Real-time motion monitoring using orthogonal cine MRI during MR-guided adaptive radiation therapy for abdominal tumors on 1.5T MR-Linac

被引:22
|
作者
Jassar, Hassan [1 ]
Tai, An [1 ]
Chen, Xinfeng [1 ]
Keiper, Timothy D. D. [1 ]
Paulson, Eric [1 ]
Lathuiliere, Fabienne [2 ]
Beriault, Silvain [2 ]
Hebert, Francois [2 ]
Savard, Laurence [2 ]
Cooper, David T. T. [2 ]
Cloake, Sneha [2 ]
Li, X. Allen [1 ]
机构
[1] Med Coll Wisconsin, Dept Radiat Oncol, Milwaukee, WI USA
[2] Elekta AB, Stockholm, Sweden
关键词
abdominal tumor motion; motion monitoring with cine MRI; MR-guided adaptive radiation therapy; COMPUTED-TOMOGRAPHY; PROSTATE LOCALIZATION; RESPIRATORY MOTION; PRECISE SETUP; LIVER-TUMORS; ORGAN MOTION; RADIOTHERAPY; TRACKING; CANCER; LUNG;
D O I
10.1002/mp.16342
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundReal-time motion monitoring (RTMM) is necessary for accurate motion management of intrafraction motions during radiation therapy (RT). PurposeBuilding upon a previous study, this work develops and tests an improved RTMM technique based on real-time orthogonal cine magnetic resonance imaging (MRI) acquired during magnetic resonance-guided adaptive RT (MRgART) for abdominal tumors on MR-Linac. MethodsA motion monitoring research package (MMRP) was developed and tested for RTMM based on template rigid registration between beam-on real-time orthogonal cine MRI and pre-beam daily reference 3D-MRI (baseline). The MRI data acquired under free-breathing during the routine MRgART on a 1.5T MR-Linac for 18 patients with abdominal malignancies of 8 liver, 4 adrenal glands (renal fossa), and 6 pancreas cases were used to evaluate the MMRP package. For each patient, a 3D mid-position image derived from an in-house daily 4D-MRI was used to define a target mask or a surrogate sub-region encompassing the target. Additionally, an exploratory case reviewed for an MRI dataset of a healthy volunteer acquired under both free-breathing and deep inspiration breath-hold (DIBH) was used to test how effectively the RTMM using the MMRP can address through-plane motion (TPM). For all cases, the 2D T2/T1-weighted cine MRIs were captured with a temporal resolution of 200 ms interleaved between coronal and sagittal orientations. Manually delineated contours on the cine frames were used as the ground-truth motion. Common visible vessels and segments of target boundaries in proximity to the target were used as anatomical landmarks for reproducible delineations on both the 3D and the cine MRI images. Standard deviation of the error (SDE) between the ground-truth and the measured target motion from the MMRP package were analyzed to evaluate the RTMM accuracy. The maximum target motion (MTM) was measured on the 4D-MRI for all cases during free-breathing. ResultsThe mean (range) centroid motions for the 13 abdominal tumor cases were 7.69 (4.71-11.15), 1.73 (0.81-3.05), and 2.71 (1.45-3.93) mm with an overall accuracy of <2 mm in the superior-inferior (SI), the left-right (LR), and the anterior-posterior (AP) directions, respectively. The mean (range) of the MTM from the 4D-MRI was 7.38 (2-11) mm in the SI direction, smaller than the monitored motion of centroid, demonstrating the importance of the real-time motion capture. For the remaining patient cases, the ground-truth delineation was challenging under free-breathing due to the target deformation and the large TPM in the AP direction, the implant-induced image artifacts, and/or the suboptimal image plane selection. These cases were evaluated based on visual assessment. For the healthy volunteer, the TPM of the target was significant under free-breathing which degraded the RTMM accuracy. RTMM accuracy of <2 mm was achieved under DIBH, indicating DIBH is an effective method to address large TPM. ConclusionsWe have successfully developed and tested the use of a template-based registration method for an accurate RTMM of abdominal targets during MRgART on a 1.5T MR-Linac without using injected contrast agents or radio-opaque implants. DIBH may be used to effectively reduce or eliminate TPM of abdominal targets during RTMM.
引用
收藏
页码:3103 / 3116
页数:14
相关论文
共 50 条
  • [21] Short-term toxicity outcomes after MR-guided SBRT for (peri-)pancreatic tumors on a 1.5T MR-linac
    Eijkelenkamp, H.
    Grimbergen, G.
    Heerkens, H.
    Meijer, G.
    Daamen, L.
    Molenaar, Q.
    van Santvoort, H.
    Erickson, B.
    Hall, W.
    Intven, M.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S179 - S180
  • [22] Improvement of Real-Time Motion Tracking with Daily Optimized Registration of Cine MRI On MR-Linac
    Keiper, T.
    Tai, A.
    Chen, X.
    Paulson, E.
    Lathuiliere, F.
    Beriault, S.
    Hebert, F.
    Cooper, D.
    Lachaine, M.
    Li, X. Allen
    MEDICAL PHYSICS, 2020, 47 (06) : E627 - E627
  • [23] Inter- and Intrafraction Bladder and Rectum Motion in Patients With Cervical Cancer Under MR-Guided Radiotherapy on a 1.5T MR-Linac
    Ding, S.
    Liu, H.
    Wang, B.
    Li, Y.
    Liu, B.
    Ouyang, Y.
    Huang, X.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E612 - E612
  • [24] A Workflow for Treating Adaptive Pancreatic SBRT on a 1.5T MR-Linac with Abdominal Compression
    Ferris, W. S.
    George, B. N.
    Caster, J. M.
    Plichta, K. A.
    St-Aubin, J. J.
    MEDICAL PHYSICS, 2024, 51 (10) : 7772 - 7772
  • [25] Feasibility of online adaptive MR-guided radiotherapy for rectal cancer on a 1.5T MR-linac.
    Intven, M.
    van Otterloo, S. De Mol
    Mook, S.
    Doornaert, P.
    Tijssen, R.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S403 - S404
  • [26] Clinical outcomes after online adaptive MR-guided stereotactic body radiotherapy for pancreatic tumors on a 1.5 T MR-linac
    Eijkelenkamp, Hidde
    Grimbergen, Guus
    Daamen, Lois A.
    Heerkens, Hanne D.
    van de Ven, Saskia
    Mook, Stella
    Meijer, Gert J.
    Molenaar, Izaak Q.
    van Santvoort, Hjalmar C.
    Paulson, Eric
    Erickson, Beth Ann
    Verkooijen, Helena M.
    Hall, William Adrian
    Intven, Martijn P. W.
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [27] Vas deferens metastasis from prostate adenocarcinoma treated with daily-adaptive MR-guided SBRT on 1.5T MR-linac
    Vitale, Claudio
    Nicosia, Luca
    Pastorello, Edoardo
    Rigo, Michele
    Doraku, Joniada
    Salgarello, Matteo
    Alongi, Filippo
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2022, 27 (02) : 371 - 374
  • [28] Online adaptive MR-guided radiotherapy for rectal cancer; feasibility of the workflow on a 1.5T MR-linac: clinical implementation and initial experience
    Intven, M. P. W.
    van Otterloo, S. R. de Mol
    Mook, S.
    Doornaert, P. A. H.
    de Groot-van Breugel, E. N.
    Sikkes, G. G.
    Willemsen-Bosman, M. E.
    van Zijp, H. M.
    Tijssen, R. H. N.
    RADIOTHERAPY AND ONCOLOGY, 2021, 154 : 172 - 178
  • [29] Outcomes of Tolerability, Acute Toxicity and Quality of Life from MR-Guided Radiation Therapy (1.5T MR-Linac) for Liver Metastases in the MOMENTUM Study
    Westley, R.
    Peltenburg, J.
    Aitken, K. L.
    Awan, M. J.
    Braam, P. M.
    Daamen, L. A.
    Hosni, A.
    Intven, M. P. W.
    Janssen, T.
    Schytte, T.
    Sonke, J. J.
    Straza, M. W., Jr.
    Paulson, E. S.
    Hall, W. A.
    Nowee, M. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E156 - E156
  • [30] Treatment planning for MR-guided SBRT of pancreatic tumors on a 1.5 T MR-Linac: A global consensus protocol
    Grimbergen, Guus
    Eijkelenkamp, Hidde
    Snoeren, Louk M. W.
    Bahij, Rana
    Bernchou, Uffe
    Bijl, Erik van der
    Heerkens, Hanne D.
    Binda, Shawn
    Ng, Sylvia S. W.
    Bouchart, Christelle
    Paquier, Zelda
    Brown, Kerryn
    Khor, Richard
    Chuter, Robert
    Freear, Linnea
    Dunlop, Alex
    Mitchell, Robert Adam
    Erickson, Beth A.
    Hall, William A.
    Scripes, Paola Godoy
    Tyagi, Neelam
    de Leon, Jeremiah
    Tran, Charles
    Oh, Seungjong
    Renz, Paul
    Shessel, Andrea
    Taylor, Edward
    Intven, Martijn P. W.
    Meijer, Gert J.
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2024, 47