Experimental assessment of lamella heat exchanger as cold intake air system for spark ignition engine by utilizing vehicle air conditioning system

被引:5
|
作者
Ikhtiar, Usman [1 ]
Hairuddin, Abdul Aziz Bin [1 ]
Bin Asarry, Azizan [1 ]
Rezali, Khairil Anas Bin Md. [1 ]
Ali, Hafiz Muhammad [2 ,3 ]
Jalal, Rifqi Irzuan Abdul [4 ]
机构
[1] Univ Putra Malaysia, Fac Engn, Dept Mech & Mfg Engn, Serdang 43400, Selangor, Malaysia
[2] King Fahd Univ Petr & Minerals, Dept Mech Engn, Dhahran 31261, Saudi Arabia
[3] King Fahd Univ Petr & Minerals, Interdisciplinary Res Ctr Renewable Energy & Power, Dhahran 31261, Saudi Arabia
[4] Univ Kuala Lumpur, Malaysia France Inst, Automot Engn Sect, Bandar Baru Bangi 43650, Selangor, Malaysia
关键词
Lamella heat exchanger (LHE); Vehicle air conditioning (VAC); Engine intake charge air (EICA); Engine intake charge air cooling (EICAC); Intercooler; Intake temperature; Exhaust emissions; Engine power; Torque; And fuel consumption; EJECTOR COOLING SYSTEM; THERMODYNAMIC ANALYSIS; THERMAL MANAGEMENT; JET-EJECTOR; WASTE HEAT; COMBUSTION; PERFORMANCE; TEMPERATURE; EMISSIONS; DRIVEN;
D O I
10.1016/j.icheatmasstransfer.2023.106989
中图分类号
O414.1 [热力学];
学科分类号
摘要
Global warming and air pollution have become major concerns for humanity, especially in the last few decades. The transport sector contributes significantly to a large proportion of urban air pollution due to the dramatic increase in vehicle production and transportation growth, resulting in harmful emissions. Cooling the intake air temperature is one of the alternative strategies to reduce exhaust emissions and improve combustion conditions. The present study adopted the Lamella heat exchanger (LHE) as an intake air cooling device for a 1.5 L naturally aspirated engine. The design size of LHE is based on the maximum space available in the test vehicle for its installation. A refrigerant derived from the vehicle air conditioning (VAC) system acts as a coolant medium for LHE. For experimental testing, two types of vehicle statuses are considered, i.e., moving and static, to evaluate the performance of the cooling device in both positions. Engine power, torque, exhaust emissions, and fuel consumption are designated as evaluating parameters. The results depict that lowering the temperature of the intake air by 30-40 degrees C through LHE reduces the increased quantity of exhaust emissions due to the VAC system by 43.6%, 39.5%, 47.3%, and 64.5% for CO, CO2, HC, and NOx respectively. Further, the amount of lost engine power and torque due to the VAC system is partially recovered by 17% and 24%, respectively, by introducing cold air into the engine. Convincingly, LHE has a significant potential to improve engine performance.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] CONTROLLER FOR VEHICLE AIR-CONDITIONING SYSTEM
    OOI, TH
    LAU, KT
    LIM, CH
    IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 1990, 36 (02) : 66 - 75
  • [42] Experimental study on ammonia/hydrogen/air combustion in spark ignition engine conditions
    Lhuillier, Charles
    Brequigny, Pierre
    Contino, Francesco
    Mounaïm-Rousselle, Christine
    Fuel, 2020, 269
  • [43] Experimental study on ammonia/hydrogen/air combustion in spark ignition engine conditions
    Lhuillier, Charles
    Brequigny, Pierre
    Contino, Francesco
    Mounaim-Rousselle, Christine
    FUEL, 2020, 269
  • [44] Analysis of enthalpy change with/without a heat pipe heat exchanger in a tropical air conditioning system
    Yau, Y. H.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2006, 30 (15) : 1251 - 1263
  • [45] Economic evaluation of cold air conditioning system
    Yang, H
    Li, R
    Xuan, ZY
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 1619 - 1626
  • [46] Experimental investigation of a vertical earth-to-air heat exchanger system
    Liu, Zhengxuan
    Yu, Zhun
    Yang, Tingting
    Li, Shuisheng
    El Mankibi, Mohamed
    Roccamena, Letizia
    Qin, Di
    Zhang, Guoqiang
    ENERGY CONVERSION AND MANAGEMENT, 2019, 183 : 241 - 251
  • [47] Finite time analysis of a geothermal heat engine driven air conditioning system
    Davis, GW
    Wu, C
    ENERGY CONVERSION AND MANAGEMENT, 1997, 38 (03) : 263 - 268
  • [48] Experimental study and analysis of solar based winter air conditioning system using desiccant coated heat exchanger
    Nain, Sunil
    Parinam, Anuradha
    Kajal, Sanjay
    MATERIALS TODAY-PROCEEDINGS, 2021, 46 : 9938 - 9943
  • [49] Experimental investigation of solar driven desiccant air conditioning system based on silica gel coated heat exchanger
    Kumar, Amit
    Yadav, Auadhesh
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 69 : 51 - 63
  • [50] Experimental study on the performance of CO2 residential air-conditioning system with an internal heat exchanger
    Tao, Y. B.
    He, Y. L.
    Tao, W. Q.
    Wu, Z. G.