Partial Discharge Ultrasonic Detection Based on Sagnac Optical Interference Technique

被引:2
|
作者
Jiang, Jun [1 ]
He, Yaqian [1 ]
Song, Yu [2 ]
Wang, Ruizhi [1 ]
Li, Xiaohan [3 ]
Ma, Guoming [4 ,5 ]
Wu, Qiang [6 ,7 ]
Liu, Jun [8 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Jiangsu Key Lab New Energy Generat & Power Conver, Nanjing 211106, Jiangsu, Peoples R China
[2] State Grid Huzhou Power Supply Co, Hangzhou 313000, Peoples R China
[3] State Grid Jiangsu Elect Power Co Ltd, Res Inst, Nanjing 211103, Peoples R China
[4] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewabl, Beijing 102206, Peoples R China
[5] North China Elect Power Univ, Beijing Key Lab High Voltage & EMC, Beijing 102206, Peoples R China
[6] Northumbria Univ, Fac Engn & Environm, Newcastle Upon Tyne NE1 8ST, Tyne & Wear, England
[7] Nanchang Hangkong Univ, Key Lab Nondestruct Test, Minist Educ, Nanchang 330063, Jiangxi, Peoples R China
[8] Hangzhou Qianjiang Elect Grp Co Ltd, Hangzhou 311243, Peoples R China
基金
中国博士后科学基金;
关键词
Interference; optical fiber sensor (OFS); partial discharge (PD); polarization state; sensitivity; FIBER SENSOR; LOCALIZATION;
D O I
10.1109/JSEN.2023.3321934
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Partial discharge (PD) ultrasonic detection based on optical interference technique shows practical advantages such as anti-electromagnetic interference, intrinsic safety, and implantability of power equipment, but sensitivity improvement is still a necessity. In this article, the sensitivity is improved by polarization state control and interference structure parameter adjustment. For the disorder of polarization state in the interference system, the detection sensitivity within 20-300 kHz can be improved by 6.48 dB with the help of polarization control. In order to meet the PD detection requirements for various power apparatus, an optical PD detection method based on Sagnac interference structure is proposed. The frequency response can be dynamically adjusted according to the type of PD signals. For the typical PD model in the air, the frequency response of the sensor can be controlled at 20-100 kHz by using a 2000 m delay fiber, and the detection amplitude of the sensor is 5.85 times than that of the conventional piezoelectric transducer (PZT) sensor. For the detection of PD signals in insulating oil, the frequency response can be moved to 20-160 kHz by using a delay fiber with length of 500 m, and the detection amplitude of the sensor is 12.68 times than that of PZT sensor. Therefore, the proposed PD sensor based on the Sagnac interference shows the advantages of adjustable frequency response, multiscenario application, and high detection sensitivity.
引用
收藏
页码:27382 / 27389
页数:8
相关论文
共 50 条
  • [41] Distributed Partial Discharge Locating and Detecting Scheme Based on Optical Fiber Rayleigh Backscattering Light Interference
    Zhou, Zhengxian
    Liu, Hao
    Zhang, Dawei
    Han, Yashuai
    Yang, Xinyan
    Zheng, Xianfeng
    Qu, Jun
    SENSORS, 2023, 23 (04)
  • [42] Research on cable partial discharge detection and location system based on optical fibre timing
    Zhang, Jianjun
    Peng, Fang
    Xie, Anming
    Fei, Yang
    INTERNATIONAL JOURNAL OF COMPUTER APPLICATIONS IN TECHNOLOGY, 2022, 69 (03) : 298 - 307
  • [43] Detection and Propagation Characteristics of Partial Discharge Optical Signal Based on Fluorescent Fiber Sensor
    Meng, Zong
    He, Chaolv
    Liu, Jingbo
    Geng, Jiale
    IEEE SENSORS JOURNAL, 2024, 24 (19) : 30004 - 30013
  • [44] Development of Wireless Partial Discharge Detector based on Ultrasonic Signal
    Zhang Yue
    Fu Zhaoyuan
    Liu Ke
    Lv Xiaoping
    Zhang Guangtao
    Qian Yong
    Yao Weijia
    2019 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2019, : 303 - 306
  • [45] Research on Partial Discharge Detection Technique under Square Wave
    Ding, Yi
    Li, Wenyi
    Wang, Yalin
    Wu, Jiandong
    Yin, Yi
    PROCEEDINGS OF 2020 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM 2020), 2020, : 466 - 469
  • [46] Review on EFPI Fiber-based Ultrasonic Sensors and Its Potentially Partial Discharge Detection Application
    Yao W.
    Si W.
    Lü J.
    Li H.
    Wu X.
    Li X.
    Yu Y.
    Gaodianya Jishu/High Voltage Engineering, 2020, 46 (06): : 1855 - 1866
  • [47] Gold-Diaphragm Based Fabry-Perot Ultrasonic Sensor for Partial Discharge Detection and Localization
    Zhang, Wei
    Lu, Ping
    Ni, Wenjun
    Xiong, Wanze
    Liu, Deming
    Zhang, Jiangshan
    IEEE PHOTONICS JOURNAL, 2020, 12 (03):
  • [48] A high accuracy algorithm for the suppression of narrowband interference in partial discharge detection based on LS-SVM
    Chen, Qun
    He, Jian-Wei
    Chen, Ling-Gen
    Guo, Wen-Chuan
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2009, 37 (22): : 22 - 27
  • [49] Phase Stability Control of Optical Fiber Partial Discharge Ultrasonic Sensing System
    Xing, Chao
    Zang, Qian
    He, Ruidong
    Zhao, Jun
    Wang, Lili
    Dai, Lujian
    Shi, Rongbin
    Wang, Sihan
    Ma, Guoming
    SENSORS, 2022, 22 (21)
  • [50] Partial Discharge Ultrasonic Localization Simulation Based on Double Helix Ultrasonic Sensor Array
    Wang, Bin
    Dong, Ming
    Ren, Ming
    Wu, Zhanyu
    Ma, Ao
    2018 12TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM 2018), 2018, : 136 - 139