Performance investigation of solar energy-aided compression-based building air conditioning strategies for variable climatic regions

被引:5
|
作者
Singh, Gaurav [1 ]
Das, Ranjan [1 ]
机构
[1] Indian Inst Technol Ropar, Dept Mech Engn, Ropar 140001, Punjab, India
关键词
Desiccant cooling; DX cooling coil; Indirect evaporative cooler; Sensible heat recovery wheel; Compression system; COOLING SYSTEM; DESICCANT;
D O I
10.1007/s11356-024-32273-6
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Decoupling cooling and ventilation tasks with an existing air conditioning methodology are a promising performance-enhancement technology. In this direction, different configurations of a desiccant-integrated independent ventilation element attached to a conventional cooling system are proposed in this study. This work establishes a quantitative comparative performance analysis among the different process air cooling (obtained through desiccant dehumidification) techniques for three different climates, namely, hot-dry, tropical, and Mediterranean. EnergyPlus simulations have been executed on a small-scale office building of 400-m2 area. The building constructional details and other required simulation input parameters follow benchmark standards. As the chemical dehumidification increases, the process air, i.e., supply air temperature that cannot be sent directly to the room, needs to be cooled. Three approaches for process air cooling have been considered: direct expansion (DX) cooling coil, indirect evaporative cooling (IEC), and sensible heat recovery wheel (SHRW). A solar collector assembly with a supporting heating arrangement is coupled with desiccant unit for regeneration. Outdoor air is used for regeneration in the case of the DX cooling coil and IEC, whereas return air is used in the heat recovery wheel case. Annual simulation results reveal that the SHRW-aided case performs superior than DX coil case for the pertinent climatic conditions, with 9.6 to 45.01% of annual energy savings. For the IEC, energy consumption was 1.8 to 18.38% less than that of DX coil. Also, using return air in this best-suited case reduces the net thermal energy requirement for regeneration by 14.63 to 71.65% with respect to DX coil.
引用
收藏
页码:18672 / 18682
页数:11
相关论文
共 31 条
  • [21] Performance optimization of a solar air-conditioning with a three-phase accumulator based on the energy-economic analysis
    Bi, Yuehong
    Lin, Yashan
    Qin, Lifeng
    Wang, Hongyan
    Sun, Ruirui
    JOURNAL OF BUILDING ENGINEERING, 2022, 59
  • [22] Building cooling energy uncertainty and life cycle economic performance: A stochastic air conditioning behavior model based comparative analysis
    Yao, Jian
    JOURNAL OF CLEANER PRODUCTION, 2020, 266
  • [23] Thermodynamic performance analysis of a novel air conditioning system integrating solar absorption compression refrigeration and vacuum membrane-based dehumidification (SACV)
    Liu, Dong
    Yuan, Lunrui
    Chun, Liang
    Gong, Guangcai
    Fang, Xi
    Wang, Hongshun
    Yang, Bing
    Yang, Yahua
    Shang, Yu
    Peng, Pei
    ENERGY AND BUILDINGS, 2023, 288
  • [24] Thermodynamic Performance Investigation of a Small-Scale Solar Compression-Assisted Multi-Ejector Indoor Air Conditioning System for Hot Climate Conditions
    Eveloy, Valerie
    Alkendi, Yusra
    ENERGIES, 2021, 14 (14)
  • [25] Emergy analysis and comprehensive sustainability investigation of a solar-aided liquid air energy storage system based on life cycle assessment
    Ding, Xingqi
    Zhou, Yufei
    Zheng, Nan
    Desideri, Umberto
    Duan, Liqiang
    APPLIED ENERGY, 2024, 365
  • [26] Performance assessment of PCM-based solar energy assisted desiccant air conditioning system combined with a humidification-dehumidification desalination unit
    Wang, Nan
    Wang, Dongxuan
    Dong, Jungang
    Wang, Haitao
    Wang, Renliang
    Shao, Limin
    Zhu, Yiping
    DESALINATION, 2020, 496
  • [27] Performance Study of Small Capacity Solar Autonomous Absorption Air-Conditioning System Coupled with a Low-Energy Residential Building Under Batna (Algeria) Climate
    Ammari, Et-Tahir
    Aksas, Mounir
    Benmachiche, Abdelmoumene H.
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2018, 26 (01)
  • [28] Operation strategy and performance investigation of a high-efficiency multifunctional two-stage vapor compression heat pump air conditioning system for electric vehicles in severe cold regions
    Ning, Qian
    He, Guogeng
    Xiong, Guohui
    Sun, Wei
    Song, Hai
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 48
  • [29] Thermo-hydraulic performance investigation of double pass solar air heater integrated with PCM-based thermal energy storage
    Hedau, Ankush
    Singal, S. K.
    JOURNAL OF ENERGY STORAGE, 2024, 79
  • [30] Performance potentiality analysis of desiccant coated energy exchanger for M-cooler based air conditioning and solar driven drying systems-A case study
    Priyadarshi, Gaurav
    Naik, B. Kiran
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 43