Organics removal from office wastewater in attached growth biological process of a packaged onsite wastewater treatment system

被引:0
|
作者
Ahmed, Mohd Elmuntasir [1 ]
Khajah, M. [1 ]
Abdullah, H. [1 ]
Al-Matouq, A. [1 ]
机构
[1] Kuwait Inst Sci Res, Water Res Ctr, POB 24885, Safat 13109, Kuwait
关键词
In; -situ; Wastewater; Office; Packaged units; Treatment; BED BIOFILM REACTOR; PERFORMANCE;
D O I
10.5004/dwt.2023.29945
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Advancements in onsite wastewater treatment technology have attracted attention since various types of wastewater can be viably treated and reused at production. In the case of wastewater produced by buildings, including offices (including laboratories and workshops), wastewater is dilute and has particular characteristics warranting an investigation of the performance of onsite systems. This paper investigates the performance of an attached growth biological process in a full-scale onsite wastewater treatment system treating office wastewater. The organics removal efficiency of biochemical oxygen demand (BOD) and chemical oxygen demand (COD) of 93.0% and 93.3%, respectively, were achieved, and nutrient removal efficiency was 72.3 +/- 0.7 and 25.9% +/- 0.9% for total nitrogen (TN) and total phosphorous, respectively. The low nutrient concentrations and the presence of inhibitive chemicals such as phenols, metals, and high ammonia concentrations have caused unfavourable conditions for biomass growth, and caused washout (particularly heterotrophs) and reduced efficiency. Due to these factors, organics removal was as low as 5.2% and 4.8% for BOD and COD, respectively, and nutrient removal was as low as 65.4% and 0.0% for TN and TP, respectively. These performance limitations constitute essential guidance for using similar onsite treatment systems.
引用
收藏
页码:78 / 85
页数:8
相关论文
共 50 条
  • [21] TRACE ORGANICS REMOVAL BY ADVANCED WASTEWATER-TREATMENT
    MCCARTY, PL
    REINHARD, M
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1980, 52 (07): : 1907 - 1922
  • [22] Electrocoagulation/Electroflotation Process for Removal of Organics and Microplastics in Laundry Wastewater
    Akarsu, Ceyhun
    Deniz, Fatma
    CLEAN-SOIL AIR WATER, 2021, 49 (01)
  • [23] Generic monitoring system in the biological wastewater treatment process
    Choi, SW
    Yoo, CK
    Lee, KH
    Lee, IB
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2001, 34 (10) : 1218 - 1228
  • [24] Outstanding Potential for Treating Wastewater from Office Buildings Using Fixed Activated Sludge with Attached Growth Process
    Phan, Nguyen Nguyet Minh
    Bui, Quang Chi
    Nguyen, Trung Viet
    Yang, Chih-Chi
    Chen, Ku-Fan
    Tsai, Yung-Pin
    SUSTAINABILITY, 2024, 16 (17)
  • [25] Review on biological wastewater treatment and resources recovery: attached and suspended growth systems
    Machineni, Lakshmi
    WATER SCIENCE AND TECHNOLOGY, 2019, 80 (11) : 2013 - 2026
  • [26] Impact of legacy nitrogen in conventional septic system on nitrogen removal for onsite wastewater treatment
    Shahraki, Zahra Maleki
    Mao, Xinwei
    Waugh, Stuart
    Walker, Harold
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [27] Investigation on thiosulfate-involved organics and nitrogen removal by a sulfur cycle-based biological wastewater treatment process
    Qian, Jin
    Lu, Hui
    Cui, Yanxiang
    Wei, Li
    Liu, Rulong
    Chen, Guang-Hao
    WATER RESEARCH, 2015, 69 : 295 - 306
  • [28] Onsite wastewater differential treatment system: modeling approach
    Zavala, MAL
    Funamizu, N
    Takakuwa, T
    WATER SCIENCE AND TECHNOLOGY, 2002, 46 (6-7) : 317 - 324
  • [29] Optimization of a periodic biological process for nitrogen removal from wastewater
    Potter, TG
    Koopman, B
    Svoronos, SA
    WATER RESEARCH, 1996, 30 (01) : 142 - 152
  • [30] REMOVAL OF ORGANICS FROM WASTEWATER BY REVERSE OSMOSIS - WATR
    DUVEL, WA
    HELFGOTT, T
    GENETELL.EJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1970, (SEP): : 38 - &