Vibration Behavior of Post-Tensioned Concrete Slabs

被引:0
|
作者
Aziz, Fady Ibrahim Ezzat [1 ]
Abdelrahman, Amr [2 ]
Sayed-Ahmed, Ezzeldin Yazeed [3 ]
机构
[1] Ain Shams Univ, Cairo, Egypt
[2] Ain Shams Univ, Dept Concrete Struct, Cairo, Egypt
[3] Amer Univ Cairo, Dept Construct Engn, Cairo, Egypt
关键词
flat slabs; fundamental frequency; peak vertical acceleration; post-tensioned floors; prestressed concrete; static deflection method; vibration; PRESTRESS FORCE; BEAMS;
D O I
10.14359/51738716
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Post-tensioned concrete flat slabs with high span-depth ratios are susceptible to vibration problems. Although the issue was addressed in previous research, there is no final agreement on the effect of prestress level on the fundamental frequency of post-tensioned concrete slabs. Through numerical modeling using Abaqus software, this paper presents the effect of prestressing forces on the fundamental frequencies of slabs. This paper also examines the applicability and accuracy of the available mathematical models to estimate the fundamental frequency of concrete slabs. Finally, the paper presents two newly proposed mathematical models created by a neural designer program. The first model estimates the fundamental frequencies of uncracked concrete slabs, and it is more accurate than the currently available equations. The second proposed model estimates the peak acceleration of uncracked concrete slabs, and it is applicable for the dynamic motion of a forcing frequency of 2 Hz and a damping ratio of 2%.
引用
收藏
页码:15 / 28
页数:14
相关论文
共 50 条
  • [31] POST-TENSIONED CONCRETE FLAT SLABS WITH EDGE COLUMNS SUBMITTED TO PUNCHING SHEAR
    Barban, Vladimir V.
    Melo, Guilherme S.
    FIB SYMPOSIUM PRAGUE 2011: CONCRETE ENGINEERING FOR EXCELLENCE AND EFFICIENCY, VOLS 1 AND 2, 2011, : 163 - 166
  • [32] Post-tensioned hybrid slabs on plastic clay
    Anderson, Robert B.
    Aberdeen's Concrete Construction, 1996, 41 (08): : 619 - 620
  • [33] Fire tests on unbonded post-tensioned one-way concrete slabs
    Bailey, C. G.
    Ellobody, E.
    MAGAZINE OF CONCRETE RESEARCH, 2009, 61 (01) : 67 - 76
  • [34] Contraction Joints for Residential Post-Tensioned Slabs
    Haynes, Harvey
    Bondy, Kenneth B.
    Concrete International, 2020, 42 (07) : 33 - 35
  • [35] Fire Behavior of Two-Way Post-Tensioned Concrete Slabs Provided with Bonded Tendons: An Experimental Study
    Zhang, Li
    Wei, Ya
    Au, Francis Tat Kwong
    Li, Jing
    STRUCTURES IN FIRE, 2016, : 45 - 52
  • [36] Delamination Cracking Behavior of Curved Post-Tensioned Concrete Structures
    Choi, Jongkwon
    Woods, Clint R.
    Hrynyk, Trevor D.
    Bayrak, Oguzhan
    ACI STRUCTURAL JOURNAL, 2020, 117 (03) : 169 - 183
  • [37] Post-tensioned concrete inspection guide
    Aberdeen's Concrete Repair Digest, 1997, 8 (03):
  • [38] The State of Post-Tensioned Concrete Education
    Bondy, Kenneth B.
    Concrete International, 2014, 36 (10) : 32 - 36
  • [39] Durability of post-tensioned concrete bridges
    Randall, W
    Frank, KH
    RECENT DEVELOPMENTS IN BRIDGE ENGINEERING, 2003, : 233 - 242
  • [40] SIMPLIFICATION OF POST-TENSIONED CONCRETE ANCHORAGES
    HUGHES, BP
    MIDDLETO.CI
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS PART 2-RESEARCH AND THEORY, 1974, 57 (JUN): : 373 - 378