-50). In examining said models, the results alluded to an over-fitting phenomenon, and the outcome of the work demonstrates that the performance of the revised ResNet-50 (Train accuracy: 0.8395 and Test accuracy: 0.7432) is better than other common CNNs (that is, the revised structure of ResNet-50 could avoid the overfitting problem, decease the loss value, and reduce the fluctuation problem).ConclusionsThis study proposed two approaches to designing the DR grading system: a standard operation procedure (SOP) for preprocessing the fundus image, and a revised structure of ResNet-50, including an adaptive learning rating to adjust the weight of layers, regularization and change the structure of ResNet-50, which was selected for its suitable features. It is worth noting that the purpose of this study was not to design the most accurate DR screening network, but to demonstrate the effect of the SOP of DR and the visualization of the revised ResNet-50 model. The results provided an insight to revise the structure of CNNs using the visualization tool.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Fault Detection Method Based on Improved Faster R-CNN: Take ResNet-50 as an Example
    Xie Renjun
    Yuan Junliang
    Wu Yi
    Shu Mengcheng
    GEOFLUIDS, 2022, 2022
  • [32] Evaluation of Enhanced Resnet-50 Based Deep Learning Classifier for Tomato Leaf Disease Detection and Classification
    Upadhyay, Laxmi
    Saxena, Akash
    JOURNAL OF ELECTRICAL SYSTEMS, 2024, 20 (03) : 2270 - 2282
  • [33] Hybrid-RViT: Hybridizing ResNet-50 and Vision Transformer for Enhanced Alzheimer's disease detection
    Yan, Hongjie
    Mubonanyikuzo, Vivens
    Komolafe, Temitope Emmanuel
    Zhou, Liang
    Wu, Tao
    Wang, Nizhuan
    PLOS ONE, 2025, 20 (02):
  • [34] Prostate Image Classification Using Pretrained Models: GoogLeNet and ResNet-50
    Jusman, Yessi
    Nurkholid, Muhammad Ahdan Fawwaz
    Utomo, Feriandri
    2021 15TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND COMMUNICATION SYSTEMS (ICSPCS), 2021,
  • [35] RESNET-50 with ontological visual features based medicinal plants classification
    Renukaradhya, Sapna
    Narayanappa, Sheshappa Shagathur
    Raja, Pravinth
    NETWORK-COMPUTATION IN NEURAL SYSTEMS, 2025,
  • [36] Effective Classification of Colon Cancer using Resnet-50 in Comparison with Squeezenet
    Vasu, K.
    Kumar, Prem S.
    JOURNAL OF PHARMACEUTICAL NEGATIVE RESULTS, 2022, 13 : 1422 - 1429
  • [37] A transfer convolutional neural network for fault diagnosis based on ResNet-50
    Long Wen
    Xinyu Li
    Liang Gao
    Neural Computing and Applications, 2020, 32 : 6111 - 6124
  • [38] 基于Resnet-50的猫狗图像识别
    徐奕哲
    电子制作, 2019, (16) : 44 - 45+55
  • [39] Binary Classification of Laryngeal Images Utilising ResNet-50 CNN Architecture
    Srivastava, Rakesh
    Kumar, Nitish
    Sandhan, Tushar
    INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2025, 77 (02) : 644 - 651
  • [40] Gaussian Blur Masked ResNet2.0 Architecture for Diabetic Retinopathy Detection
    Boruah, Swagata
    Dehloo, Archit
    Gupta, Prajul
    Prusty, Manas Ranjan
    Balasundaram, A.
    CMC-COMPUTERS MATERIALS & CONTINUA, 2023, 75 (01): : 927 - 942