Dispersive liquid-liquid microextraction followed by sweeping micellar electrokinetic chromatography-tandem mass spectrometry for determination of six breast cancer drugs in human plasma

被引:7
|
作者
Mlinaric, Zvonimir [1 ]
Turkovic, Lu [1 ]
Sertic, Miranda [1 ]
机构
[1] Univ Zagreb, Fac Pharm & Biochem, Dept Pharmaceut Anal, Zagreb 10000, Croatia
关键词
Micellar electrokinetic chromatography; Mass spectrometry; Dispersive liquid -liquid microextraction; Breast cancer; CDK4/6; inhibitors; Therapeutic drug monitoring; KINASE; 4/6; INHIBITOR; PHASE-I; PALBOCICLIB; RIBOCICLIB; EXTRACTION; SAMPLES;
D O I
10.1016/j.chroma.2024.464698
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Herein, we have developed a novel method of aqueous-sample dispersive liquid-liquid microextraction (AqSDLLME) followed by sweeping micellar electrokinetic chromatography-tandem mass spectrometry (MEKC-MS/ MS) for simultaneous determination of breast cancer drugs letrozole, anastrozole, palbociclib, ribociclib, abemaciclib, and fulvestrant in human plasma. Coupling of MEKC to MS was possible due to the use of ammonium perfluorooctanoate (APFO) as a volatile surfactant. The MEKC and MS conditions were optimized to achieve a fast, sensitive, selective, and green analysis enabling full separation of the analytes within 16 min. Electrophoretic buffer was 125 mM APFO at apparent pH 10.5 in 32 % MeOH, while sheath liquid was 70 % MeOH with 0.2 % formic acid, delivered at 10 mu L/min. Excellent extraction recoveries from plasma ranging from 89.4 to 104.9 % were obtained with a combination of protein precipitation and DLLME. The developed method was validated according to the ICH guidelines. Remarkable selectivity, accuracy (bias < 6.7 %), precision (RSD < 15.8 %), and stability (bias < 10.4 %) with insignificant matrix effect (RSD < 14.0 %) and no carry-over were obtained over a wide range of concentrations. Linearity with inter-day slope RSD lower than 8.7 % was demonstrated. With this method, very low concentrations could be detected after the injection of only 68.7 nL of the sample. The method was applied to plasma samples from six women currently receiving breast cancer treatment. Determined concentrations of the drugs of interest agreed with concentrations found in clinical studies, thus proving the suitability of the developed method for therapeutic drug monitoring as a superior alternative to published LC-MS methods.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] SIMPLE MEASUREMENT OF TESTOSTERONE IN MALE SALIVA SAMPLES USING DISPERSIVE LIQUID-LIQUID MICROEXTRACTION FOLLOWED BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY DETECTION
    Sobhi, Hamid Reza
    Henry, Hugues
    Bruce, Stephen J.
    Esrafili, Ali
    Rochat, Bertrand
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2014, 37 (09) : 1278 - 1286
  • [22] Dispersive Liquid-Liquid Microextraction Combined with Micellar Electrokinetic Chromatography for the Determination of Pesticide in Apple Sample
    Wang, Yanjun
    Fan, Zhefeng
    JOURNAL OF DISPERSION SCIENCE AND TECHNOLOGY, 2014, 35 (09) : 1319 - 1324
  • [23] Determination of Selected Pyrrolizidine Alkaloids in Honey by Dispersive Liquid-Liquid Microextraction and Ultrahigh-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Celano, Rita
    Piccinelli, Anna Lisa
    Campone, Luca
    Russo, Mariateresa
    Rastrelli, Luca
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2019, 67 (31) : 8689 - 8699
  • [24] Determination of selected pyrrolizidine alkaloids in honey by dispersive liquid-liquid microextraction and ultrahigh-performance liquid chromatography-tandem mass spectrometry
    Celano, Rita
    Piccinelli, Anna Lisa
    Campone, Luca
    Russo, Mariateresa
    Rastrelli, Luca
    Journal of Agricultural and Food Chemistry, 2019, 67 (31): : 8689 - 8699
  • [25] A new method for the determination of benzophenone-UV filters in human serum samples by dispersive liquid-liquid microextraction with liquid chromatography-tandem mass spectrometry
    Vela-Soria, F.
    Ballesteros, O.
    Zafra-Gomez, A.
    Ballesteros, L.
    Navalon, A.
    TALANTA, 2014, 121 : 97 - 104
  • [26] Ultrasound assisted extraction and dispersive liquid-liquid microextraction with liquid chromatography-tandem mass spectrometry for determination of alkylphenol levels in cleaning products
    Vinas, Pilar
    Campillo, Natalia
    Pastor-Belda, Marta
    Hernandez-Cordoba, Manuel
    ANALYTICAL METHODS, 2015, 7 (16) : 6718 - 6725
  • [27] Determination of hydroxylated stilbenes in wine by dispersive liquid-liquid microextraction followed by gas chromatography mass spectrometry
    Rodriguez-Cabo, T.
    Rodriguez, I.
    Cela, R.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1258 : 21 - 29
  • [28] Dispersive liquid-liquid microextraction for the determination of new generation pesticides in soils by liquid chromatography and tandem mass spectrometry
    Pastor-Belda, Marta
    Garrido, Isabel
    Campillo, Natalia
    Vinas, Pilar
    Hellin, Pilar
    Flores, Pilar
    Fenoll, Jose
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1394 : 1 - 8
  • [29] Use of dispersive liquid–liquid microextraction for the determination of carbamates in juice samples by sweeping-micellar electrokinetic chromatography
    David Moreno-González
    Laura Gámiz-Gracia
    Ana M. García-Campaña
    Juan M. Bosque-Sendra
    Analytical and Bioanalytical Chemistry, 2011, 400 : 1329 - 1338
  • [30] Sensitive and rapid determination of pyrethroids in human blood by gas chromatography-tandem mass spectrometry with ultrasound-assisted dispersive liquid-liquid microextraction
    Gao, Xue
    Guo, Hao
    Wang, Junwei
    Zhao, Qingbiao
    DRUG TESTING AND ANALYSIS, 2018, 10 (07) : 1131 - 1138