Non-invasive measurement of digital plethysmographic variability index to predict fluid responsiveness in mechanically ventilated children: A systematic review and meta-analysis of diagnostic test accuracy studies

被引:6
|
作者
Desgranges, Francois-Pierrick [1 ,11 ]
Bouvet, Lionel [2 ,3 ]
Neto, Edmundo Pereira de Souza [4 ]
Evain, Jean-Noel [5 ,6 ,7 ]
Terrisse, Hugo [4 ,8 ]
Joosten, Alexandre [9 ]
Desebbe, Olivier [10 ]
机构
[1] Villefranche sur Saone Hosp, Hop Nord Ouest, Dept Anaesthesiol, Villefranche Sur Mer, France
[2] Femme Mere Enfant Hosp, Dept Anaesthesiol & Intens Care, Hosp Civils Lyon, Bron, France
[3] Claude Bernard Lyon 1 Univ, Res Unit APCSe VetAgro Sup UPSP 2016 A101, Marcy Letoile, France
[4] Montauban Hosp, Dept Anaesthesiol, Montauban, France
[5] Grenoble Alpes Univ Hosp, Dept Anaesthesiol & Intens Care, Grenoble, France
[6] Grenoble Alpes Univ Hosp, Alps Res Assessment & Simulat Ctr, Grenoble, France
[7] Grenoble Alpes Univ, CNRS 5525, TIMC IMAG Lab, UMR, Grenoble, France
[8] Grenoble Alpes Univ Hosp, Dept Biostat, Grenoble, France
[9] Paris Saclay Univ, Paul Brousse Hosp, AP HP, Dept Anesthesiol & Intens Care, Villejuif, Paris, France
[10] Sauvegarde Clin, Dept Anaesthesiol & Intens Care, Ramsay St, Lyon, France
[11] Hop Nord Ouest, Dept Anaesthesiol, F-69655 Villefranche Sur Mer, France
关键词
Children; Fluid responsiveness; Intraoperative monitoring; Meta-analysis; Plethysmographic variability index; PULSE OXIMETER; MANAGEMENT; HETEROGENEITY; SURGERY; VOLUME;
D O I
10.1016/j.accpm.2023.101194
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: To date, the use of the plethysmographic variability index (PVI) has not been recommended to guide fluid management in the paediatric surgical population. This systematic review and meta-analysis aimed to summarise available evidence about the diagnostic accuracy of digital PVI to predict fluid responsiveness in mechanically ventilated children. Methods: We searched the Pubmed, Embase and Web of Science databases, from inception to January 2022, to identify all relevant studies that investigated the ability of the PVI recorded at the finger to predict fluid responsiveness in mechanically ventilated children. Using a random-effects model, we calculated pooled values of diagnostic odds ratio, sensitivity, and specificity of PVI to predict the response to fluid challenge. Results: Eight studies met the inclusion criteria with a total of 283 patients and 360 fluid challenges. All the studies were carried out in a surgical setting. The area under the summary receiver operating characteristic curve of PVI to predict fluid responsiveness was 0.82. The pooled sensitivity, specificity, and diagnostic odds ratio of PVI for the overall population were 72.4% [95% CI: 65.3-78.7], 65.9% [58.5-72.8], and 9.26 [5.31-16.16], respectively. Conclusion: Our results suggest that digital PVI is a reliable predictor for fluid responsiveness in mechanically ventilated children in the perioperative setting. The diagnostic performance of digital PVI reported in our work for discrimination between responders and non-responders to the fluid challenge was however not as high as previously reported in the adult population. (c) 2023 Societe francaise d'anesthesie et de reanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Diagnostic Accuracy of Liquid Biomarkers for the Non-Invasive Diagnosis of Endometrial Cancer: A Systematic Review and Meta-Analysis
    Karkia, Rebecca
    Wali, Sarah
    Payne, Annette
    Karteris, Emmanouil
    Chatterjee, Jayanta
    CANCERS, 2022, 14 (19)
  • [22] Diagnostic accuracy of transvaginal ultrasound for non-invasive diagnosis of bowel endometriosis: systematic review and meta-analysis
    Hudelist, G.
    English, J.
    Thomas, A. E.
    Tinelli, A.
    Singer, C. F.
    Keckstein, J.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2011, 37 (03) : 257 - 263
  • [23] Accuracy of Continuous Non-Invasive Hemoglobin Monitoring: A Systematic Review and Meta-Analysis
    Cannesson, Maxime
    ANESTHESIA AND ANALGESIA, 2014, 119
  • [24] Umbrella review and multivariate meta-analysis of diagnostic test accuracy studies on hybrid non-invasive imaging for coronary artery disease
    Giuseppe Biondi-Zoccai
    Francesco Versaci
    Ami E. Iskandrian
    Orazio Schillaci
    Alessandro Nudi
    Giacomo Frati
    Francesco Nudi
    Journal of Nuclear Cardiology, 2020, 27 : 1744 - 1755
  • [25] Non-invasive and minimally invasive glucose monitoring devices: a systematic review and meta-analysis on diagnostic accuracy of hypoglycaemia detection
    Nicole Lindner
    Aya Kuwabara
    Tim Holt
    Systematic Reviews, 10
  • [26] Non-invasive and minimally invasive glucose monitoring devices: a systematic review and meta-analysis on diagnostic accuracy of hypoglycaemia detection
    Lindner, Nicole
    Kuwabara, Aya
    Holt, Tim
    SYSTEMATIC REVIEWS, 2021, 10 (01)
  • [27] Umbrella review and multivariate meta-analysis of diagnostic test accuracy studies on hybrid non-invasive imaging for coronary artery disease
    Biondi-Zoccai, Giuseppe
    Versaci, Francesco
    Iskandrian, Ami E.
    Schillaci, Orazio
    Nudi, Alessandro
    Frati, Giacomo
    Nudi, Francesco
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (05) : 1744 - 1755
  • [28] Diagnostic Accuracy of Non-Invasive Diagnostic Tests for Nonalcoholic Fatty Liver Disease: A Systematic Review and Network Meta-Analysis
    Sun, Yuxin
    Hu, Die
    Yu, Mingkun
    Liang, Shi-Bing
    Zheng, Youyou
    Wang, Xin
    Tong, Guangdong
    CLINICAL EPIDEMIOLOGY, 2025, 17 : 53 - 71
  • [29] Tidal Volume and Mortality in Mechanically Ventilated Children: A Systematic Review and Meta-Analysis of Observational Studies
    de Jager, Pauline
    Burgerhof, Johannes G. M.
    van Heerde, Marc
    Albers, Marcel J. I. J.
    Markhorst, Dick G.
    Kneyber, Martin C. J.
    CRITICAL CARE MEDICINE, 2014, 42 (12) : 2461 - 2472
  • [30] Respiratory variation in peripheral arterial blood flow peak velocity to predict fluid responsiveness in mechanically ventilated patients: a systematic review and meta-analysis
    Yao, Bo
    Liu, Jian-yu
    Sun, Yun-bo
    BMC ANESTHESIOLOGY, 2018, 18