A green liquid chromatography-tandem mass spectrometry method for the simultaneous analysis of volatile thiols and their precursors in oenological samples

被引:6
|
作者
Muhl, Jennifer R. [1 ]
Derycke, Mathilde [1 ,2 ]
Pilkington, Lisa I. [1 ]
Fedrizzi, Bruno [1 ]
Deed, Rebecca C. [1 ,3 ,4 ,5 ]
机构
[1] Univ Auckland Waipapa Taumata Rau, Sch Chem Sci, Auckland, New Zealand
[2] Ecole Natl Super Chim Mulhouse, Mulhouse, France
[3] Univ Auckland Waipapa Taumata Rau, Sch Biol Sci, Auckland, New Zealand
[4] Univ Auckland Waipapa Taumata Rau, Sch Chem Sci, Private Bag 92019, Auckland, New Zealand
[5] Univ Auckland Waipapa Taumata Rau, Sch Biol Sci, Private Bag 92019, Auckland, New Zealand
关键词
Green analytical chemistry; LC-MS/MS; QuEChERS; 3-sulfanylhexan-1-ol; 3-sulfanylhexan-1-ol precursors; SOLID-PHASE EXTRACTION; ANALYTICAL-CHEMISTRY; ETHYL-PROPIOLATE; VARIETAL THIOLS; DERIVATIZATION; 3-MERCAPTOHEXAN-1-OL; WINE; REAGENT;
D O I
10.1016/j.chroma.2023.464273
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Improvements to the quantification of three white wine impact odorants 3-sulfanylhexan-1-ol, 3-sulfanylhexyl acetate, and 4-sulfanyl-4-methylpentan-2-one, and the non-volatile precursors from which they are released during fermentation, is of great interest to the wine science community. Recent reports of a "Quick, Easy, Cheap, Effective, Rugged and Safe" (QuEChERS) based method for the concurrent analysis of these thiols and their precursors via liquid chromatography tandem mass spectrometry (LC-MS/MS) has enabled the development of far simpler methods, as well as aligning these analyses with principles of green analytical chemistry. This current work reports the development and validation of a QuEChERS based LC-MS/MS method utilising a safer derivatising agent, 4,4 & PRIME;-dithiodipyridine, while greatly minimising the reagents involved and waste produced. We demonstrate that this new method compares favourably to the previously reported method with repeatability of 0.2-1.3%RSD and 0.4-5.2%RSD for precursors and free thiols. Further, the commercially available internal standard, 1-hexanethiol, used in previous analytical methods was compared to stable isotope labelled analogues of the analytes, with results suggesting that it may not be a reliable internal standard.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Simultaneous Determination of 5 Peptide Antibiotics in Bovine Milk Samples by Liquid Chromatography-Tandem Mass Spectrometry
    Liu Jia-Jia
    Jin Fen
    She Yong-Xin
    Liu Hong-Bin
    Shi Xiao-Mei
    Wang Miao
    Wang Jing
    Xu Si-Yuan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (05) : 652 - 657
  • [32] Simultaneous Determination of 25 Ergot Alkaloids in Cereal Samples by Ultraperformance Liquid Chromatography-Tandem Mass Spectrometry
    Guo, Qiaozhen
    Shao, Bing
    Du, Zhenxia
    Zhang, Jing
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2016, 64 (37) : 7033 - 7039
  • [33] Simultaneous determination of fourteen steroid hormone residues in beef samples by liquid chromatography-tandem mass spectrometry
    Zhao, Chaomin
    Yue, Zhenfeng
    Wu, Hui
    Lai, Furao
    ANALYTICAL METHODS, 2014, 6 (19) : 8030 - 8038
  • [34] Characterization of liquid chromatography-tandem mass spectrometry method for the determination of acrylamide in complex environmental samples
    Patrick D. DeArmond
    Amanda L. DiGoregorio
    Analytical and Bioanalytical Chemistry, 2013, 405 : 4159 - 4166
  • [35] Characterization of liquid chromatography-tandem mass spectrometry method for the determination of acrylamide in complex environmental samples
    DeArmond, Patrick D.
    DiGoregorio, Amanda L.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (12) : 4159 - 4166
  • [36] Simultaneous analysis of Alternaria toxins and citrinin in tomato: an optimised method using liquid chromatography-tandem mass spectrometry
    Tolgyesi, Adam
    Stroka, Joerg
    Tamosiunas, Vytautas
    Zwickel, Theresa
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2015, 32 (09): : 1512 - 1522
  • [37] Simultaneous analysis of allopurinol and oxypurinol using a validated liquid chromatography-tandem mass spectrometry method in human plasma
    Rathod, Dhiraj M.
    Patel, Keyur R.
    Mistri, Hiren N.
    Jangid, Arvind G.
    Shrivastav, Pranav S.
    Sanyal, Mallika
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2017, 7 (01) : 56 - 62
  • [38] Analytical method for multimycotoxins in roasted coffee samples using liquid chromatography-tandem mass spectrometry
    Choi, B.
    Kim, J. H.
    Lee, K. S.
    Kim, C., I
    Lee, J. Y.
    Park, H. M.
    INTERNATIONAL FOOD RESEARCH JOURNAL, 2023, 30 (02): : 487 - 496
  • [39] A New Liquid Chromatography-Tandem Mass Spectrometry Method for Determination of Bisoprolol in Human Plasma Samples
    Peste, Gabriela
    Bibire, Nela
    Apostu, Mihai
    Vlase, Aurel
    Oniscu, Corneliu
    JOURNAL OF BIOMEDICINE AND BIOTECHNOLOGY, 2009,
  • [40] Development of a liquid chromatography-tandem mass spectrometry method for simultaneous detection of the main milk allergens
    Ji, Jian
    Zhu, Pei
    Pi, Fuwei
    Sun, Chao
    Sun, Jiadi
    Jia, Min
    Ying, Chen
    Zhang, Yinzhi
    Sun, Xiulan
    FOOD CONTROL, 2017, 74 : 79 - 88