Ultrasound shear wave elastography for the evaluation of renal pathological changes in adult patients

被引:7
|
作者
Leong, Sook Sam [1 ]
Jalalonmuhali, Maisarah [2 ]
Nazri, Mohammad
Ng, Kwan Hoong [2 ,4 ]
Vijayananthan, Anushya [5 ]
Hisham, Ranitha [6 ]
Wong, Jeannie Hsiu Ding [3 ]
机构
[1] Univ Teknol MARA, Fac Hlth Sci, Ctr Med Imaging Studies, Selangor, Malaysia
[2] Univ Malaya, Fac Med, Dept Med, Kuala Lumpur, Malaysia
[3] Univ Malaya, Fac Med, Dept Biomed Imaging, Kuala Lumpur, Malaysia
[4] UCSI Univ, Fac Med & Hlth Sci, Port Dickson, Negeri Sembilan, Malaysia
[5] Univ Malaya Specialist Ctr, Dept Biomed Imaging, Kuala Lumpur, Malaysia
[6] Univ Malaya, Univ Malaya Lib, Kuala Lumpur, Malaysia
来源
BRITISH JOURNAL OF RADIOLOGY | 2023年 / 96卷 / 1144期
关键词
FORCE IMPULSE QUANTIFICATION; ALLOGRAFT FIBROSIS; ELASTICITY QUANTIFICATION; TISSUE ELASTICITY; KIDNEY; DISEASE; DIAGNOSIS; STIFFNESS; ARFI;
D O I
10.1259/bjr.20220288
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Many studies have conflicting findings in using shear wave elastography (SWE) to assess renal fibrosis. This study reviews the use of SWE to evaluate pathological changes in native kidneys and renal allo-grafts. It also tries to elucidate the confounding factors and care taken to ensure the results are consistent and reliable. Methods: The review was carried out according to the Preferred Reporting Items for SystematicReviews and Meta-Analysis guidelines. Literature search was conducted in Pubmed, Web of Science and Scopus data-base up to 23 October 2021. To evaluate risk and bias applicability, the Cochrane risk -of bias tool and GRADE was used. The review was registered under PROSPERO CRD42021265303.Results: A total of 2921 articles were identified. 104 full texts were examined and 26 studies included in system-atic review. 11 studies performed on native kidneys and 15 studies on transplanted kidney. A wide range of impact factors was found that affect the accuracy of SWE of renal fibrosis in adult patientsConclusions: Compared to point SWE, two-dimensional SWE with elastogram could enable better selection of the region of interest in kidneys, leading to reproducible results. Tracking waves were attenuated as the depth from skin to region of interest increased, therefore, SWE is not recommended for overweight or obese patients. Variable transducer forces might also affect SWE repro-ducibility, thus, training of operators to ensure consistent operator-dependent transducer forces may be helpful. Advances in knowledge: This review provides a holistic insight on the efficiency of using SWE in evaluating pathological changes in native and transplanted kidneys, thereby contributing to the knowledge of its utilisation in clinical practice.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Ultrasound shear wave elastography for the evaluation of renal pathological changes in adult patients
    Barr, Richard G.
    BRITISH JOURNAL OF RADIOLOGY, 2023, 96 (1149):
  • [2] Quantitative evaluation of renal tissue changes in patients with liver cirrhosis by shear wave elastography
    Huizhan Li
    Dianxia Men
    Meihong Jia
    Zhifen Wang
    Wenli Xiao
    Jiping Xue
    Chunsong Kang
    Abdominal Radiology, 2023, 48 : 2085 - 2090
  • [3] Quantitative evaluation of renal tissue changes in patients with liver cirrhosis by shear wave elastography
    Li, Huizhan
    Men, Dianxia
    Jia, Meihong
    Wang, Zhifen
    Xiao, Wenli
    Xue, Jiping
    Kang, Chunsong
    ABDOMINAL RADIOLOGY, 2023, 48 (06) : 2085 - 2090
  • [4] Ultrasound Shear Wave Elastography and Shear Wave Dispersion: Correlation with Histopathological Changes in Autoimmune Hepatitis Patients
    Hazzan, Rawi
    Regev-Sadeh, Tor
    Dola, Tamar
    Shemer-Shamay, Hila
    Umansky, Alona
    Zigmond, Ehud
    Neeman, Ziv
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2025, 51 (05): : 823 - 829
  • [5] Evaluation of renal fibrosis in patients with chronic kidney disease by shear wave elastography: a comparative analysis with pathological findings
    Ziman Chen
    Jiaxin Chen
    Hui Chen
    Zhongzhen Su
    Abdominal Radiology, 2022, 47 : 738 - 745
  • [6] Evaluation of renal fibrosis in patients with chronic kidney disease by shear wave elastography: a comparative analysis with pathological findings
    Chen, Ziman
    Chen, Jiaxin
    Chen, Hui
    Su, Zhongzhen
    ABDOMINAL RADIOLOGY, 2022, 47 (02) : 738 - 745
  • [7] Utility of shear wave ultrasound elastography in evaluation of testicular stiffness in patients with varicocele
    Ahmed Tohamy Ahmed
    Egyptian Journal of Radiology and Nuclear Medicine, 52
  • [8] Utility of shear wave ultrasound elastography in evaluation of testicular stiffness in patients with varicocele
    Ahmed, Ahmed Tohamy
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2021, 52 (01):
  • [9] Ultrasound shear wave elastography and liver biopsy to determine liver fibrosis in adult patients
    Gharibvand, Mohammad M.
    Asare, Mohammad
    Motamedfar, Azim
    Alavinejad, Pezhman
    Momeni, Mohammad
    JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2020, 9 (02) : 943 - 949
  • [10] Correlation of Ultrasound Shear Wave Elastography with Pathological Analysis in a Xenografic Tumour Model
    Eli Elyas
    Efthymia Papaevangelou
    Erwin J. Alles
    Janine T. Erler
    Thomas R. Cox
    Simon P. Robinson
    Jeffrey C. Bamber
    Scientific Reports, 7