Diagnostic Value of the Optic Nerve Sheath in the Diagnosis of Increased Intracranial Pressure in Traumatic Brain Patients

被引:1
|
作者
Ziaei, Maryam [1 ]
Moodi, Soudabeh [1 ]
Pourafzali, Seyed Mehdi [2 ]
Abdolrazaghnejad, Ali [1 ,3 ]
机构
[1] Zahedan Univ Med Sci, Khatam Al Anbia Hosp, Dept Emergency Med, Zahedan, Iran
[2] Shahrekord Univ Med Sci, Sch Med, Dept Emergency Med, Shahrekord, Iran
[3] Zahedan Univ Med Sci, Res Inst Cellular & Mol Sci Infect Dis, Infect Dis & Trop Med Res Ctr, Zahedan, Iran
来源
ADVANCED BIOMEDICAL RESEARCH | 2023年 / 12卷 / 01期
关键词
Brain trauma; intracranial pressure; optic nerve; DIAMETER; INJURY;
D O I
10.4103/abr.abr_248_22
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Increased intracranial pressure (ICP) is a modifiable secondary injury that is associated with poor outcomes in patients with traumatic brain injuries (TBIs). Therefore, the present study was conducted with the aim of determining the ICP of TBI patients by measuring the thickness of the optic nerve sheath diameter (ONSD). Materials and Methods: The present cross-sectional study was conducted on 220 patients with severe TBI that referred to Khatam-al-Anbya Hospital in Zahedan in 2021. The measurement of ONSD was performed by ultrasonography. Results: The results of this study revealed that 22.7% of TBI patients had high ICP. The mean of right and left ONSD in patients with normal ICP was 3.85 +/- 0.83 and 3.85 +/- 0.82 mm, respectively, and was significantly lower than that of patients with abnormal ICP (high ICP) with the mean of 3.85 +/- 0.82 and 6.12 +/- 0.84 mm, respectively (P value <.001). In addition, the right ONSD with the cutoff point of 5.13 mm, the sensitivity of 84%, and the specificity of 95.29% and the left ONSD with the cutoff point of 5.24 mm, the sensitivity of 90%, and the specificity of 95.88% had a significant diagnostic value in the diagnosis of high ICP (P value <.05). Conclusion: The findings of the present study indicated that the measurement of ONSD is a cost-effective and minimally invasive procedure with a higher accuracy in diagnosing high ICP in TBI patients.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] ASSOCIATION BETWEEN OPTIC NERVE SHEATH DIAMETER ON COMPUTED TOMOGRAPHY AND INTRACRANIAL PRESSURE IN PATIENTS WITH SEVERE TRAUMATIC BRAIN INJURY
    Sekhon, M. S.
    Griesdale, D. E.
    Robba, C.
    Needham, E.
    Walland, K.
    McGlashan, N.
    Mossallum, R.
    Menon, D. K.
    INTENSIVE CARE MEDICINE, 2014, 40 : S19 - S19
  • [22] Diagnostic and prognostic value of the optic nerve sheath diameter with respect to the intracranial pressure and neurological outcome of patients following hemicraniectomy
    Gao, Yuzhi
    Li, Qiang
    Wu, Chunshuang
    Liu, Shaoyun
    Zhang, Mao
    BMC NEUROLOGY, 2018, 18
  • [23] Diagnostic and prognostic value of the optic nerve sheath diameter with respect to the intracranial pressure and neurological outcome of patients following hemicraniectomy
    Yuzhi Gao
    Qiang Li
    Chunshuang Wu
    Shaoyun Liu
    Mao Zhang
    BMC Neurology, 18
  • [24] Optic nerve sheath diameter on computed tomography is correlated with simultaneously measured intracranial pressure in patients with severe traumatic brain injury
    Mypinder S. Sekhon
    Donald E. Griesdale
    Chiara Robba
    Nick McGlashan
    Edward Needham
    Katherine Walland
    Alyssa C. Shook
    Peter Smielewski
    Marek Czosnyka
    Arun K. Gupta
    David K. Menon
    Intensive Care Medicine, 2014, 40 : 1267 - 1274
  • [25] Optic nerve sheath diameter on computed tomography is correlated with simultaneously measured intracranial pressure in patients with severe traumatic brain injury
    Sekhon, Mypinder S.
    Griesdale, Donald E.
    Robba, Chiara
    McGlashan, Nick
    Needham, Edward
    Walland, Katherine
    Shook, Alyssa C.
    Smielewski, Peter
    Czosnyka, Marek
    Gupta, Arun K.
    Menon, David K.
    INTENSIVE CARE MEDICINE, 2014, 40 (09) : 1267 - 1274
  • [26] Optic nerve sheath diameter and intracranial pressure
    Dubourg, Julie
    Javouhey, Etienne
    Messerer, Mahmoud
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2012, 9 (05) : 570 - 571
  • [27] Predictive Value of Optic Nerve Sheath Diameter for Diagnosis of Intracranial Hypertension in Children With Severe Brain Injury
    Cour-Andlauer, Fleur
    Portefaix, Aurelie
    Wroblewski, Isabelle
    Rabilloud, Muriel
    Bordet, Fabienne
    Cogniat, Berengere
    Didier, Capucine
    Pouyau, Robin
    Valla, Frederic V.
    Kassai-Koupai, Behrouz
    Simeon, Gaelle
    Ginhoux, Tiphanie
    Courtil-Teyssedre, Sonia
    Javouhey, Etienne
    FRONTIERS IN PEDIATRICS, 2022, 10
  • [28] OPTIC NERVE SHEATH DIAMETER TO EVALUATE INCREASED INTRACRANIAL PRESSURE IN HEPATIC ENCEPHALOPATHY
    McLaughlin, Diane
    CRITICAL CARE MEDICINE, 2019, 47
  • [29] Using Optic Nerve Sheath Diameter for Intracranial Pressure (ICP) Monitoring in Traumatic Brain Injury: A Scoping Review
    Martinez-Palacios, Karol
    Vasquez-Garcia, Sebastian
    Fariyike, Olubunmi A.
    Robba, Chiara
    Rubiano, Andres M.
    NEUROCRITICAL CARE, 2023, 40 (3) : 1193 - 1212
  • [30] Optic nerve sheath diameter by ultrasound is a good screening tool for high intracranial pressure in traumatic brain injury
    Ashraf S. Altayar
    Amr Z. Abouelela
    Eslam E. Abdelshafey
    Khaled S. S. Mohammed
    Ahmed A. Hassan
    Mohammed A. Khattab
    Walid Alhabashy
    Wael Gomaa
    Amr F. Mohammed
    Muhammad S. Umerani
    Irish Journal of Medical Science (1971 -), 2021, 190 : 387 - 393