Design and Validation of a Low-Cost Mobile EEG-Based Brain-Computer Interface

被引:7
|
作者
Craik, Alexander [1 ,2 ]
Gonzalez-Espana, Juan Jose [1 ,2 ]
Alamir, Ayman [2 ,3 ,4 ]
Edquilang, David [5 ]
Wong, Sarah [2 ,5 ]
Rodriguez, Lianne Sanchez [1 ,2 ]
Feng, Jeff [2 ,5 ]
Francisco, Gerard E. [6 ,7 ]
Contreras-Vidal, Jose L. [1 ,2 ]
机构
[1] Univ Houston, Dept Elect & Comp Engn, Houston, TX 77004 USA
[2] Univ Houston, NSF Ind Univ Cooperat Res Ctr Bldg Reliable Adv &, Noninvas Brain Machine Interface Syst Lab, Houston, TX 77004 USA
[3] Univ Houston, Dept Biomed Engn, Houston, TX 77004 USA
[4] Jazan Univ, Dept Elect Engn, Jazan 45142, Saudi Arabia
[5] Univ Houston, Dept Ind Design, Houston, TX 77004 USA
[6] Univ Texas Hlth McGovern, Med Sch, Dept Phys Med & Rehabil, Houston, TX 77030 USA
[7] Mem Hermann Hosp, Inst Rehabil Res TIRR, Houston, TX 77030 USA
基金
美国国家科学基金会;
关键词
brain-computer interfaces; electroencephalography; mobile EEG; rehabilitation; neurodiagnostics; motor intent detection;
D O I
10.3390/s23135930
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Objective: We designed and validated a wireless, low-cost, easy-to-use, mobile, dry-electrode headset for scalp electroencephalography (EEG) recordings for closed-loop brain-computer (BCI) interface and internet-of-things (IoT) applications. Approach: The EEG-based BCI headset was designed from commercial off-the-shelf (COTS) components using a multi-pronged approach that balanced interoperability, cost, portability, usability, form factor, reliability, and closed-loop operation. Main Results: The adjustable headset was designed to accommodate 90% of the population. A patent-pending self-positioning dry electrode bracket allowed for vertical self-positioning while parting the user's hair to ensure contact of the electrode with the scalp. In the current prototype, five EEG electrodes were incorporated in the electrode bracket spanning the sensorimotor cortices bilaterally, and three skin sensors were included to measure eye movement and blinks. An inertial measurement unit (IMU) provides monitoring of head movements. The EEG amplifier operates with 24-bit resolution up to 500 Hz sampling frequency and can communicate with other devices using 802.11 b/g/n WiFi. It has high signal-to-noise ratio (SNR) and common-mode rejection ratio (CMRR) (121 dB and 110 dB, respectively) and low input noise. In closed-loop BCI mode, the system can operate at 40 Hz, including real-time adaptive noise cancellation and 512 MB of processor memory. It supports LabVIEW as a backend coding language and JavaScript (JS), Cascading Style Sheets (CSS), and HyperText Markup Language (HTML) as front-end coding languages and includes training and optimization of support vector machine (SVM) neural classifiers. Extensive bench testing supports the technical specifications and human-subject pilot testing of a closed-loop BCI application to support upper-limb rehabilitation and provides proof-of-concept validation for the device's use at both the clinic and at home. Significance: The usability, interoperability, portability, reliability, and programmability of the proposed wireless closed-loop BCI system provides a low-cost solution for BCI and neurorehabilitation research and IoT applications.
引用
收藏
页数:26
相关论文
共 50 条
  • [31] Towards an EEG-based brain-computer interface for online robot control
    Li, Yantao
    Zhou, Gang
    Graham, Daniel
    Holtzhauer, Andrew
    MULTIMEDIA TOOLS AND APPLICATIONS, 2016, 75 (13) : 7999 - 8017
  • [32] An EEG-Based Brain-Computer Interface for Dual Task Driving Detection
    Lin, Chin-Teng
    Wang, Yu-Kai
    Chen, Shi-An
    NEURAL INFORMATION PROCESSING, PT I, 2011, 7062 : 701 - +
  • [33] Status of deep learning for EEG-based brain-computer interface applications
    Hossain, Khondoker Murad
    Islam, Md. Ariful
    Hossain, Shahera
    Nijholt, Anton
    Ahad, Md Atiqur Rahman
    FRONTIERS IN COMPUTATIONAL NEUROSCIENCE, 2023, 16
  • [34] An improvement of robot arm for EEG-based brain-computer interface system
    Ekawa, Youko
    Nishida, Tomoya
    Yamawaki, Nobuyuki
    NEUROSCIENCE RESEARCH, 2010, 68 : E215 - E216
  • [35] Usefulness of an EEG-based brain-computer interface to establish communication in ALS
    Lahrmann, H
    Neuper, C
    Müller, GR
    Scherer, R
    Pfurtscheller, G
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2005, 238 : S458 - S458
  • [36] Evaluating the Feasibility of Visual Imagery for an EEG-Based Brain-Computer Interface
    Kilmarx, Justin
    Tashev, Ivan
    Millan, Jose del R.
    Sulzer, James
    Lewis-Peacock, Jarrod
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2024, 32 : 2209 - 2219
  • [37] An EEG-Based Brain-Computer Interface Using Spectral Correlation Function
    Panahi, Nazila
    Amirani, Mehdi Chehel
    Valizadeh, Morteza
    IEEE ACCESS, 2023, 11 : 33236 - 33247
  • [38] Enhance Reading Comprehension from EEG-Based Brain-Computer Interface
    Liu, Xinping
    Cao, Zehong
    ADVANCES IN ARTIFICIAL INTELLIGENCE, AI 2023, PT I, 2024, 14471 : 545 - 555
  • [39] Bayesian Learning for Spatial Filtering in an EEG-Based Brain-Computer Interface
    Zhang, Haihong
    Yang, Huijuan
    Guan, Cuntai
    IEEE TRANSACTIONS ON NEURAL NETWORKS AND LEARNING SYSTEMS, 2013, 24 (07) : 1049 - 1060
  • [40] Voice Familiarity Detection using EEG-based Brain-Computer Interface
    Smitha, K. G.
    Vinod, A. P.
    Mahesh, K.
    2016 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2016, : 1626 - 1631