Ultrasound shear wave elastography for the evaluation of renal pathological changes in adult patients

被引:7
|
作者
Leong, Sook Sam [1 ]
Jalalonmuhali, Maisarah [2 ]
Nazri, Mohammad
Ng, Kwan Hoong [2 ,4 ]
Vijayananthan, Anushya [5 ]
Hisham, Ranitha [6 ]
Wong, Jeannie Hsiu Ding [3 ]
机构
[1] Univ Teknol MARA, Fac Hlth Sci, Ctr Med Imaging Studies, Selangor, Malaysia
[2] Univ Malaya, Fac Med, Dept Med, Kuala Lumpur, Malaysia
[3] Univ Malaya, Fac Med, Dept Biomed Imaging, Kuala Lumpur, Malaysia
[4] UCSI Univ, Fac Med & Hlth Sci, Port Dickson, Negeri Sembilan, Malaysia
[5] Univ Malaya Specialist Ctr, Dept Biomed Imaging, Kuala Lumpur, Malaysia
[6] Univ Malaya, Univ Malaya Lib, Kuala Lumpur, Malaysia
来源
BRITISH JOURNAL OF RADIOLOGY | 2023年 / 96卷 / 1144期
关键词
FORCE IMPULSE QUANTIFICATION; ALLOGRAFT FIBROSIS; ELASTICITY QUANTIFICATION; TISSUE ELASTICITY; KIDNEY; DISEASE; DIAGNOSIS; STIFFNESS; ARFI;
D O I
10.1259/bjr.20220288
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Many studies have conflicting findings in using shear wave elastography (SWE) to assess renal fibrosis. This study reviews the use of SWE to evaluate pathological changes in native kidneys and renal allo-grafts. It also tries to elucidate the confounding factors and care taken to ensure the results are consistent and reliable. Methods: The review was carried out according to the Preferred Reporting Items for SystematicReviews and Meta-Analysis guidelines. Literature search was conducted in Pubmed, Web of Science and Scopus data-base up to 23 October 2021. To evaluate risk and bias applicability, the Cochrane risk -of bias tool and GRADE was used. The review was registered under PROSPERO CRD42021265303.Results: A total of 2921 articles were identified. 104 full texts were examined and 26 studies included in system-atic review. 11 studies performed on native kidneys and 15 studies on transplanted kidney. A wide range of impact factors was found that affect the accuracy of SWE of renal fibrosis in adult patientsConclusions: Compared to point SWE, two-dimensional SWE with elastogram could enable better selection of the region of interest in kidneys, leading to reproducible results. Tracking waves were attenuated as the depth from skin to region of interest increased, therefore, SWE is not recommended for overweight or obese patients. Variable transducer forces might also affect SWE repro-ducibility, thus, training of operators to ensure consistent operator-dependent transducer forces may be helpful. Advances in knowledge: This review provides a holistic insight on the efficiency of using SWE in evaluating pathological changes in native and transplanted kidneys, thereby contributing to the knowledge of its utilisation in clinical practice.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Magnetic resonance elastography vs. point shear wave ultrasound elastography for the assessment of renal allograft dysfunction
    Kennedy, Paul
    Bane, Octavia
    Hectors, Stefanie J.
    Gordic, Sonja
    Berger, Mark
    Delaney, Veronica
    Salem, Fadi
    Lewis, Sara
    Menon, Madhav
    Taouli, Bachir
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 126
  • [42] Magnetic resonance elastography vs. point shear wave ultrasound elastography for the assessment of renal allograft dysfunction
    Kennedy, Paul
    Bane, Octavia
    Hector, Stefanie J.
    Gordic, Sonja
    Berger, Mark
    Delaney, Veronica
    Salem, Fadi
    Lewis, Sara
    Menon, Madhav
    Taouli, Bachir
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 130
  • [43] Evaluation of normal and pathological Achilles tendon by real-time shear wave elastography
    Petrescu, Pompiliu Horatiu
    Izvernariu, Dragos Andrei
    Iancu, Catalina
    Dinu, Gabriel Ovidiu
    Crisan, Dan
    Popescu, Simona Alina
    Sirli, Roxana Lucia Denisa
    Nistor, Bogdan Mihai
    Rautia, Ion Calin
    Lazureanu, Dorela Codruta
    Dema, Sorin
    Prejbeanu, Ion Radu
    Sporea, Ioan
    ROMANIAN JOURNAL OF MORPHOLOGY AND EMBRYOLOGY, 2016, 57 (02): : 785 - 790
  • [44] Plane wave elastography: a frequency-domain ultrasound shear wave elastography approach
    Khodayi-mehr, Reza
    Urban, Matthew W.
    Zavlanos, Michael M.
    Aquino, Wilkins
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (12):
  • [45] Ultrasound evaluation of stiffness and vascularity of renal parenchymal damage secondary to hydronephrosis in pediatric patients using shear wave elastography and superb microvascular imaging
    Gunay, Burak
    Solak, Serdar
    Ustabasioglu, Fethi Emre
    Kula, Osman
    Karabulut, Derya
    Tuncbilek, Nermin
    SONOGRAPHY, 2024, 11 (03) : 223 - 230
  • [46] Measuring Shear Wave Velocity in Adult Skeletal Muscle with Ultrasound 2-D Shear Wave Elastography: A Scoping Review
    Stiver, Mikaela L.
    Mirjalili, Seyed Ali
    Agur, Anne M. R.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (06): : 1353 - 1362
  • [47] Multisample Ultrasound Point Shear Wave Elastography of the Liver Repeatability and Agreement With Conventional Point Shear Wave Elastography
    Dillman, Jonathan R.
    Trout, Andrew T.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2023, 42 (12) : 2749 - 2756
  • [48] Changes in ultrasound shear wave elastography properties of normal breast during menstrual cycle
    Rzymski, P.
    Skorzewska, A.
    Opala, T.
    CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, 2011, 38 (02): : 137 - 142
  • [49] Evaluation of renal elasticity by shear wave elastography in children with Familial Mediterranean Fever
    Sav, Nadide Melike
    Altinsoy, Hasan Baki
    Turen, Betul
    Gokce, Ayse
    PEDIATRIC NEPHROLOGY, 2025, : 1701 - 1709
  • [50] Quantifying Myocardial Contractility Changes Using Ultrasound-Based Shear Wave Elastography
    Vejdani-Jahromi, Maryam
    Freedman, Jenna
    Nagle, Matthew
    Kim, Young-Joong
    Trahey, Gregg E.
    Wolf, Patrick D.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2017, 30 (01) : 90 - 96