A green liquid chromatography-tandem mass spectrometry method for the simultaneous analysis of volatile thiols and their precursors in oenological samples

被引:6
|
作者
Muhl, Jennifer R. [1 ]
Derycke, Mathilde [1 ,2 ]
Pilkington, Lisa I. [1 ]
Fedrizzi, Bruno [1 ]
Deed, Rebecca C. [1 ,3 ,4 ,5 ]
机构
[1] Univ Auckland Waipapa Taumata Rau, Sch Chem Sci, Auckland, New Zealand
[2] Ecole Natl Super Chim Mulhouse, Mulhouse, France
[3] Univ Auckland Waipapa Taumata Rau, Sch Biol Sci, Auckland, New Zealand
[4] Univ Auckland Waipapa Taumata Rau, Sch Chem Sci, Private Bag 92019, Auckland, New Zealand
[5] Univ Auckland Waipapa Taumata Rau, Sch Biol Sci, Private Bag 92019, Auckland, New Zealand
关键词
Green analytical chemistry; LC-MS/MS; QuEChERS; 3-sulfanylhexan-1-ol; 3-sulfanylhexan-1-ol precursors; SOLID-PHASE EXTRACTION; ANALYTICAL-CHEMISTRY; ETHYL-PROPIOLATE; VARIETAL THIOLS; DERIVATIZATION; 3-MERCAPTOHEXAN-1-OL; WINE; REAGENT;
D O I
10.1016/j.chroma.2023.464273
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Improvements to the quantification of three white wine impact odorants 3-sulfanylhexan-1-ol, 3-sulfanylhexyl acetate, and 4-sulfanyl-4-methylpentan-2-one, and the non-volatile precursors from which they are released during fermentation, is of great interest to the wine science community. Recent reports of a "Quick, Easy, Cheap, Effective, Rugged and Safe" (QuEChERS) based method for the concurrent analysis of these thiols and their precursors via liquid chromatography tandem mass spectrometry (LC-MS/MS) has enabled the development of far simpler methods, as well as aligning these analyses with principles of green analytical chemistry. This current work reports the development and validation of a QuEChERS based LC-MS/MS method utilising a safer derivatising agent, 4,4 & PRIME;-dithiodipyridine, while greatly minimising the reagents involved and waste produced. We demonstrate that this new method compares favourably to the previously reported method with repeatability of 0.2-1.3%RSD and 0.4-5.2%RSD for precursors and free thiols. Further, the commercially available internal standard, 1-hexanethiol, used in previous analytical methods was compared to stable isotope labelled analogues of the analytes, with results suggesting that it may not be a reliable internal standard.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] A single run liquid chromatography-tandem mass spectrometry method for the analysis of varietal thiols and their precursors in wine
    Tonidandel, Loris
    Larcher, Roberto
    Barbero, Alice
    Jelley, Rebecca E.
    Fedrizzi, Bruno
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1658
  • [2] A liquid chromatography-tandem mass spectrometry method for simultaneous analysis of acrylamide and the precursors, asparagine and reducing sugars in bread
    Nielsen, NJ
    Granby, K
    Hedegaard, RV
    Skibsted, LH
    ANALYTICA CHIMICA ACTA, 2006, 557 (1-2) : 211 - 220
  • [3] Development of a fast gas chromatography-tandem mass spectrometry method for volatile aromatic compound analysis in oenological products
    Paolini, Mauro
    Tonidandel, Loris
    Moser, Sergio
    Larcher, Roberto
    JOURNAL OF MASS SPECTROMETRY, 2018, 53 (09): : 801 - 810
  • [4] Simultaneous Method for Selected PBDEs and HBCDDs in Foodstuffs Using Gas Chromatography-Tandem Mass Spectrometry and Liquid Chromatography-Tandem Mass Spectrometry
    Lipicar, Eva
    Fras, Danijela
    Javernik, Nino
    Prosen, Helena
    TOXICS, 2023, 11 (01)
  • [5] Simultaneous analysis of antibiotics in biological samples by ultra high performance liquid chromatography-tandem mass spectrometry
    Cazorla-Reyes, Rocio
    Romero-Gonzalez, Roberto
    Garrido Frenich, Antonia
    Rodriguez Maresca, Manuel Angel
    Martinez Vidal, Jose Luis
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 89 : 203 - 212
  • [6] Simultaneous analysis of unregistered pesticides in Korea by liquid chromatography-tandem mass spectrometry
    Lee, Sang-Hyeob
    Hwang, Jeong-In
    Jeon, Sang-Oh
    Kim, Jang-Eok
    Lee, Young
    Kim, Hee-Jung
    Lee, Hyeon-Suk
    Jang, Moon-Ik
    Lee, Gyu-Seek
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 250
  • [7] Development of liquid chromatography-tandem mass spectrometry method for analysis of polyphenolic compounds in liquid samples of grape juice, green tea and coffee
    Sapozhnikova, Yelena
    FOOD CHEMISTRY, 2014, 150 : 87 - 93
  • [8] Simultaneous analysis of kasugamycin and streptomycin in vegetables by liquid chromatography-tandem mass spectrometry
    Alechaga, Elida
    Moyano, Encarnacion
    Teresa Galceran, M.
    ANALYTICAL METHODS, 2015, 7 (08) : 3600 - 3607
  • [9] Analysis of phosphodiestrease inhibitors by liquid chromatography-tandem mass spectrometry method
    Bik, M. Ahmad
    Eryavuz, D.
    Tok, O.
    Sivrikaya, A.
    Abusoglu, S.
    Unlu, A.
    CLINICA CHIMICA ACTA, 2019, 493 : S59 - S59
  • [10] Simultaneous Multiclass Analysis of Cyanotoxins in Cyanobacterial Samples Using Hydrophilic Interaction Liquid Chromatography-Tandem Mass Spectrometry
    Bergin, Rosemary
    Peters, Siobhan
    Mitrovic, Simon
    Bishop, David P.
    JOURNAL OF SEPARATION SCIENCE, 2025, 48 (03)